L440GX+ Server Board Product Guide Order Number: 722077-005.
Disclaimer Intel Corporation (Intel) makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Intel assumes no responsibility for any errors that may appear in this document.
iii Contents 1 Description Server Board Features .......................................................................................................... 7 Back Panel Connectors .......................................................................
iv Contents Setup Menus .............................................................................................................. 36 Main Menu .......................................................................................................
L440GX+ Server Board Product Guide v 4 Solving Problems Resetting the System .......................................................................................................... 85 Fault Resilient Booting ........................................
vi Contents Ensure Host Computer and Accessory Module Certifications ................................... 107 Prevent Power Supply Overload ............................................................................... 107 Place Battery Marking on Computer .
7 1 Description Server Board Features Table 1 . Server Board Features Feature Description Processor Installed: Up to two Intel ® Pentium ® II or Pentium III processors (with 100 MHz system bus) operating at 1.
8 Description Back Panel Connectors Figure 1 . Back Panel Connectors A. Mouse connector B. Keyboard connector C. Parallel Port connector D. Serial Port connectors E. Network connector F. Green NIC LED G. Orange NIC LED H. USB connectors I. Video connector Table 2 .
L440GX+ Server Board Product Guide 9 Server Board Connector and Component Locations Figure 2 . Server Board Connector and Component Locations A. Fansink connector 2 B. Secondary processor C. Fansink connector 1 D. Primary processor E. DIMM slots F. Main power connector G.
10 Description Processor Each Pentium II or Pentium III processor is packaged in a cartridge. The cartridge includes the processor core with an integrated 16 KB primary (L1) cache, the secondary (L2) cache, and a back cover.
L440GX+ Server Board Product Guide 11 / NOTE Use DIMMs that have been tested for compatibility with the server board. Contact your sales representative or dealer for a current list of approved memory modules. Check the Intel Customer Support website for the latest tested memory list: http://support.
12 Description Add-in Board Slots The server board has one full length ISA bus connector. ISA features: • Bus speed up to 8.33 MHz • 16 bit memory addressing • Type A transfers at 5.
L440GX+ Server Board Product Guide 13 Video The onboard, integrated Cirrus Logic CL-GD5480 64 bit VGA chip contains an SVGA controller that is fully compatible with these video standards: CGA, EGA, Hercules † Graphics, MDA, and VGA. The standard configuration comes with 2 MB of 10 ns onboard Synchronous Graphics Memory (SGRAM).
14 Description / NOTE 18 inch maximum length of IDE cable on each channel: You can connect an IDE signal cable, up to a maximum of 18 inches each, to each IDE connector on the server board. Each cable c an support two devices, one at the end of the cable and one 6 inches from the end of the cable.
L440GX+ Server Board Product Guide 15 future versions of Microsoft Windows NT † x that support ACPI, the BIOS will support sleep states s0, s1, s4, and s5. • s0: Normal running state. • s1: Processor sleep state. No context will be lost in this state and the processor caches will maintain coherency.
16 Description • Monitors the SDR/SEL timestamp clock • Manages the server board Field Replaceable Unit (FRU) information interface • Monitors the system management watchdog timer • Monitors t.
L440GX+ Server Board Product Guide 17 Security To help prevent unauthorized entry or use of the server, Intel Server Control server management software monitors the system intrusion switch. Security with Mechanical Locks and Monitoring If installed, you can activate the chassis intrusion alarm switch.
18 Description • May enter either password to boot the server if Password on Boot is enabled in either the BIOS Setup or SSU. • May enter either password to exit secure mode.
L440GX+ Server Board Product Guide 19 Summary of Software Security Features The table below lists the software security features and describes what protection each offers. In general, to enable or set the features listed here, you must run the SSU and go to the Security Subsystem Group, menu.
20 Description Table 3 . Software Security Features (continued) Feature Description Control access to the system other than SSU: set user password To control access to using the system, set a user password and enable it through Setup or the SSU.
21 2 Upgrading Tools and Supplies Needed • Phillips (cross head) screwdriver (#1 bit and #2 bit) • Jumper removal tool or needle nosed pliers • Pen or pencil • Antistatic wrist strap and conductive foam pad (recommended) Warnings and Cautions These warnings and cautions apply throughout this chapter.
22 Upgrading top that you can grip with your fingertips or with a pair of fine needle nosed pliers. If your jumpers do not have such a tab, take care when using needle nosed pliers to remove or install a jumper; grip the narrow sides of the jumper with the pliers, never the wide sides.
L440GX+ Server Board Product Guide 23 Figure 3 . Server Board Screw Hole Locations Removing the Server Board CAUTION The server board can be extremely sensitive to ESD and always requires careful handling. After removing it from the server, place it component side up on a nonconductive, static free surface to prevent shorting out the battery leads.
24 Upgrading Memor y Installing DIMMs CAUTIONS Use extreme care when installing a DIMM. Applying too much pressure can damage the socket. DIMMs are keyed and can be inserted in only one way. Mixing dissimilar metals may cause later memory failures resulting in data corruption.
L440GX+ Server Board Product Guide 25 Figure 4 . Installing DIMMs Removing DIMMs CAUTION Use extreme care when removing a DIMM. Too much pressure can damage the socket slot. Apply only enough pressure on the plastic ejector levers to release the DIMM.
26 Upgrading Processors WARNING If the server has been running, any installed processor and heat sink on the processor board(s) will be hot. To avoid the possibility of a burn, be careful when removing or installing server board components that are located near processors.
L440GX+ Server Board Product Guide 27 CAUTION This is a difficult process. Do not pull the tab of the retention mechanism back too far, as damage to either the retention mechanism or server board can occur. Pull the tab of the retention mechanism back just far enough for the retention lock to free the processor.
28 Upgrading Installing a Processor 1. Observe the safety and ESD precautions at the beginning of this chapter and the additional cautions given here. 2. If your server has one processor and you are ADDING a second, then you must remove the termination card from the secondary processor slot.
L440GX+ Server Board Product Guide 29 3. If your server has one processor and you are REPLACING it, leave the termination board intact in the empty secondary slot. Remove the processor you want to replace. See “Removing a Processor” on page 26 . 4.
30 Upgrading Replacing the Back up Battery The lithium battery on the server board powers the real time clock (RTC) for up to 10 years in the absence of power. When the battery starts to weaken, it loses voltage, and the server settings stored in CMOS RAM in the RTC (for example, the date and time) may be wrong.
L440GX+ Server Board Product Guide 31 Figure 7 . Replacing the Lithium Battery 1. Observe the safety and ESD precautions at the beginning of this chapter. 2. Open the chassis. 3. Insert the tip of a small flat bladed screwdriver, or equivalent, under the tab in the plastic retainer.
32 Upgrading.
33 3 Configuration Software and Utilities This chapter describes the Power On Self Test (POST) and server configuration utilities. The table below briefly describes the utilities.
34 Configuration Software and Utilities Power On Self Test (POST) Each time you turn on the system, POST starts running. POST checks the server board, processor, memory, keyboard, and most installed peripheral devices. During the memory test, POST displays the amount of memory that it is able to access and test.
L440GX+ Server Board Product Guide 35 Using BIOS Setup This section describes the BIOS Setup options. Use Setup to change the server configuration defaults. You can run Setup with or without an operating system being present. Setup stores most of the configuration values in battery backed CMOS; the rest of the values are stored in flash memory.
36 Configuration Software and Utilities Starting Setup You can enter and start Setup under several conditions: • When you turn on the server, after POST completes the memory test • When you reboot.
L440GX+ Server Board Product Guide 37 Main Menu You can make the following selections on the Main Menu itself. Use the submenus for other selections. Feature Choices Description System Time HH:MM:SS Sets the system time. System Date MM/DD/YYYY Sets the system date.
38 Configuration Software and Utilities Primary/Secondary IDE Master and Slave Submenu Feature Choices Description Type Auto None CD-ROM IDE Removable ATAPI Removable User Auto forces the server to attempt autodetection of the drive type. None informs the server to ignore this drive.
L440GX+ Server Board Product Guide 39 Keyboard Submenu Feature Choices Description Num Lock On Off Selects the power on state for Num Lock. Key Click Disabled Enabled Enables or disables the audible key click. Keyboard auto-repeat rate 30/sec 26.7/sec 21.
40 Configuration Software and Utilities Advanced Menu You can make the following selections on the Advanced Menu itself. Use the submenus for the three other selections that appear on the Advanced Menu. Feature Choices Description Installed OS Other Win95 Select Win95 if you are booting a Plug and Play capable operating system.
L440GX+ Server Board Product Guide 41 PCI Device, Slot 1 - Slot 6 Submenus Feature Choices Description Enable Master Enabled Disabled Enables selected device as a PCI bus master. Latency Timer Default 020h 040h 060h 080h 0A0h 0C0h 0E0h Minimum guaranteed time, in units of PCI bus clocks, that a device may be master on a PCI bus.
42 Configuration Software and Utilities Integrated Peripheral Configuration Submenu (continued) Feature Choices Description Interrupt IRQ 5 IRQ 7 Selects the IRQ for LPT port. DMA channel DMA 1 DMA 3 Selects the DMA for LPT port (only used for ECP mode).
L440GX+ Server Board Product Guide 43 Security Menu You can make the following selections on the Security Menu itself. Enabling the Supervisor Password field requires a password for entering Setup. The passwords are not case-sensitive. Feature Choices Description User Password is Clear Set Status only; user cannot modify.
44 Configuration Software and Utilities Server Menu You can make the following selections on the Server Menu itself. Feature Choices Description System Management Enters submenu.
L440GX+ Server Board Product Guide 45 System Management Submenu (continued) Feature Choices Description EMP Hangup Line String ATH Sets the Hangup Line Sequence for the modem being used for EMP. Used in EMP modem mode. Modem Init String AT&F0S0=1S14=0&D Sets the initialization string for the modem being used for EMP.
46 Configuration Software and Utilities Console Redirection Submenu Feature Choices Description COM Port Address Disabled 3F8 2F8 3E8 When enabled, console redirection uses the I/O port specified. 3F8 - typically is COM1 2F8 - typically is COM2 All keyboard/mouse and video will be directed to this port.
L440GX+ Server Board Product Guide 47 PEP Management Submenu Verify in BIOS Setup of your server board whether or not your system BIOS includes PEP. If not, when it becomes available, you can download it from the Intel Customer Support website: http://support.
48 Configuration Software and Utilities PEP Filter Submenu This submenu allows you to set which events or error conditions cause the system to page you.
L440GX+ Server Board Product Guide 49 Extended RAM Step Choice Description 1 MB Tests extended memory once per MegaByte 1 KB Tests extended memory once per KiloByte Every Location Tests all extended m.
50 Configuration Software and Utilities Removable Devices For options on this menu, use the up or down arrow keys to select a device, then press the <+> or < - > keys to move the device higher or lower in the boot priority list. Option Description 1.
L440GX+ Server Board Product Guide 51 When to Run the System Setup Utility The SSU is a DOS-based utility that supports extended system configuration operations for onboard resources and add-in boards. You can also view the system event log and to set system boot and security options.
52 Configuration Software and Utilities Running the SSU • Running the SSU Locally Running the ssu.bat file provided on the SSU media starts the SSU. If the server boots directly from the SSU media, the ssu.bat file is automatically run. If it boots from a different media, the SSU can be started manually or by another application.
L440GX+ Server Board Product Guide 53 5. This message appears: Please wait while the Application Framework loads.... 6. When the main window of the SSU appears, you can customize the user interface before continuing.
54 Configuration Software and Utilities Customizing the SSU The SSU lets you customize the user interface according to your preferences. The AF sets these preferences and saves them in the AF.INI file so that they take effect the next time you start the SSU.
L440GX+ Server Board Product Guide 55 Resource Configuration Add-in (RCA) Window The RCA provides three major functions: • Creates representations of devices that cannot be di s covered by the syste.
56 Configuration Software and Utilities Adding and Removing ISA Cards Adding and removing cards through the RCA provides a way for the RCA to run its conflict detection algorithms on the resources requested by the cards. This alerts you to any possible problems with that particular card in the current configuration.
L440GX+ Server Board Product Guide 57 Security Add-in Under this window, you can set the User and Administrator passwords, and security options. To Set the User Password 1. Click on the user password button. 2. Enter the password in the first field. 3.
58 Configuration Software and Utilities SEL Manager Add-in Clicking on the SEL Manager Add-in task brings up the Server Event Log (SEL) viewer. You can load and view the current SEL data stored in the BMC, save the currently loaded SEL data to a file, view previously saved SEL data, or clear the SEL.
L440GX+ Server Board Product Guide 59 FRU Manager Add-in Clicking on the FRU Manager Add-in task brings up the Field Replaceable Unit (FRU) viewer. You can load and view the current FRU data stored in the BMC, save the currently loaded FRU data to a file, view previously saved FRU data.
60 Configuration Software and Utilities SDR Manager Add-in Clicking on the SDR Manager Add-in task brings up the Sensor Data Record (SDR) viewer. You can load and view the current SDR data stored in the BMC, save the currently loaded SDR data to a file, view previously saved SDR data.
L440GX+ Server Board Product Guide 61 Platform Event Paging With Platform Event Paging (PEP), your server can be configured to automatically dial up a paging service and page you when a server management related event occurs. Platform events include temperature out-of-range, voltage out-of-range, chassis intrusion, and fan failure.
62 Configuration Software and Utilities Emergency Management Port Console The Emergency Management Port (EMP) Console is a software application designed to run on a Windows 95 or Windows NT 4.0 workstation and provides a server administrator’s interface to the Emergency Management Port (EMP) of the L440GX+ server.
L440GX+ Server Board Product Guide 63 How EMP Console Works The EMP shares use of the COM2 port with the system on the server. When the EMP has control of the port, the port operates in command mode. When the system has control, the port operates in console redirect mode.
64 Configuration Software and Utilities Figure 10 . EMP Console in Redirect State Figure 10 shows EMP Console window in redirect mode with the terminal window.
L440GX+ Server Board Product Guide 65 Table 7 . EMP Console Access Modes (Server not configured for console redirection) Mode Server is powered off During BIOS POST After OS boots Disabled Redirect wi.
66 Configuration Software and Utilities Setting up the Server for the EMP To use the EMP, you must configure the server's BIOS with specific settings. These settings are found in two submenus of the BIOS Server menu, the System Management Submenu and the Console Redirection submenu.
L440GX+ Server Board Product Guide 67 Main EMP Console Window The main EMP Console window provides a graphical user interface (GUI) to access server control operations and to launch the management plug-ins. At the top of the window is the menu and tool bar.
68 Configuration Software and Utilities EMP Console Main Menu • File Exit - exits EMP Console. • Connect Disconnect - disconnects the server connection. [Re]Connect - displays the connect dialog. A list of the five most recent modem connections.
L440GX+ Server Board Product Guide 69 Connect When [Re]Connect is selected from the Connect menu, the Connect dialog in Figure 11 is displayed. This dialog allows you to connect to a server. If the client machine is already connected to a server, initiating connection generates a warning message.
70 Configuration Software and Utilities Power On/Off Selecting Power On/Off from the Action menu displays the Power on/off dialog. This dialog provides commands to remotely power on or power off the server. Figure 12 . Power On/Off Dialog Options available in the dialog are: • Power ON - powers on the server.
L440GX+ Server Board Product Guide 71 Options available in the dialog are: • System Reset - resets the server with the selected post-reset options. This operation is not allowed if the server is configured in RESTRICTED mode for EMP operations. • Post-reset option - sets the post-reset option that will be in effect after reset.
72 Configuration Software and Utilities • Connect - displays the Connect dialog with the server from the Phonebook's Server dropdown list box already populating the Connect dialog's Server field. • Cancel - exits the Connect dialog without taking any action.
L440GX+ Server Board Product Guide 73 By Event - displays all the events in the SEL of a particular event type; for example, threshold, digital, or discrete. A pop-up menu lets you select the event type to be displayed. Settings - changes several operating parameters for the SEL Viewer.
74 Configuration Software and Utilities FRU Viewer The FRU Viewer allows you to view the server's FRU (Field Replaceable Unit) data from the server's Front Panel FRU information area.
L440GX+ Server Board Product Guide 75 FRUSDR Load Utility The Field Replacement Unit (FRU) and Sensor Data Record (SDR) Load Utility is a DOS-based program used to update the server management subsystem’s product level FRU, SDR, and the Desktop Management Interface (DMI) nonvolatile storage components (EEPROMs).
76 Configuration Software and Utilities How You Use the FRUSDR Load Utility This utility is compatible with ROM-DOS Ver. 6.22, MS-DOS † Ver. 6.22, and later versions. The utility accepts CFG, SDR and FRU load files. The executable file for the utility is frusdr.
L440GX+ Server Board Product Guide 77 Displaying DMI Area The DMI area is displayed in ASCII format when the field is ASCII or as a number when the field is a number. Each DMI area displayed is headed with the DMI area designated name. Each field has a field name header followed by the field in ASCII or as a number.
78 Configuration Software and Utilities Updating the SDR Nonvolatile Storage Area After the utility validates the header area of the supplied SDR file, it updates the SDR repository area. Before programming, the utility clears the SDR repository area.
L440GX+ Server Board Product Guide 79 Upgrading the BIOS Preparing for the Upgrade Before you upgrade the BIOS, prepare for the upgrade by recording the current BIOS settings, obtaining the upgrade utility, and making a copy of the current BIOS. Recording the Current BIOS Settings 1.
80 Configuration Software and Utilities Creating the BIOS Upgrade Floppy Diskette The BIOS upgrade file is a compressed self-extracting archive that contains the files you need to upgrade the BIOS. 1. Copy the BIOS upgrade file to a temporary directory on your hard disk.
L440GX+ Server Board Product Guide 81 Recovering the BIOS It is unlikely that anything will interrupt the BIOS upgrade; however, if an interruption occurs, the BIOS could be damaged. The following steps explain how to recover the BIOS if an upgrade fails.
82 Configuration Software and Utilities Using the Firmware Update Utility The Firmware Update Utility is a DOS-based program used to update the Baseboard Management Controller’s firmware code. You only need to run the Firmware Update Utility if new firmware code becomes necessary.
L440GX+ Server Board Product Guide 83 Using the Adaptec SCSI Utility The Adaptec SCSI utility detects the SCSI host adapters on the server board. The utility runs out of BIOS and is used to • Change default values • Check and/or change SCSI device settings that may conflict with those of other devices in the server Running the SCSI Utility 1.
84 Configuration Software and Utilities.
85 4 Solving Problems This chapter helps you identify and solve problems that might occur while you are using the system. Resetting the System To do this: Press: Soft boot reset, which clears system memory and reloads the operating system. <Ctrl+Alt+Del> Clear system memory, restart POST, and reload the operating system.
86 Solving Problems Checklist q Are all cables correctly connected and secured? q Are the processors or processor termination board fully seated in their slots on the server board? q Are all add-in IS.
L440GX+ Server Board Product Guide 87 After the System Has Been Running Correctly Problems that occur after the system hardware and software have been running correctly often indicate equipment failure. Many situations that are easy to correct, however, can also cause such problems.
88 Solving Problems More Problem Solving Procedures This section provides a more detailed approach to identifying a problem and locating its source. Preparing the System for Diagnostic Testing CAUTION.
L440GX+ Server Board Product Guide 89 Specific Problems and Corrective Actions This section provides possible solutions for these specific problems: • Power light does not light. • There is no beep or an incorrect beep pattern. • No characters appear on screen.
90 Solving Problems 3. If there are still no characters on the screen after you reboot the system and POST emits a beep code, write down the beep code you hear. This information is useful for your service representative. See “ Port-80 Codes and Countdown Codes ” on page 94 .
L440GX+ Server Board Product Guide 91 Diskette Drive Activity Light Does Not Light Check the following: q Are the diskette drive power and signal cables properly installed? q Are all relevant switches.
92 Solving Problems / NOTE Front panel hard disk LED indicates IDE and SCSI devices : The hard disk drive activity light on the front panel lights when either an IDE hard disk drive, or a SCSI device controlled by the onboard SCSI host controller, is in use.
L440GX+ Server Board Product Guide 93 The controller stopped working when an add-in adapter was installed. q Make sure the cable is connected to the port from the onboard network controller. q Make sure your PCI BIOS is current. Try the “PCI Installation Tips” below.
94 Solving Problems Error and Informational Messages When you turn on the system, POST displays messages that provide information about the system. If a failure occurs, POST emits beep codes that indicate errors in hardware, software, or firmware.
95 5 Technical Reference This chapter includes the following: • Environmental specifications • Board interrupts • Electromagnetic Compatibility (EMC) notices.
96 Technical Reference Connectors The figure shows connector locations on the server board. This section provides pin information about the connectors. Figure 15 . Connector Locations A. Fansink connector 2 I. ISOL IMB B. Fansink connector 1 J. Fan connector 1 C.
L440GX+ Server Board Product Guide 97 ATX Style Front Panel Connector Figure 16 . ATX Style Front Panel Connector Table 8 . ATX Style Front Panel Connector Pinout Connector Pin Signal A. Power switch 1 2 3 Power switch GND N/C B. Hard drive activity LED 4 5 6 7 Current limited +5V Key HD activity LED Current limited +5V C.
98 Technical Reference Main Power Connector Table 9 . Main Power Connector Pinout Pin Signal Pin Signal 1 +3.3V 13 +3.3V 2 +3.3V 14 -12V 3 COM 15 COM 4 +5V 16 PS_ON 5 COM 17 COM 6 +5V 18 COM 7 COM 19 COM 8 PWR_OK 20 -5V 9 +5VSB 21 +5V 10 +12V 22 +5V 11 +12V 23 +5V 12 +3.
L440GX+ Server Board Product Guide 99 Server Board Jumpers Figure 17 . Jumper Locations Table 11 . Server Board Jum per Summary Jumper Block Jumper Name Pins (default in bold) What it does at system reset J5A2 WOL ENABLE 1-2, Disabled Disables Wake On LAN.
100 Technical Reference Table 11 . Server Board Jumper Summary (continued) Jumper Block Jumper Name Pins (default in bold) What it does at system reset J2J1 CMOS CLR 1-2, Protect Preserves the contents of NVRAM. 2-3, Erase Replaces the contents of NVRAM with the manufacturing default settings.
L440GX+ Server Board Product Guide 101 CMOS Jumper The jumper at pins 1, 2, and 3 controls whether settings stored in CMOS nonvolatile memory (NVRAM) are retained during a system reset. Procedure to restore the system’s CMOS and RTC to default values: 1.
102 Technical Reference Recovery Boot Jumper The jumper at pins 9, 10, and 11 controls whether the system attempts to boot using the BIOS programmed in the boot block area of the FLASH memory. This should be used only if the operational area of the BIOS is corrupted or needs to be upgraded.
L440GX+ Server Board Product Guide 103 Procedure to permit boot block erasing and programming: 1. See “ General Procedure to Change Jumper Setting ” on page 100 . 2. Move the boot block jumper from pins 13 and 14 to pins 14 and 15 to erase and program the BIOS boot block.
104 Technical Reference.
105 6 Regulatory and Integration Information Regulatory Compliance This server baseboard complies with the following safety and EMC regulations when correctly installed in a compatible host system.
106 Regulatory and Integration Information Installation Instructions CAUTION Follow these guidelines to meet safety and regulatory requirements when installing this board assembly. Read and adhere to all of these instructions and the instructions supplied with the host computer and associated modules.
L440GX+ Server Board Product Guide 107 Ensure Host Computer and Accessory Module Certifications Make sure that the host computer, any added subassembly (such as a board or drive assembly, including internal or external wiring), are certified for the region(s) where the end product will be used.
108 Regulatory and Integration Information Place Battery Marking on Computer There is insufficient space on this server board to provide instructions for replacing and disposing of the battery. The following warning must be placed permanently and legibly on the host computer as near as possible to the battery.
109 7 Equipment Log and Power Consumption Worksheets Equipment Log Use the blank equipment log provided here to record information about your system. You will need some of this information when you run the SSU.
110 Equipment Log and Power Consumption Worksheets Equipment Log (continued) Item Manufacturer Name and Model Number Serial Number Date Installed.
L440GX+ Server Board Product Guide 111 Current Usage As an overall current usage limitation on the power supply, do not exceed a combined power output of 167 watts for the +5 and +3.3 volt outputs. The ISA slots on the server board are rated at a maximum of 4.
112 Equipment Log and Power Consumption Worksheets Worksheet, Calculating DC Power Usage 1. List the current for each board and device in the appropriate voltage level column. 2. Add the currents in each column. Then go to the next worksheet. Table 14 .
L440GX+ Server Board Product Guide 113 Worksheet, Total Combined Power Used by the System 1. From the previous worksheet, enter the total current for each column. 2. Multiply the voltage by the total current to get the total wattage for each voltage level.
114 Equipment Log and Power Consumption Worksheets.
L440GX+ Server Board Product Guide 115 Index A Add-in boards IDE bus slots, 12 ISA, 51 ISA slots, 12 PCI, 51 administrative password, 17 limiting access to SCU, 19 Advanced Menu, configuring in Setup,.
116 Index D diagnostics, preparing system for testing, 88 DIMM (memory) installing, 24 removing, 25 diskette drive controller, 13 enabling/disabling floppy writes, 19 no booting in secure mode without.
L440GX+ Server Board Product Guide 117 M - N Main power supply, connector, 98 memory amount tested, POST, 34 capacity, 7 DIMM requirements, 11 DIMM size, 10 expansion, 10 installing DIMM, 24 removing .
118 Index S SCI files, 51 SCSI, bus termination requirements, 13 SCSI controller, 13 SCU administrative password limits access to, 19 changing configuration, 33 diskette drive required to run SCU, 33 .
L440GX+ Server Board Product Guide 119 System setup utility CFG files, 51 customizing, 54 defining an ISA card, 55 exiting, 60 launching a task, 54 location, 50 removing an ISA card, 56 running, 52 lo.
120 Index.
デバイスIntel L440GXの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Intel L440GXをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはIntel L440GXの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Intel L440GXの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Intel L440GXで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Intel L440GXを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はIntel L440GXの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Intel L440GXに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちIntel L440GXデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。