Hunter Fanメーカー44377の使用説明書/サービス説明書
ページ先へ移動 of 45
Owner ’ s Manual Model 44372 44377 Form# 44040-01 20100511 ©2010 Hunter Fan Co. English 7 Day Programmable I N S T A L L A T I O N 5 M I N U T E M T W T F S S.
44040-01 • 05/11/2010 2 T able O f Conte nts At A Glance K n o w Y o u r e r m o s t a t .................................................... 3 Setup S e t t i n g D a y a n d T i m e ..................................................... 1 0 Scheduling S c h e d u l i n g I n t r o d u c t i o n .
©2010 Hunte r Fan Company 3 Y our ther mostat has been pre-programmed from the factor y with no programming necessar y . W e recommend using these pre-programmed settings for a few days before altering them as they of fer maximum energy saving benets.
44040-01 • 05/11/2010 4 3 At A Glance 1. Enters Schedule Setup for altering scheduled programs. 2. Sets the Home T oday feature for when you are home during a regularly scheduled Away period. 3. Sets the Save Away feature for when you will not be home during a regularly programmed time.
©2010 Hunte r Fan Company 5 At A Glance 3 Know Y our ermost at 1 8 5 3 2 7 6 11 9 10 6 D one / Ho m e 4.
44040-01 • 05/11/2010 6 1. Holds 2 “AA” Batteries. 2. HE/HG Switch - allows you to set your furnace to Gas/Oil or Electric, based on the type of system you have. 3. Conventional/Heat Pump System Switch - Allows your ther mostat to operate your HV AC system properly by selecting the system type that you have.
©2010 Hunte r Fan Company 7 1 3 2 At A Glance 3 Know Y our ermost at.
44040-01 • 05/11/2010 8 3 At A Glance 1. Shows the current day of the week or weekend. 2. Indicates the ther mostat is running in schedule mode. 3. Flashes when the fur nace lter should be checked for replacement. 4. On when the current schedule period is running.
©2010 Hunte r Fan Company 9 At A Glance 3 Know Y our ermost at o : At Home Auto PM Check H.P .! Hours Aux Em. Energy Savings: Good Best! Lock Mon Filter Heat to C 1 3 5 7 8 9 2 10 14 16 17 19 15 o.
44040-01 • 05/11/2010 10 4 Setup Set ting Da y and Time Once you install the batteries, the thermostat will prompt you to set the current day and time.
©2010 Hunte r Fan Company 11 4 Set ting Da y and Time Setup Done/ Home Menu Back Next Schedule Save Away Home T oday 1-2 Mon : PM Done/ Home Menu Back Next Schedule Save Away Home T oday 5 Updated! D.
44040-01 • 05/11/2010 12 * The schedule time can be set in 15 minute increments, and remains the same for both Heat and Cool programs. * The scheduled temperature can be set in increments of 1°F (1°C). * After 15 minute without a key press, the thermostat will return to the home display screen.
©2010 Hunte r Fan Company 13 5 Personal Scheduling Char ts Schedulin g Day A way Asleep Home Monday-Friday Start Time: 8:00am End Time: 4:00pm Heat T emp: 60 O F (16 O C) Cool T emp: 85 O F (29 O C) .
44040-01 • 05/11/2010 14 5 Schedulin g Set ting Y our Schedule 1. Press the Schedule Button to enter Scheduling mode. 2. Use the or buttons to select “On” and then Next to move for ward to Scheduling. Note: If you do not wish to use the scheduling option on your thermostat, refer to page 22, step 2.
©2010 Hunte r Fan Company 15 5 Set ting Y our Schedule Schedulin g Done/ Home Menu Back Next Schedule Save Away Home T oday 3 Sun Sat Fri Thu Wed T ues Mon Done/ Home Menu Back Next Schedule Save Awa.
44040-01 • 05/11/2010 16 6. Set the temperature for your heating cycle as indicated by the ashing ”Heat to” icon on your screen. Use the and buttons to change the temperature and press Next . Y ou will be asked to set your cooling cycle, indicated by the ashing “Cool to”.
©2010 Hunte r Fan Company 17 5 Set ting Y our Schedule Schedulin g Done/ Home Menu Back Next Schedule Save Away Home T oday 6 Mon Away Asleep At Home o Cool to to AM : : PM Heat to Energy Savings: Go.
44040-01 • 05/11/2010 18 5 Schedulin g Set ting Y our Schedule 10. The day select screen will now show “Copy Day” and ask you if you wish to copy the day you just scheduled to any other days. Select “YES” and Next or see step 13 for selecting “NO”.
©2010 Hunte r Fan Company 19 5 Set ting Y our Schedule Schedulin g Done/ Home Menu Back Next Schedule Save Away Home T oday 10 Mon Copy Day Done/ Home Menu Back Next Schedule Save Away Home T oday 11.
44040-01 • 05/11/2010 20 5 Schedulin g T emporar y T emp eratur e Change With T emporar y T emperature Change you have the ability to alter the temperature for only the current running schedule for one day . 1. Press the or button once to activate the screen, the backlight will come on.
©2010 Hunte r Fan Company 21 5 T emporar y Schedule Change Schedulin g Done/ Home Menu Back Next Schedule Save Away Home T oday 1 Mon At Home o Auto o Heat to Energy Savings: Good Best! : AM Done/ Ho.
44040-01 • 05/11/2010 22 5 Schedulin g T urning O ff Scheduling T o turn of f your schedule and have the thermostat permanently set to one temperature: 1. Press the Schedule button once. 2. Use the or button to switch to Of f and select Done/ Home .
©2010 Hunte r Fan Company 23 5 T urning O ff Scheduling Schedulin g Done/ Home Menu Back Next Schedule Save Away Home T oday 1 Mon At Home o Auto o : AM Heat to Energy Savings: Good Best! Done/ Home.
44040-01 • 05/11/2010 24 5 Schedulin g Home T oday The Home T oday feature allows you to override your schedule for 1 day . It can be used for example if you are home on a day when you would normally have the ther mostat‘s “Away” mode active.
©2010 Hunte r Fan Company 25 5 Home T oday Schedulin g Done/ Home Menu Back Next Schedule Save Away Home T oday 2 Heat to Energy Savings: Good Best! Done/ Home Menu Back Next Schedule Save Away Home .
44040-01 • 05/11/2010 26 5 Schedulin g Save A way The Save Away feature allows you to set a lower or higher temperature for the time you will be away from your home outside of your normal Away schedule. This can include days you will be away for vacation, or a few hours away from your home.
©2010 Hunte r Fan Company 27 5 Save A way Schedulin g Done/ Home Menu Back Next Schedule Save Away Home T oday 2 o Heat to Hours Energy Savings: Good Best! Done/ Home Menu Back Next Schedule Save Awa.
44040-01 • 05/11/2010 28 6 Features Alert s This chapter will outline the various alerts the thermostat will report to you and how to respond to them.
©2010 Hunte r Fan Company 29 6 Alert s Features Done/ Home Menu Back Next Schedule Save Away Home T oday 1b 1a Done/ Home Menu Back Next Schedule Save Away Home T oday 1 Mon At Home Auto PM Heat to E.
44040-01 • 05/11/2010 30 3. Auxiliar y Heat: On multi-stage heat pumps this alert indicates your second stage heat is running. 4. Check System: Some heat pump systems are equipped with the ability to check system performance, indicated by the presence of an “L” wire attached to the mounting plate.
©2010 Hunte r Fan Company 31 6 Alert s Features Done/ Home Menu Back Next Schedule Save Away Home T oday 3 Mon At Home o Auto o PM Heat to Energy Savings: Good Best! Aux Em. : Done/ Home Menu Back Next Schedule Save Away Home T oday 4 Mon At Home o Auto o PM Heat to Energy Savings: Good Best! Check H.
44040-01 • 05/11/2010 32 6 Features Menu Options Under your menu options you have the ability to reset your lter counter , change your day/time , span settings, temperature measurement, as well as locking the thermostat. After making changes to each menu option, the ther mostat will show “Updated” and save your changes.
©2010 Hunte r Fan Company 33 6 Menu Options Features Done/ Home Menu Back Next Schedule Save Away Home T oday 2 Reset Filter Set Day/Time Span 1 Span 2 Span 3 T emp F/C UN Lock Done/ Home Menu Back N.
44040-01 • 05/11/2010 34 5. SP AN 1: The next menu option is to set your ther mostats primar y span. Use the or buttons to adjust between 1, 2, or , 3 degrees. Press Next , the screen will ash “Updated” and return to menu options or press Done/ Home to return to the home screen.
©2010 Hunte r Fan Company 35 6 Menu Options Features Done/ Home Menu Back Next Schedule Save Away Home T oday 5 o Span 1 Done/ Home Menu Back Next Schedule Save Away Home T oday 6a o Span 2 Done/ Hom.
44040-01 • 05/11/2010 36 6 Features Menu Options 1. LOCK/UNLOCK: Allows you to lock the ther mostat so random keypress’ will not change your settings. Use the or buttons to change between “YES” and “NO”. Choose “YES” to lock the thermostat or “NO” to keep the thermostat unlocked.
©2010 Hunte r Fan Company 37 6 Menu Options Features Done/ Home Menu Back Next Schedule Save Away Home T oday 2 Mon At Home o Auto o : PM Heat to Lock Energy Savings: Good Best! Done/ Home Menu Back .
44040-01 • 05/11/2010 38 6 Features Energy S a ver Bar The Energy Saver Bar indicates estimated energy savings. The preset schedules in the thermostat have been designed to give you optimal energy savings, ve bars. Altering these schedules has a direct impact on the energy saver indicator .
©2010 Hunte r Fan Company 39 6 Energy S a ver Bar Features Done/ Home Menu Back Next Schedule Save Away Home T oday 1 Mon At Home o Auto o PM : Heat to Energy Savings: Good Best! Done/ Home Menu Back.
44040-01 • 05/11/2010 40 6 Features Additional Features There is no need to stand at the wall where the ther mostat is mounted while programming or changing settings. Simply remove the thermostat from the wall and make the necessar y changes in the comfort of a chair .
©2010 Hunte r Fan Company 41 7 T roubleshoo ting and Support ermosta t Assistance Problem: No display . Solution: 1. Check batter y position and batter y life. Problem: Program does not change at desired setting. Solution: 1. Check the time in all programs for proper am/pm time.
44040-01 • 05/11/2010 42 Problem: Fan runs continuously . Solution: 1. Check fan setting to see if it is set to on. 2. Move HG/HE switch to opposite position. Problem: Heating or cooling does not turn on or of f. Solution: 1. Check the system is in the right mode (heat or cool).
©2010 Hunte r Fan Company 43 7 T roubleshoo ting and Support ermosta t Assistance If you need any assistance with installion or setup of your new Hunter Thermostat, please call us, our technical s.
44040-01 • 05/11/2010 44 8 W arrant y 1 Y ear Gua rantee Hunter Fan Company Thermostats LIMITED W ARRANTY The Hunter Fan Company warrants your Hunter Thermostat to be free from defects in material or workmanship for a period of one year from the date of sale to the original user or consumer purchaser .
©2010 Hunte r Fan Company 45 Suite 400, Memphis, TN 38016. Y ou will be responsible for all insurance and freight or other transportation charges to our factor y .
デバイスHunter Fan 44377の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Hunter Fan 44377をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはHunter Fan 44377の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Hunter Fan 44377の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Hunter Fan 44377で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Hunter Fan 44377を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はHunter Fan 44377の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Hunter Fan 44377に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちHunter Fan 44377デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。