AquaSaver ® DISPOSER CONTROL CENTER Installation Manual Model AS-101K Please be certain that the person who installs or uses this appliance carefully r eads and understands the Safety Instructions contained in this manual. The Danger signal indicates an immediately hazardous situation which, if not avoided, will result in death or serious injury .
2 T able of Contents Introduction/Featur es Introduction ..................................................................................... 3 Features .......................................................................................... 3 Mounting The Control Center/Plumbing Connections Mounting the Control Center .
3 NOTE: When the disposer is first turned on, both solenoids will operate. After the set time has expired, the flow to the disposer will slow to one gallon per minute if there is not food waste present in the grinding chamber .
4 Mounting the Control Center/Plumbing Connections MOUNTING THE CONTROL CENTER Use the flanges at the back of the control center enclosure and only mount panel in the upright vertical position (door hinge is on the left). See Figure 1. Locate control center within sight of disposer per local codes.
5 24V Water Solenoid 1 GPM Flow Control 24V Water Solenoid 7 GPM Flow Control 2 3 4 6 7 7 13 Disposer 14 M1/M3 M4/M6 M2 M5 M7 NC NC 1 3 2 L1 L2 L1 L2 On Off Neutral Hot Pre-wired in panel to contactors Power Supply Motor Leads Panel Ground Lug Control Center Connection To Power Supply 4 6 5 7 Figure 3.
6 PERSONAL INJURY • Allow only trained personnel to operate disposer . • Use baffles and guarding to avoid splashing and ejection of materials. • Do not put fingers or hands into the disposer . • When attempting to remove objects fr om a disposer , use long-handled tongs or pliers.
7 Figure 9. OPERA TING INSTRUCTIONS TO ST AR T 1. Check to ensure disposer is fr ee of foreign objects. 2. Ensure power is on. 3. Push start button. Disposer motor will run and water will flow into the disposer . 4. W ater flow will decrease to 1 GPM appr oximately 30 seconds after intitial start-up if no load is present in disposer .
8 This control center was inspected and tested under operating conditions before shipment fr om the factory . In case of trouble, check the items listed below . A. Disposer motor will not start and water does not flow . 1. No incoming line power , turn line power on.
9 120 V 1-phase 1/2 to 2 HP (FNA2) 2 3 4 6 7 M1 M3 M2 M4 M6 4 M1 M4 6 11 9 4 L1 L2 9 7 7 11 12 13 2 4 4 L1 L2 INCOMING POWER P ANEL GROUND LUG GROUND 6 6 6 3 7 L1 L2 4 4 2 10 7 STOP ST ART 12 10 X2 24.
10 AS-101K-2 Wiring Diagram 208/230 V 1-phase 1/2 to 2 HP (FNA2) 2 3 4 6 7 M3 M4 4 M1 M4 6 11 9 4 L1 L2 9 7 7 11 12 13 2 4 4 L1 L2 INCOMING POWER GROUND 6 6 6 3 7 L1 L2 4 4 2 10 7 STOP ST ART 12 10 X2.
11 208/230 V 3-phase 1/2 to 10 HP (FNA2) 4 24V W A TER SOLENOID V AL VE MOUNT IN LINE 7 GPM FLOW CONTROL L2 L2 M3 M2 M1 TRIP POINT TRIP DELA Y 14 7 7 4 5 4 3 2 1 AC CURRENT SENSOR OFF ON H4 H2 H3 H1 X.
12 AS-101K-4 Wiring Diagram 380/460 V 3-phase 1/2 to 10 HP (FNA2) 24V W A TER SOLENOID V AL VE MOUNT IN LINE FLOW CONTROL L2 L2 M3 M2 M1 TRIP POINT TRIP DELA Y 14 7 7 4 5 4 3 2 1 AC CURRENT SENSOR H4 .
デバイスInSinkErator AS-101Kの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
InSinkErator AS-101Kをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはInSinkErator AS-101Kの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。InSinkErator AS-101Kの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。InSinkErator AS-101Kで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
InSinkErator AS-101Kを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はInSinkErator AS-101Kの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、InSinkErator AS-101Kに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちInSinkErator AS-101Kデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。