LantronixメーカーLX6の使用説明書/サービス説明書
ページ先へ移動 of 74
Part Number 900-688-R Revision A December 2013 XPort Pro Lx6 Embedded Device Server User Guide.
XPort® Pro Lx6 Embedded Device Server User Gu ide 2 Intellectual Property © 2013 Lantronix, Inc. All rights re served. No pa rt of the co ntents of this book may b e transmitted or reproduced in an y form or by any means without the written permissio n of Lantronix.
XPort® Pro Lx6 Embedded Device Server User Gu ide 3 T able of Contents Intellectual Proper ty ___________ _____________ ___________ _____________ ________ 2 Warranty _______ _____________ ___________.
XPort® Pro Lx6 Embedded Device Server User Gu ide 4 To View Network 1 Interface Sta tus ____________ _____________ _____________ __ 25 Network (Ethernet Network “eth0 ”) Link Settings ___________.
XPort® Pro Lx6 Embedded Device Server User Gu ide 5 HTTP Settings _____________________ ___________ _____________ _____________ __ 45 To Configure HTTP Settings ______________________ _____________ _.
XPort® Pro Lx6 Embedded Device Server User Gu ide 6 11: Advanced Settings 59 Email Settings ________________ _____________ ___________ _____________ _______ 59 To View, Configure a nd Send Email ____.
XPort® Pro Lx6 Embedded Device Server User Gu ide 7 List of Figures Figure 2-1 XPort Pro Lx6 Prod uct Label ___________________ _____________ _____________ __ 15 Figure 4-1 Device Status Page _______.
XPort® Pro Lx6 Embedded Device Server User Gu ide 8 List of T ables Table 4-3 Web Manager Page s ____________________ __________ _____________ __________ 21 Table 5-1 Netwo rk Interface Settings ____.
XPort® Pro Lx6 Embedded Device Server User Gu ide 9 Table 10-15 Tunnel Default Se ttings ________ _____________ _____________ _____________ __ 58 Table 10-16 Discove ry Settings ____________________ .
XPort® Pro Lx6 Embedded Device Server User Gu ide 10 1: Using This Guide Purpose and Audience This guide provides the information nee ded to co nfigur e, use, and upda te the Lantr onix® XPort® Pro Lx6 embedded device server and application se rver.
1: Using This Guide XPort® Pro Lx6 Embedded Device Server User Gu ide 11 Additional Document ation Visit the Lantronix Web site at www.lantronix.com/su pport/documentation for the latest documentation and the following additional docum entation.
XPort® Pro Lx6 Embedded Device Server User Gu ide 12 2: Introduction The XPort Pro Lx6 embedded Ethernet devic e server is a comp lete network- enabling solut ion in a 30 (1.
2: Introduction XPort® Pro Lx6 Embedded Device Server User Gu ide 13 Patient Monitoring Devices Glucose Analyzers Infusion Pumps Protocol Support The XPort Pro Lx6 embedde d device se rver contain s a full-feat ured IP stack.
2: Introduction XPort® Pro Lx6 Embedded Device Server User Gu ide 14 XML: The XPort Pro Lx6 supports XML-based configura tion and setup records that make device configuration transp arent to users and administrators. XML is easily editable with a standard text or XML editor.
2: Introduction XPort® Pro Lx6 Embedded Device Server User Gu ide 15 Figure 2-1 XPort Pro Lx6 Produc t Label.
XPort® Pro Lx6 Embedded Device Server User Gu ide 16 3: Using DeviceInstaller This chapter covers the steps for locating a XPort Pro Lx6 unit an d viewing its properties and device details. DeviceIn staller application is a free utility pr ogram provided by Lantronix that discovers, configur es, upgrades and manages Lan tronix device server s.
3: Using DeviceInstaller XPort® Pro Lx6 Embedded Device Server User Gu ide 17 Group Configurable field. Enter a group to categorize th e XPort Pro Lx6. Double- click the field, type in the value, and press Enter to complete. This group name is local to this PC and is n ot visible on other PCs or laptops using DeviceInstaller.
XPort® Pro Lx6 Embedded Device Server User Gu ide 18 4: Configuration Using W eb Manager This chapter descr ibes how to configu re the XPort Pro Lx6 embe dded device serve r using Web Manager, the Lantro nix browser-based configuration t ool. The unit’s configuration is sto red in non- volatile memory and is retained with out power.
4: Configuration Using Web Manager XPort® Pro Lx6 Embedded Device Server User Gu ide 19 Device S t atus Page The Device Status page is the first to ap pear a fter you log into Web Manager . The Device Sta tus page also appear s when you click Status in the me nu bar in W eb Manage r.
4: Configuration Using Web Manager XPort® Pro Lx6 Embedded Device Server User Gu ide 20 We b Manager Component s The layout of a typical We b Manager page is below.
4: Configuration Using Web Manager XPort® Pro Lx6 Embedded Device Server User Gu ide 21 Web Manager pages have these sections: The menu bar always appears at the left side of the page, re gardless of the page shown. The menu bar lists the names of the pages availab le in the Web Manager.
4: Configuration Using Web Manager XPort® Pro Lx6 Embedded Device Server User Gu ide 22 Email Shows emai l statisti cs and lets you clear th e email l og, configu re email settings, and send an email.
XPort® Pro Lx6 Embedded Device Server User Gu ide 23 5: Network Settings The Network Settings show the status of the Et hernet interface/lin k and let yo u configure the settings on the device. Interface settings are rela ted to t he conf iguration of the IP and related protocols .
5: Network Settings XPort® Pro Lx6 Embedded Device Server User Gu ide 24 To Configure Network 1 Interface Settings Using Web Manager To modify Ethernet (eth0) settings, click Network on the menu and select Network 1 -> Interface -> Configuration .
5: Network Settings XPort® Pro Lx6 Embedded Device Server User Gu ide 25 Using the CLI To enter the eth0 command level: enable -> config -> if 1 Using XML Include in your file: <conf.
5: Network Settings XPort® Pro Lx6 Embedded Device Server User Gu ide 26 To Configure Networ k 1 Link Settings Using Web Manager To modify Ethernet (eth0) Link information, click Ne twork on the menu and se lect Network 1 > Link > Configuration .
XPort® Pro Lx6 Embedded Device Server User Gu ide 27 6: Line and T unnel Settings The XPort Pro Lx6 embedded d evice server cont ains one line using a standard RS232/RS485 serial port.
6: Line and Tunn el Settings XPort® Pro Lx6 Embedded Device Server User Gu ide 28 Table 6-2 Line Command Mode Settings To Configure Line Settings The following section describes the steps to view and configure Line 1 settings; these steps apply to other line instan ces of the device.
6: Line and Tunn el Settings XPort® Pro Lx6 Embedded Device Server User Gu ide 29 To configure a specific line in Command Mode, click Line in the menu and select Line 1 -> Command Mode ( Table 6-2 ).
6: Line and Tunn el Settings XPort® Pro Lx6 Embedded Device Server User Gu ide 30 Table 6-3 Tunnel Seria l Settings To Configure Tunnel Serial Settings Using Web Manager To configure the Serial Settings for a specific tunnel, click Tunnel in the menu and se lect Tunnel 1 -> Serial Settings .
6: Line and Tunn el Settings XPort® Pro Lx6 Embedded Device Server User Gu ide 31 To Configure Tunnel Pa cking Mode Settings Using Web Manager To configure the Packing Mode for a sp ecific tunnel, click Tunnel in the menu and select Tunnel 1 -> Packing Mode .
6: Line and Tunn el Settings XPort® Pro Lx6 Embedded Device Server User Gu ide 32 Table 6-5 Tunnel Accept Mod e Settings Tunnel Acce pt Mode Settings Description Mode Set the method used to start a tunnel in Accept mode. Choices are: Disable = do not accept an incoming connection .
6: Line and Tunn el Settings XPort® Pro Lx6 Embedded Device Server User Gu ide 33 To Configure Tunnel Ac cept Mode Settings Using Web Manager To configure the Accept Mode for a specific tunnel, click Tunnel in the menu and select Tunnel 1 -> Accept Mode .
6: Line and Tunn el Settings XPort® Pro Lx6 Embedded Device Server User Gu ide 34 For Connect Mode using UDP, the XPort Pro Lx6 accepts packets from any device on the network. It will send packets to the last device that sent it packets. Note: The Port in Connect Mode is not the same port configured in Accept Mode.
6: Line and Tunn el Settings XPort® Pro Lx6 Embedded Device Server User Gu ide 35 To Configure Tunnel Co nnect Mode Settings Using Web Manager To configure the Connect Mode for a specific tunnel, click Tunn el in the menu and select Tunnel 1 -> Connect Mode .
6: Line and Tunn el Settings XPort® Pro Lx6 Embedded Device Server User Gu ide 36 To Configure Tunnel Disc onnect Mode Settings Using Web Manager To configure the Disconnect Mode for a specific tunnel, click Tunnel in the menu an d select Tunnel 1 -> Disconnect Mode .
6: Line and Tunn el Settings XPort® Pro Lx6 Embedded Device Server User Gu ide 37 To Configure Tunnel Mode m Emulation Settings Using Web Manager To configure the Modem Emulatio n fo r a specific tunnel, click Tunnel in the menu and select Tunnel 1 -> Modem Emulation .
XPort® Pro Lx6 Embedded Device Server User Gu ide 38 7: T erminal and Host Settings Predefined conne ctions are available via Telnet or a serial port. A user can choose one of th e presented options and the device au tomati cally makes the predefined conne ction.
7: Terminal and Host Settings XPort® Pro Lx6 Embedded Device Server User Gu ide 39 To Configure the Termin al Network Connection Using Web Manager To configure the Terminal on Networ k, click Terminal on the men u and select Network -> Configuration .
XPort® Pro Lx6 Embedded Device Server User Gu ide 40 8: Configurable Pin Manager The Configurable Pin Manager is responsible for as signmen t and control of the configurable pins (CPs) available on the XPort Pro Lx6 embedded de vi ce service. There are thre e configurable pin s on the XPort Pr o Lx6.
8: Configurable Pin M anager XPort® Pro Lx6 Embedded Device Server User Gu ide 41 Notes: To modify a CP, all groups in which it is a member must be disabled . The changes to a CP configuration ar e no t saved in FLASH. Inst ead, these CP settings are used when the CP is added to a CP Group.
8: Configurable Pin M anager XPort® Pro Lx6 Embedded Device Server User Gu ide 42 To Configure CPM Settings Using Web Manager To configure a configurable pin, click CPM in the menu, select CPs and then the desired CP to configure. To configure a CPM Group, click CPM in the menu, select Groups and then the desired Group Name to configure.
XPort® Pro Lx6 Embedded Device Server User Gu ide 43 9: Services Settings DNS Settings This section describes the active run- time sett ings for the domain name system (DN S) protoc ol. The primary and secondary DNS addresses come from th e active interface.
9: Services Settings XPort® Pro Lx6 Embedded Device Server User Gu ide 44 FTP Settings The FTP protocol can be used to upload and download use r files, and upgrade the XPort Pro Lx6 firmware. A configurable option is provided to enable or disable acce ss via this pr otocol.
9: Services Settings XPort® Pro Lx6 Embedded Device Server User Gu ide 45 To View or Confi gure Syslog Settings Using Web Manager To configure the Syslog, click Syslog in the menu.
9: Services Settings XPort® Pro Lx6 Embedded Device Server User Gu ide 46 To Configure HTTP Settings Using Web Manager To configure HTTP settings, click HTTP in the menu and select Configuration . To view HTTP statistic s, click HTTP in the menu and select Statis tics .
9: Services Settings XPort® Pro Lx6 Embedded Device Server User Gu ide 47 Using the CLI To enter the HTTP command level: ena ble -> config -> http Using XML Include in your file: <co.
XPort® Pro Lx6 Embedded Device Server User Gu ide 48 10: Maintenance and Diagnostics Settings Filesystem Settings Use the file system to list, view, create, upload, co py, move, remove, and tran sfer files. The XPor t Pro Lx6 embedded device server uses a flash file system to stor e files.
10: Maintenance and Diagnostics Settin gs XPort® Pro Lx6 Embedded Device Server User Gu ide 49 File Modification The XPort Pro Lx6 allows for the creation and remova l of files on its filesystem. Table 10-2 File Modification Sett ings File Transfer Files can be transferred to and from the XPort Pro Lx6 via the TFTP pro tocol.
10: Maintenance and Diagnostics Settin gs XPort® Pro Lx6 Embedded Device Server User Gu ide 50 To Transfer or Modi fy Filesystem Files Using Web Manager To create a new file or directory, upload an existing file, copy or move a file, click Filesystem in the menu and se lect Browse .
10: Maintenance and Diagnostics Settin gs XPort® Pro Lx6 Embedded Device Server User Gu ide 51 ICMP and ICMPv6 Settings Table 10-5 ICMP Network Stack Settin gs To Configure ICMP Ne twork Stack Settings Using Web Manager To configure ICMP p rotocol settings, click Protocol Stack in the menu a nd select ICMP .
10: Maintenance and Diagnostics Settin gs XPort® Pro Lx6 Embedded Device Server User Gu ide 52 To Configure ARP Network Stack Settings Using Web Manager To configure ARP protocol setting s, click Pr otocol Stack in the me nu and select ARP .
10: Maintenance and Diagnostics Settin gs XPort® Pro Lx6 Embedded Device Server User Gu ide 53 Diagnostics The XPort Pro Lx6 has several tools for diag nostic s and statistics . Variou s options allow for the configuration or viewing of IP socket inform ation, ping, traceroute, memory, and processes.
10: Maintenance and Diagnostics Settin gs XPort® Pro Lx6 Embedded Device Server User Gu ide 54 Ping The ping command can be used to test connectivity to a remote host. Table 10-8 Ping Sett ings To Ping a Remote Host Using Web Manager To ping a Remote Host, click Diagnost ics in the menu and select Ping .
10: Maintenance and Diagnostics Settin gs XPort® Pro Lx6 Embedded Device Server User Gu ide 55 Using the CLI To enter the command leve l: enable Using XML Not applicable.
10: Maintenance and Diagnostics Settin gs XPort® Pro Lx6 Embedded Device Server User Gu ide 56 Using the CLI To enter the command leve l: enable -> device, show memory Using XML Include in.
10: Maintenance and Diagnostics Settin gs XPort® Pro Lx6 Embedded Device Server User Gu ide 57 System Settings The XPort Pro Lx6 System settings allow for r ebooting the device, restoring factory de faults, uploading new firmware and up dating a system’s short and long name.
10: Maintenance and Diagnostics Settin gs XPort® Pro Lx6 Embedded Device Server User Gu ide 58 Table 10-13 Line Configurat ion Default Sett ings Table 10-14 Network Configuration Default Settings Tab.
XPort® Pro Lx6 Embedded Device Server User Gu ide 59 1 1: Advanced Settings Email Settings View and configure email alerts relati ng to events occu rring within the system.
11: Advanced Settings XPort® Pro Lx6 Embedded Device Server User Gu ide 60 Using XML Include in your file: <configgroup name=”email” instance=”1”> Command Line Interface Settings Th.
11: Advanced Settings XPort® Pro Lx6 Embedded Device Server User Gu ide 61 Telnet Settings The Telnet s ettings cont rol CLI acces s to the XPor t Pro Lx6 over the T elnet protoco l. Table 11-3 Telnet Settings To Configure Telnet Settings Using Web Manager To configure Telnet settings, click CLI in the menu and select Config uration .
11: Advanced Settings XPort® Pro Lx6 Embedded Device Server User Gu ide 62 Table 11-4 XML Exporting Configuration To Export Configuration in XML Format Using Web Manager To export configuration for mat, click XML in the menu and select Export Configuration .
11: Advanced Settings XPort® Pro Lx6 Embedded Device Server User Gu ide 63 To Export in XML Format Using Web Manager To export configuration for mat, click XML in the menu and select Export Status . Using the CLI To enter the XML command level: enable -> xml Using XML Not applicable.
11: Advanced Settings XPort® Pro Lx6 Embedded Device Server User Gu ide 64 To Import Configuration in XML Format Using Web Manager To import configuration , click XML in the menu and select Impo rt Configuration . Using the CLI To enter the XML command level: enable -> xml Using XML Not applicable.
XPort® Pro Lx6 Embedded Device Server User Gu ide 65 12: Updating Firmware Obt aining Firmware Obtain the most up-to-date firmware and release notes for the unit from the Lantr onix Web site ( www.lantronix.com/ supp ort/downloads/ ) or by using anonym ous FTP ( ftp://ftp.
12: Updating Firmware XPort® Pro Lx6 Embedded Device Server User Gu ide 66 3. Select the file and click Open . The selecte d file name appears on. 4. Click Upload to install the firmware on the XPort Pro Lx6 embedded device server. 5. Click OK in the confirmation popup which appears.
XPort® Pro Lx6 Embedded Device Server User Gu ide 67 13: Branding the XPort Pro Lx6 This chapter describes how to brand your XPort Pro Lx6 embedded de vice server by using Web Manager and Command Lin e Interface (CLI).
13: Branding the XPort Pro Lx6 XPort® Pro Lx6 Embedded Device Server User Gu ide 68 Short and Long Name Customization You can customize the short and long names in you r XPort Pro Lx6 device. The names disp lay in the CLI show co mmand and in the System web page i n the Current Configuration ta ble.
XPort® Pro Lx6 Embedded Device Server User Gu ide 69 Appendix A: T echnical Support If you are unable to r esolve an iss ue using the informatio n in this doc umentation , please t he contact Tech nical Support. North America Hours: 6:00am - 5:00pm Pacific Time Mon.
Appendix A:Technical Support XPort® Pro Lx6 Embedded Device Server User Gu ide 70 Online Support options listed below are available 2 4 hour s a day, 7 days a week at the Lantro nix support page at http://www.
XPort® Pro Lx6 Embedded Device Server User Gu ide 71 Appendix B: Compliance (According to ISO/IEC Guide 17050-1, 170 50-2 and EN 45014) Manufacturer's Name & Address: Lantronix, Inc.
Appendix B: Compliance XPort® Pro Lx6 Embedded Device Server User Gu ide 72 RoHS Notice All Lantronix products in the following famili es are Chin a RoHS-compliant a nd free of the foll owing hazardo.
XPort® Pro Lx6 Embedded Device Server User Gu ide 73 Appendix C: Binary to Hexadecimal Conversions Many of the unit's co nfigurat ion proc edures require you to assemble a ser ies of options (represented as b its) into a comple te command (r epresented as a byte).
Appendix C: Binary to Hexa decimal Conversions XPort® Pro Lx6 Embedded Device Server User Gu ide 74 Figure C-2 Wind ows Scientifi c Calculator 4. Click Hex .
デバイスLantronix LX6の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Lantronix LX6をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはLantronix LX6の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Lantronix LX6の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Lantronix LX6で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Lantronix LX6を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はLantronix LX6の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Lantronix LX6に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちLantronix LX6デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。