KTI NetworksメーカーKGD-600の使用説明書/サービス説明書
ページ先へ移動 of 53
-1- K GD-600 Industrial Web Smart 6-Port Giga bit Ethernet Switch with Fiber Connectivity In stallation Guide DOC.070402.
-2- (C) 2006 KTI Networks Inc. All rights reserved. No part of this documentation may be reproduced in any form or by any means or used to make any directive work (such as translation or transformation) without permission from KTI Networks Inc. KTI Networks Inc.
-3- The information contained in this document is subject to change without prior notice. Copyright (C) . All Rights Reserved. TRADEMARKS Ethernet is a registered trademark of Xerox Corp. W ARNING: This equi pment ha s been tested a nd found to comply with the li mits f or a Cla ss A digital device, pursua nt to Part 15 of the FCC Rules.
-4- T a ble of Contents 1. Introduction .................................................................................................. 6 1.1 Features .................................................................................................
-5- 4. Web Ma n age ment ....................................................................................... 27 4.1 Start Browser Software a nd M a king Connection ..................................................... 27 4.2 Login to the Switch U nit .
-6- 1. Introduction The KGD-600 is a ma naged 6-port Giga bit Ethernet switch which is featured with five copper ports, one mini-GBIC (SFP) port a nd the f ollowing a dva ntage s in a small footprint box: Plug a nd Play The switch is shi pped with factory default configuration which behave s like a n unma naged Giga bit switch for workgroup.
-7- Industrial Features For industri al environment, the devices are designed with the following enha nced features exceeding that of commerci al Ethernet switches: • High a nd wide operating T empe.
-8- 1.2 Product Pa nels The following figure illustrates the fa c es of the switch:.
-9- 1.3 LED Indicators LED Function POWER Power status LN K/1000M/ACT Network port 1000M link status (Port 1 - Port 5) LNK/100M/ACT Network port 100M link status (Port 1 - Port 5) LNK/10M/ACT Network port 10M link status (Port 1 - Port 5) P6 LNK Port 6 1000M link status P6 OL Port 6 optical link status 1.
-10- Port control Port configuration control vi a software ma nagement Port M irroring M irror received fra mes to a sniffer port Softwar e M a nage ment Functions Interfa ces W e b browser M a nageme.
-11- 2. In stallation 2.1 Un pa cking The product pa ckage contains: • The switch unit • One product CD-ROM 2.2 Safety Cautions T o reduce the risk of bodily injury , electrical shock, fire, a nd da mage to the product, observe the following precautions.
-12- 2.4 Din-Rail Mounting The steps to mount the switch on a Din-rail are: One Din-rail mounting bra cket is provided in the product pa ckage a s shown below: Install the bra cket on the bottom of the switch unit.
-13- 2.5 Pa nel Mounting One pa nel mounting bra cket is provided in the product pa ckage a s shown below: Install the bra cket on the bottom of the switch unit.
-14- 2.6 Applying Power The switch provides two types of power interfa ces, terminal block a nd DC power ja ck f or rece iving DC power input from external power supply system.
-15- Using DC Power Ja ck When a n external power system is not availa ble, the switch provides a DC ja ck to rece ive power from typical AC-DC power a d a pter alternatively . AC Power Ada pters: Optional commerci al rated a da pters are availa ble for purcha sing.
-16- 2.8 Ma king UTP Connection s The 10/100/1000 copper ports support the following connection type s a nd dista nces: Network Cables 10BASE-T : 2-pair UTP Cat. 3,4,5 , EIA/TIA-568B 100-ohm 100BASE-TX: 2-pair UTP Cat. 5, EIA/TIA-568B 100-ohm 1000BASE-T : 4-pair UTP Cat.
-17- 2.9 M a king Fiber Connection The mini-GBIC (SFP) port must be installed with a n SFP fiber tra nsceiver f or making fiber connec- tion. Y our switch may come with a n SFP tra nsceiver pre-installed when it is shi pped. Installing SFP Fiber T ra nsceiver T o install a n SFP fiber tra nsce iver into mini-GBIC port, the ste ps are: 1.
-18- 2.10 LED Indication L ED Function State Interpretation POWER Power status O N The power is supplied to the switch. OFF The power is not supplied to the switch. LNK/1000M/ACT Port link status O N A 1000M link is established. (No traffic) BLINK Port link is up and there is traffic.
-19- 3. Advanced Functions T o help a better understa nding a bout the software ma nage ment interfa ces, this cha pter describes some advanced functions provided by the switch. 3.1 Abbreviation Ingress Port : Ingress port is the input port on which a packet is received.
-20- 3.2 QoS Function The switch provides a powerful Quality of Service (QoS) function to guide the packet forwarding in four priority classes. The versatile classification methods can meet most of the application needs.
-21- 3.2.1 Packet Priority Classification Each received packet is examined and classified into one of four priority classes, Class 3, Class 2, Class 1 and Class 0 upon reception. The switch provides the following classification methods: 802.1p classification : use User Priority tag value in the received IEEE 802.
-22- 3.3 VLAN Function The switch supports port-ba sed VLAN, 802.1Q T ag VLAN a nd eight VLAN groups. 3.3.1 VLAN Operation The following figure illustrates the basic VLAN operation flow beginning from a packet received on an ingress port until it is transmitted from an egress port.
-23- 3.3.2.3 Drop Untag Per Port Setting Enable - All untagged packets and priority-tagged packets are dropped. A priority-tagged packet is treated as an untagged packet in this switch. Only VLAN-tagged packets are admitted. Disable - Disable Untagged packet filtering 3.
-24- 3.3.5 VLAN Group T a ble Configuration The switch provides a ta ble of eight VLAN groups to support up to eight VLANs at the same ti me. Each VLAN group is associated to one unique VLAN.
-25- 3.3.8 Egre ss T agging Rules Egress T agging rules are used to make cha nge to the pa cket bef ore it is stored into egress queue of a n egress port.
-26- 3.4 802.1X Authentication Port Access Control For some IEEE 802 LAN environments, it is desira ble to restrict a cce ss to the services of fered by the LAN to those users a nd devices that are permitted to make use of those services.
-27- 4. W eb Ma n age ment The switch features a n http server which ca n serve the ma nagement requests coming from a ny web browser software over TCP/IP network. W eb Br owser Compatible web browser software with JA V A scri pt support M icrosoft Internet Explorer 4.
-28- 4.3 Main M a n age ment Menu The following inf ormation describes the ba sic functions of the main menu. Configuration System Switch information, system and IP related settings Ports Port link st.
-29- 4.4 Syste m Configuration De scri ption MAC Address The MAC a ddress fa ctory configured for the switch It can not be changed in any cases. S/W V ersion The firmware version currently running H/W.
-30- 4.4.1 M a n age ment VLAN M a nagement VLAN settings allow a dministrator to a ccess the switch a nd perform the switch ma nage- ment over a dedicated VLAN.
-31- 4.5 Ports Configuration Function Port The port number Link P o r t l i n k status Speed a nd duplex status with gr een ba ckground - port is link on Down with r ed backgr ound - port is link down.
-32- 4.6 VLANs VLAN Configuration Description VLAN Disable Select to disable VLAN function All ports are allowed to communicate with each others freely with no VLAN limitation.
-33- 4.6.1 Port-ba sed VLAN Mode Configuration Description Group 1, 2 Port-based VLAN group number Member ports Select member ports for the group [Apply] Click to apply the configuration change [Refresh] Click to refresh current configuration [Back] Click to go back to upper menu Operation in this mode: 1.
-34- 4.6.2 Port-ba sed VLAN ISP Mode Configuration Description Joint port Select a port as the joint port for all 5 port-based VLAN groups [Apply] Click to apply the configuration change [Refresh] Cli.
-35- 4.6.3 Adva nced VLAN Mode Configuration Description Ingress Default T ag Click to configure per port Ingress Default T ag settings Ingress Settings Click to configure per port ingress settings Eg.
-36- 4.6.3.1 Ingre ss Default T ag Configuration Description Port Port number PVID Port VID, VID f or Ingress Default T ag 1 ~ 4095 - decimal 12-bit VID value CFI CFI for Ingre ss Default T ag 0, 1 - .
-37- 4.6.3.2 Ingre ss Settings Configuration Description Port Port number T ag A ware Check tag data for every received packet T ag-awar e - set to activate T ag-ba sed mode T ag-ignor e - set to use .
-38- 4.6.3.3 Egre ss Settings Configuration Description Port Port number Insert T a g Activate tagging (Insert a tag to the packet) Enable - set to activate tagging Disable - set to disable tagging fu.
-39- 4.6.3.4 VLAN Groups Configuration Description Group Group number V I D VID of the VLAN to which this group is associated 1 ~ 4095 - decimal 12-bit VID value Member Ports Select the admitted egres.
-40- 4.6.4 Importa nt Note s for VLAN Configuration Some considerations should be checked in configuring VLAN settings: 1 . Switch VLAN Mode selection It is suggested to evaluate your VLAN application first and plan your VLAN configuration carefully before a pplying it.
-41- 4.7 Quality of Service QoS Configuration D e scri ption Port Port number 802.1p 802.1p priority cla ssification Enable - set to ena ble this cla ssification to the port f or priority-tagged a n d VLAN-tagged pa ckets Disa ble - 802.
-42- 4.7.1 802.1p M a pping Configuration Description Port n Port number n tag m 3-bit User priority tag value m ( ra nge : 0 ~ 7 ) Priority cla ss M a pped priority cla ss f or tag m on Port n Class .
-43- 4.7.2 DSCP Ma pping Configuration Description DSCP [0-63] Seven user-defined DSCP value s which are configured with a priority cla ss 0 ~ 63 - 6-bit DSCP value in decimal Priority The priority cl.
-44- 4.7.3 QoS Service Policy Configuration Description Port Port number Policy Service policy for egre ss priority a mong four egress cla ss queues Strict priority - high class queue is served first .
-45- 4.8 Port Mirroring Configuration Description Sniffer Port The port is forwarded all pa ckets received on the mirrored ports Mirrored Ports Select the ports which will be mirrored all received packets to the sniffer port.
-46- 4.9 802.1X Configuration Configuration De scri ption Mode Disa bled - disa ble 802.1x function Enabled - ena ble 802.1x function RADIUS IP IP a ddress of the Ra dius server RADIUS UDP Port The UD.
-47- [Re-authenticate] Click to perform a ma nual authentication for the port [Force Re initi alize] Click to perform a n 802.1x initi alization for the port [Re-authenticate All] Click to perform ma nual authentication for all ports [Force Re initi alize All] Click to perform 802.
-48- 4.10 Statistics Configuration De scri ption Port Port number Tx Bytes T otal of bytes tra nsmitted on the port Tx Frame s T otal of pa cket fra mes tra nsmitted on the port Rx Bytes T otal of byt.
-49- 4.1 1 Reboot System This menu is used to reboot the switch unit remotely with current configuration. Starting this menu will make your current http connection lost. Y ou must rebuild the connection to perf orm a ny ma nagement operation to the unit.
-50- 4.13.2 Upload Configuration File Enter the path a nd file na me of a configuration file for uploa ding. Configuration De scri ption Filena me Path a nd filena me (configuration) [Browse] Click to.
-51- Appendix. Fa ctory Def ault Settings System Configuration M a nagement VLAN - VID 0 M a nagement VLAN - CFI 0 M a nagement VLAN - User priority 0 IP Address 192.
-52- VLAN Group 1 - VID 1 VLAN Group 1 - Member Ports Port 1, 2, 3, 4, 5, 6 VLAN Group 1 - Source Port Check Disable VLAN Group 2 - VID 2 VLAN Group 2 - Member Ports None VLAN Group 2 - Source Port Ch.
-53- Port 1~Port 6 - tag 5 Cla ss 2 Port 1~Port 6 - tag 6 Class 3 Port 1~Port 6 - tag 7 Class 3 QoS DSCP Mapping DSCP 1 / Priority 0, Cla ss 0 DSCP 2 / Priority 0, Class 0 DSCP 3 / Priority 0, Class 0.
デバイスKTI Networks KGD-600の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
KTI Networks KGD-600をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはKTI Networks KGD-600の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。KTI Networks KGD-600の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。KTI Networks KGD-600で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
KTI Networks KGD-600を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はKTI Networks KGD-600の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、KTI Networks KGD-600に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちKTI Networks KGD-600デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。