Part Num ber 900 - 451 Revision C Februar y 2010 SDS1 101 /2101 User G uide.
SDS1101 /2 101 User G uide 2 Copyright & Tr ademark © 200 9 and 201 0 , Lantroni x. All rights r eserved. No p art of the con tents of this book may be tr ansmitted or r eproduced in any form or by any m eans without th e written perm ission of Lantron ix.
SDS1101/2 101 User G uide 3 Revisi ons Date Rev. Comments 8 /0 6 A Ini tial do cumen t 1/09 B Include SDS2 101 product ; updated to fir mware v 6.5.0.0 2/10 C Update doc ument with c orrecti ons.
SDS1101/2 101 User G uide 4 Contents 1: Using This Guide 9 Purpose an d Audience ________________________________________________ 9 Chapter S ummar y __________________________________________________.
Contents SDS1101/2 101 User G uide 5 Serial Por t Connectio n ____________________________________________ 39 Exiting Setup Mod e _________________________________________________ 39 6: Setup Mode: Se.
Contents SDS1101/2 101 User G uide 6 Disable T FTP Firm ware Update ____________________________________ 61 Disable Port 77FE (H ex) __________________________________________ 62 Disable W eb Server _.
Contents SDS1101/2 101 User G uide 7 A : A lternat ive Way s to A ssign an I P A ddr ess 87 DHCP _________________________________________________________ 87 AutoIP ___________________________________.
Contents SDS1101/2 101 User G uide 8 Table 7 - 4. Res erve d Port N umbers _______________________________________ 46 Table 7 -5 . Con nect Mode Optio ns ________________________________________ 47 Table 7 - 6. Manual Connec tion Addr ess Exam ple ____________________________ 49 Table 7 - 7.
SDS1101/2 101 User G uide 9 1 1 : : U U s s i i n n g g T T h h i i s s G G u u i i d d e e Purpose and Audience This guid e provides th e inform ation needed to c onfigure, use , and update the SDS1101 & SDS 2101 device server s . It is f or system adm inistrators an d those responsib le for instal ling and m aintaining th e SDS .
1: Using Th is Guide SDS1101/2 101 User G uide 10 15: SDS2101 T echnical Specificat ions Lists techn ical specifi cations f or the SDS 2 101. A: Alternati ve Ways to A ssign an IP Address Provides deta iled informatio n about using DHCP, AutoIP, BOOTP A RP, and Telnet to assign an I P addres s.
SDS1101/2 101 User G uide 11 2 2 : : I I n n t t r r o o d d u u c c t t i i o o n n The SDS1 101 is a single - port device ser ver and the SD S2101 is a dual port devi ce server th at provide a q uic.
2: Introduc tion SDS1101/2 101 User G uide 12 Figure 2-1 . Serial Tunn eling Example The Com Port Redirect o r software inc luded on th e product CD s implif ies the integrati on process b y extending t he functiona lity of COM - port - based W indows™ applicat ions.
2: Introduc tion SDS1101/2 101 User G uide 13 Protoc ol Support The SDS uses the Inter net Protoco l (IP) for ne twork com munications and the Transm ission Control Protocol (T CP) to ass ure that no data is lost or du plicated a nd that ever ything sent to t he connecti on arrives c orrectly at th e target.
2: Introduc tio n SDS1101/2 101 User G uide 14 Product Information Label The produc t inform ation label on th e undersi de of the unit c ontains th e following inform ation about y our sp ecific unit.
SDS1101/2 101 User G uide 15 3 3 : : G G e e t t t t i i n n g g S S t t a a r r t t e e d d This c hapter describes how to get y our SDS up an d running in the shortes t possib le tim e. Package Contents Verif y and inspect the c ontents of the SDS11 01 /2101 pac kage using the follo w in g list.
3: Getting Started SDS1101/2 101 User G uide 16 Insta lling the SDS Figure 3-1 . SDS1101 Conn ected to Seri al Device a nd Network To install the u nit : C omplete th e following s teps in order . Refer to th e num bers in the figure above . Note: See the sec tions that fol low for det ails about connectors and pinouts .
3: Getting Started SDS1101/2 101 User G uide 17 Requir ed Information Before conf iguring the SDS , ha ve the follo wing inform ation availa ble: Hard ware A ddr ess Take not e of the unit’s hardware ad dress (also k nown as the Ethernet or MAC address) .
3: Getting Started SDS1101/2 101 User G uide 18 Assigning the I P Address : D eviceInstaller This c hapter covers the s teps f or getting the SDS1101 /2101 device s erver onli ne and for view ing its current configurati on. Note: DeviceInst aller o nlin e H elp prov ides more detailed inform ation on using DeviceI nstaller.
3: Getting Started SDS1101/2 101 User G uide 19 7. Select th e device fr om the m ain window list a nd s elec t Ping f rom the T ools me nu. The Ping Device dialog box s hows the IP ad dress of the selected un it. 8. From the T ools m enu, click the Ping butto n.
3: Getting Started SDS1101/2 101 User G uide 20 Devi ce Fam ily No n- configurabl e field. Dis plays the SDS1101 ’s and SDS2101’s dev ice fam ily type as SDS . Type Non - configurabl e field. Dis plays the device type as SDS1101 or SDS2101 . ID Non - configurabl e field .
3: Getting Started SDS1101/2 101 User G uide 21 Supports Em ail Trigger s Non - c onfig urable field. Display s False . Supports AE S Data Stream Non - configurabl e field. Dis plays True . Supports 4 85 Non - configurabl e field. Dis plays True . T he SDS sup ports the RS - 485 protoc ol.
3: Getting Started SDS1101/2 101 User G uide 22 2. To enter Se tup Mode, c ycle the uni t's power (po wer off and bac k on). After power - up , the self - tes t begins and the red Diag nostic LED s tarts blink ing. You have on e second to enter thr ee lowercase x charac ters.
SDS1101/2 101 User G uide 23 4 4 : : C C o o n n f f i i g g u u r r a a t t i i o o n n U U s s i i n n g g W W e e b b - - M M a a n n a a g g e e r r You mus t configure the unit so it c an comm unicate on a net work with your serial device.
4: Configur ation Usin g Web - Mana ger SDS1101/2 101 User G uide 24 Figure 4-1 . Lantronix Web - Manager The m ain menu is in the left pan e of the W eb - Manager w indow for bo th the SDS1 101 and SDS2101 . Netw o rk Conf iguration The unit ’s network values displa y when you se lect Network from the main menu.
4: Configur ation Usin g Web - Mana ger SDS1101/2 101 User G uide 25 A ut omatic IP Address Configura tion A n IP addres s can be assig ned automatical ly. You the n enter related network setting s. To assign an IP address au tomatically: 1. On the m ain menu, cl ick Network .
4: Configur ation Usin g Web - Mana ger SDS1101/2 101 User G uide 26 4. W hen y ou are finished, click the OK button. 5. On the m ain menu, cl ick Apply Settings . Ethernet Configuration You mus t specify the s peed and direc tion of data t ransmiss ion.
4: Configur a tion Usin g Web - Mana ger SDS1101/2 101 User G uide 27 Figure 4-3 . Server Settings To configure the SDS ’ s device se rver sett ings: 1. On the m ain menu, cl ick Serve r . 2. Configure or modif y the f ollowing f ields: Server Confi guration Telnet Pas sword Enter the pa ssword re quired for T elnet acces s.
4: Configur ation Usin g Web - Mana ger SDS1101/2 101 User G uide 28 Monitor Mode @ Bootup Select Dis able to disable en try into the monitor mod e us ing the yyy or xx1 key sequence at start up.
4: Configur ation Usin g Web - Mana ger SDS1101/2 101 User G uide 29 Figure 4-4 . Hostlist Settings 2. Enter or m odify the fo l lowin g fields: Retry S ettings Retry C ounter Enter the v alue for t he number of times the SDS should attempt to retry conne cting to t he host list .
4: Configur ation Usin g Web - Mana ger SDS1101/2 101 User G uide 30 1. On the m ain menu, cl ick Seria l Settings (under Ch annel 1 ) to disp lay the Ser ial Settings win dow.
4: Configur ation Usin g Web - Mana ger SDS1101/2 101 User G uide 31 default set ting is 9600 . Data Bits Indicates th e number of bits in a transmitted data pack age. The defau lt setting i s 8 . Parity Checks for the parity bit. The default setti ng is None .
4: Configur ation Usin g Web - Mana ger SDS1101/2 101 User G uide 32 Flush Output Buffe r (Network to S erial) With Activ e Connect Select Y es to c lear the output buffer with a connecti on that is initiated from the dev ice to the networ k. The default setting i s No .
4: Configur ation Usin g Web - Mana ger SDS1101/2 101 User G uide 33 Figure 4-6 . TCP Connectio n Settings 2. In the a vailable fields , enter or modif y t he follow ing inform ation: Connect Protoc ol Protocol From the dr op - down menu, select TCP .
4: Configur ation Usin g Web - Mana ger SDS1101/2 101 User G uide 34 Modem Esca pe Sequence Pass Throu gh Disable or enable the unit's abi lity to send the escap e sequence. T he default i s Y (Yes) (s end the es cape sequence). Connect Mod e: Active Connection Activ e Connect Select None ( default) to dis able Activ e Connect .
4: Configur ation Usin g Web - Mana ger SDS1101/2 101 User G uide 35 Use the ter minal name for the T elnet terminal ty pe. Enter only one name. W hen this option is enabled, the unit also r eacts to the end of record (EOR ) and binary options, w hich can be used for a pplications such as t erminal emulati on to IBM hosts.
4: Configur ation Usin g Web - Mana ger SDS1101/2 101 User G uide 36 Figure 4-7 . UDP Conne ction Settings Connect Protoc ol Protocol Select UD P from the drop - down me nu. Datagra m Mode Datagram T ype Configures the remote IP or netw ork broadca st address and the remote port.
4: Configur ation Usin g Web - Mana ger SDS1101/2 101 User G uide 37 Remote Port Enter the por t number of the remot e device. Remote Host Enter the IP address of the r emote dev ice. Use Broadca st Selec t to broadcast t he UDP datagra m. Datagra ms of type 01 can be sent as a broadc ast by enabl ing this opt ion.
SDS1101/2 101 User G uide 38 5 5 : : C C o o n n f f i i g g u u r r a a t t i i o o n n v v i i a a T T e e l l n n e e t t o o r r S S e e r r i i a a l l P P o o r r t t ( ( S S e e t t u u p p M M o o d d e e ) ) You mus t configure the unit so it c an comm unicate on a net work with your serial device.
5: Configur ation via Te lnet or Seri al Port (Set up Mode) SDS1101/2 101 User G uide 39 Figure 5-1 . M AC Addr es s 3. To enter Se tup Mode, press Enter within 5 s econds. The c onfiguration s ettings displa y , f ollowed b y the Ch ang e Setup m enu.
5: Configur ation via Te lnet or Seri al Port (Set up Mode) SDS1101/2 101 User G uide 40 To save all ch anges and r eboot the de vice, select option 9 Save and exit f rom the Chan ge Setup m enu. All values are stored in nonvolatile m emor y . To exit the co nfiguration mode without s aving an y changes or re booting.
SDS1101/2 101 User G uide 41 6 6 : : S S e e t t u u p p M M o o d d e e : : S S e e r r v v e e r r C C o o n n f f i i g g u u r r a a t t i i o o n n This c hapter explains how to conf igure the net work settings . Note: Current va lues display in parentheses .
6: Setup Mode: Ser ver C onfigura tion SDS1101/2 101 User G uide 42 default se tting is N (No) , meaning the gate w a y addr ess has not been set. T o set the gatewa y ad dress, type Y a nd enter the a ddress.
6: Setup Mode: Ser ver Configura tion SDS1101/2 101 User G uide 43 There ar e three m ethods for ass igning DHCP nam es to the un it. Default DHCP Name : If y o u do not chang e the DHCP name, and you are using an I P of 0.0.0.0, t hen the DHC P name def aults to XX .
SDS1101/2 101 User G uide 44 7 7 : : S S e e t t u u p p M M o o d d e e : : C C h h a a n n n n e e l l C C o o n n f f i i g g u u r r a a t t i i o o n n This c hapter explains how to conf igure the ser ial port. Notes: Current values displa y in p arenthesis.
7: Setup Mode: C hannel Configurat ion SDS1101/2 101 User G uide 45 I/F ( Interface) M ode The Interf ace (I/F) Mod e is a bit - coded byte entered in hexadec imal notatio n.
7: Setup Mode: C hannel Configurat ion SDS1101/2 101 User G uide 46 Use the fol lowing tabl e to select f low control o ptions: Table 7-3 . Flo w Control Opti ons Flow Control Option Hex No flow contr.
7: Setup Mode: C hannel Configurat ion SDS1101/2 101 User G uide 47 Ta ble 7-5 . Connect Mode Options Connect Mode Option 7 6 5 4 3 2 1 0 a) Incoming C onnecti on Never accept inc oming 0 0 0 Accept w.
7: Setup Mode: C hannel Configurat ion SDS1101/2 101 User G uide 48 already esta blished. D efault s etting. b) Response Character R esponse A single char acter i s transmitt ed to the seri al port w hen there is a change in c onnection state: C = connec ted, D = dis connected, N = host unr eachable.
7: Setup Mode: C hannel Configurat ion SDS1101/2 101 User G uide 49 Table 7-6 . Manu al Connectio n Addr ess Example Command String Result if r emote IP is 129.1.2.3 an d remote po rt is 1234 C121.2.4. 5/1 Complete ov erride; co nnection is started w ith host 121.
7: Setup Mode: C hannel Configurat ion SDS1101/2 101 User G uide 50 F igure 7-2 . Hostlist Option.
7: Setup Mode: C hannel Configurat ion SDS1101/2 101 User G uide 51 To enable the hos tlist: 1. Enter a Connect Mode of 0x20 ( 2 X ), where X is a ny digit. T he menu sho w s you a list of current entries already def ined in the pr oduct. 2. To delete , modif y , or a dd an entry, se lect Yes .
7: Setup Mode: C hannel Configurat ion SDS1101/2 101 User G uide 52 transferred. Quiet M ode (without echo) re fers to the modem not sending an a nswer to t he commands re ceived (or d isplayin g what was ty ped).
7: Setup Mode: C hannel Configurat ion SDS1101/2 101 User G uide 53 W hen an active connec tion is in ef fect, the un it transfer s data and does not proces s comm ands received f rom the seria l interfac e. W hen a connection is ter minated or l ost, the unit r everts to comm a nd mode.
7: Setup Mode: C hannel Configurat ion SDS1101/2 101 User G uide 54 Note: The unit rec ognizes thes e AT commands as single c ommands s uch as ATE0 or AT V1; it does not recogn ize compound c ommands suc h as ATE 0V .
7: Setup Mode: C hannel Configurat ion SDS1101/2 101 User G uide 55 DisConnMode (00) ? _ Notes: In DisConnMod e (Discon nect Mode), DT R drop eith er drops the connection or is ignored .
7: Setup Mode: C hannel Configurat ion SDS1101/2 101 User G uide 56 Table 7- 10 . Flush Mode Opti ons Function 7 6 5 4 3 2 1 0 Input Buffer (Seria l to Netw ork) Clear w ith a connection initiate d fr.
7: Setup Mode: C hannel Configurat ion SDS1101/2 101 User G uide 57 Option 7 6 5 4 3 2 1 0 2- Byte Send Ch aracter Se quence 1 Send Immedia tely After Send char s 1 Packing Interv al Pack ing Interval def ines how lo ng the unit shou ld wait before sending accum ulated character s.
7: Setup Mode: C hannel Configurat ion SDS1101/2 101 User G uide 58 disables th e recognit ion of the c haracters. Alt ernativel y, the unit can interpret two character s as a sequenc e (see Pack C ontrol ).
SDS1101/2 101 User G uide 59 8 8 : : S S e e t t u u p p M M o o d d e e : : A A d d v v a a n n c c e e d d S S e e t t t t i i n n g g s s Expert Se ttings (Opti on 5) Note: You can cha nge these set tings using T elnet or s erial connectio ns, but not all of t hem are av ailable on the W eb - Manager .
8: Setup Mode: Adv anced Settings SDS1101/2 101 User G uide 60 sequences ( only durin g the bootup s equence) . The default f or Disa ble Monitor Mode at bootu p is N (No). (See 10: Monitor Mode .) Monitor Mode @ bootup : enabled HT TP Port Number This optio n allows the configurati on of the web server por t number.
8: Setup Mode: Adv anced Settings SDS1101/2 101 User G uide 61 Figure 8-2 . Security Settings Disable SNMP (N) ? SNMP Community Name (public): Disable Telnet Setup (N) ? Disable TFTP Firmware Update (.
8: Setup Mode: Adv anced Settings SDS1101/2 101 User G uide 62 Disable Port 77F E (Hex) Note: If y ou choose t o disable this option, keep in min d that disabl ing both Telnet Set up and Port 7 7FE will prevent users from ac cessing the setup menu from the networ k.
8: Setup Mode: Adv anced Settings SDS1101/2 101 User G uide 63 configurat ion informat ion includi ng the encr yption key are sent in clear text over the network. To confi gure A E S e ncryption on the SDS : Figure 8-3 . Encry ption Ke y s 1. W hen prompted to enab le encryptio n, press Y .
8: Setup Mode: Adv anced Settings SDS1101/2 101 User G uide 64 Defaul t Settings (Option 7) Select 7 to res et the unit’s Channe l 1 c onfigurat ion and expert settings to t he default settings . The server conf iguration s ettings f or IP address, gate way IP ad dress, and netmask remain unchan ged.
8: Setup Mode: Adv anced Settings SDS1101/2 101 User G uide 65 (1- 65535) MTU Size (512 – 1400) 0 (resulti ng in an ope rational v alue of 1400) Enable alt ernate M AC No ( for OEM use only) Etherne.
SDS1101/2 101 User G uide 66 9 9 : : F F i i r r m m w w a a r r e e U U p p g g r r a a d d e e s s Obtai ning Firmware You can o btain the m ost up - to - date f irmware a nd releas e notes for the unit from the Lantronix web site ( www.lantr onix.com ) or by using an ony m ou s FTP ( ftp.
9: Firmwar e Upgrades SDS1101/2 101 User G uide 67 Figure 9-1 . TFTP Window After the f irmware has been loaded a nd stored ( approxim ately 8 seconds to complete ) t he unit perf orms a power r eset.
9: Firmwar e Upgrades SDS1101/2 101 User G uide 68 2. From the T ools m enu, select A dv anced/Recov er Firmw are . The Serial Port Firm ware Upgra de window displa y s. 3. For Port on PC , e nter the COM port on t he PC that is connected to the serial port of the Lantronix un it.
SDS1101/2 101 User G uide 69 1 1 0 0 : : M M o o n n i i t t o o r r M M o o d d e e Monitor M ode is a com mand - line interface use d for diagnostic purposes. There ar e two wa y s to ente r Monitor Mode : locally usin g the serial p ort or rem otely using the networ k.
10: Monitor Mode SDS1101/2 101 User G uide 70 Table 10 -1 . Monit or Mod e Com mands Command Command Name Function VS x .x.x .x Version Queries softw are header re cord (16 byte s) of unit w ith IP ad dr es s x. x. x.x. GC x.x. x. x Get Config uration Gets confi guration of u nit with IP address x .
SDS1101/2 101 User G uide 71 1 1 1 1 : : T T r r o o u u b b l l e e s s h h o o o o t t i i n n g g a a n n d d C C o o n n t t a a c c t t I I n n f f o o r r m m a a t t i i o o n n This c hapter discus ses how you can diagnose a nd fix errors quickly without having to contact a dealer or Lan tronix.
11: Troubl eshooting a nd Contact Inf ormation SDS1101/2 101 User G uide 72 SDS2101 LEDs The f ollowing LEDs ar e on the top of the S DS2 101: Power / Diagn ostic (Blu e) RX Seria l 1 Act ivit.
11: Troubl eshooting a nd Contact Inf ormation SDS1101/2 101 User G uide 73 Problem /Message Reason Solution When you attempt to assign a n IP address to t he unit by t he ARP method, t he "Press Ent er to go into Setup M ode " error "(des cribed below) me ssage display s.
11: Troubl eshooting a nd Contact Inf ormation SDS1101/2 101 User G uide 74 Problem /Message Reason Solution W hen yo u try to ent er the setu p mode on the d evice serv er using the seria l port, you g et no response. The issue i s most likely something cov ered in the previous pr oblem, or possibly , you have Caps Lock on.
11: Troubl eshooting a nd Contact Inf ormati on SDS1101/2 101 User G uide 75 Technical S upport Europe, Middle Ea st, and Africa Phone: +3 3 (0) 1 39 30 4 1 72 Em ail: eu_techs upp@lantr onix.com or eu_support @lantronix.com Firm ware downloads, F AQs, and the m ost up - to - da te docum entation are av ailable at: www.
SDS1101/2 101 User G uide 76 1 1 2 2 : : S S D D S S 1 1 1 1 0 0 1 1 C C o o n n n n e e c c t t i i o o n n s s a a n n d d P P i i n n o o u u t t s s Serial Port The SDS 1101 has a f emale DCE DB25 s erial port t hat supports R S - 232 a nd RS - 485/422 ser ial standar ds (software se lectable) up to 230 Kbau d.
12: SDS110 1 Connec tions and Pinou ts SDS1101/2 101 User G uide 77 Figure 12 -3 . DB25 Femal e Inter face RS422 (4 wi re mo de) Figure 12 -4 . DB25 Fem ale Inter face RS485 (2 wire mode ) M odem Cable W hen attaching the DB2 5 of the SD S 1101 to th e DB9 com port on a PC, us e a standar d straight - t hrough ser ial cable.
12: SDS110 1 Connec tions and Pinou ts SDS1101/2 101 User G uide 78 Figure 12 -5. Modem Cable Ne tw o rk Port The unit's back panel c ontains a power plug and an RJ45 (10/ 100) Ethernet port.
12: SDS110 1 Connec tions and Pinou ts SDS1101/2 101 User G uide 79 Ethernet Connector Pinouts The SDS1 101 supp orts 10/ 100 Mbps half or f ull duplex Eth ernet throu gh an RJ45 connector. Figure 12 -7. RJ45 Ethern et Connecto r Pow er Plug Power input on the power plug is 9 - 30 VDC (center +) or 10 - 24 V AC (1.
SDS1101/2 101 User G uide 80 1 1 3 3 : : S S D D S S 2 2 1 1 0 0 1 1 C C o o n n n n e e c c t t i i o o n n s s a a n n d d P P i i n n o o u u t t s s SDS2101 S erial Po rts The SDS2 101 has two m a.
13: SDS210 1 Connec tions and Pinou ts SDS1101/2 101 User G uide 81 Network Port The unit's back panel c ontains a 9 - 30VDC po wer plug and an RJ45 (10/ 100) Ethernet port.
SDS1101/2 101 User G uide 82 1 1 4 4 : : S S D D S S 1 1 1 1 0 0 1 1 T T e e c c h h n n i i c c a a l l S S p p e e c c i i f f i i c c a a t t i i o o n n s s Table 14 -1 .
14: SDS110 1 Technica l Specificat ions SDS1101/2 101 User G uide 83 Category Description Telnet lo gin DeviceIn staller software System Software DeviceIn staller, W in dows® 95/98/ME /NT/2000/XP - b.
SDS1101/2 101 User G uide 84 1 1 5 5 : : S S D D S S 2 2 1 1 0 0 1 1 T T e e c c h h n n i i c c a a l l S S p p e e c c i i f f i i c c a a t t i i o o n n s s Table 15 -1 .
15: SDS210 1 Technica l Specificat ions SDS1101/2 101 User G uide 85 Category Description Installab le Industrial Protocols ModBus T CP, ModBus A SCII/RTU , DF1 Multi - Mas ter (IAP version onl y ) Ma.
15: SDS210 1 Technica l Speci fic ations SDS1101/2 101 User G uide 86 Category Description transient o ver voltages Ethernet Port: 1500 V AC isolatio n shielded w ith shield c onnected to ch assis gro.
SDS1101/2 101 User G uide 87 A A : : A A l l t t e e r r n n a a t t i i v v e e W W a a y y s s t t o o A A s s s s i i g g n n a a n n I I P P A A d d d d r r e e s s s s Earlier cha pters descr ibe how to as sign a static IP addr ess using Dev iceInstaller, W eb Manager, and Setu p Mode (throu gh a Telnet or serial co nnection) .
A: Alter native Way s to Assign an IP Address SDS1101/2 101 User G uide 88 BOOTP Similar to DHCP, but f or smaller net works. Autom atically ass igns the IP ad dress f or a specif ic duration of time.
SDS1101/2 101 User G uide 89 B B : : B B i i n n a a r r y y t t o o H H e e x x a a d d e e c c i i m m a a l l C C o o n n v v e e r r s s i i o o n n s s Many of the unit’s conf iguration pr ocedures requ ire assem bling a series of options (repres ented as bits) into a complete c ommand ( represented as a byte).
B: Binar y to Hexadeci mal Conver sions SDS1101/2 101 User G uide 90 Scientif ic Calcul ator Another sim ple wa y to con vert binar y to hexadecim als is to use a scientific c alculator, such as the one availa ble on W indows’ operatin g systems . For example: 1.
SDS1101/2 101 User G uide 91 C C : : W W a a r r r r a a n n t t y y For details on the Lantr onix warr anty replacem ent policy, p lease go to our W eb site at www.
SDS1101/2 101 User G uide 92 D D : : C C o o m m p p l l i i a a n n c c e e a a n n d d D D i i s s c c l l a a i i m m e e r r Manufacturer’s Name & A ddress Lantronix 1 67 Techno logy Drive I.
D: Complianc e and Discl aimer SDS1101/2 101 User G uide 93 IEC 6100 0 -4- 11: 1994 RoHS Noti ce All Lantronix products in the following famil ies are China RoH S - com p liant and free of the followi.
D: Complianc e and Discl aimer SDS1101/2 101 User G uide 94 Manufacturer’s Contact 1 67 Techno logy Drive Irvine, C A 92618 USA Tol l Free: 800 - 526 - 87 66 Phone : 949 - 453 - 39 90 Fax: 949 - 450.
D: Complianc e and Discl aimer SDS1101/2 101 User G uide 95 Index Applicatio ns, 11 ARP and T elnet, 88 AutoIP, 17, 87 Binary to h exadecim al conversions , 89 BOOT P, 17, 88 Channel s ettings, 29, 4 .
SDS1101/2 101 User G uide 96 TF TP, 66 Troubles hooting, 9, 71 UDP sett ings, 3 5 W arranty, 91 W eb - Manager, 23.
デバイスLantronix SecureBox SDS1101の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Lantronix SecureBox SDS1101をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはLantronix SecureBox SDS1101の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Lantronix SecureBox SDS1101の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Lantronix SecureBox SDS1101で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Lantronix SecureBox SDS1101を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はLantronix SecureBox SDS1101の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Lantronix SecureBox SDS1101に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちLantronix SecureBox SDS1101デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。