INSTALLATION AND OPERATION MANUAL Model CI2000HT Shown RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE EPA CERTIFIED WOOD BURNING STOVE THIS APPLIANCE MUST BE INSTALLE D BY A QUALIFIED INSTALLER. READ ENTIRE MANUAL THOROUGHLY BEFORE INSTALLATION. P/N 775 , 080M ; Rev.
IMPORTANT WARNINGS PLEASE READ THIS ENTIRE MANUAL BEFORE YOU INSTALL AND USE YOUR NEW ROOM HEATER. FOR YOUR SAFETY, FOLLOW THE INSTALLATION, OPE RATION AND MAINTENANCE INSTRUCTIONS EXACTLY, WITHOUT DEVIATION. FAILURE TO FOLLOW THESE IN STRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURY, OR EVEN DEATH.
TABLE OF CONTENTS PAGE 3 Important Warn ings ................................................ 2 Testing/Listing, EPA, Using this Manual .................. 3 Planning Your Inst allation ..................................... 4-9 Installati on ..........
PLANNING YOUR INSTALLATION PAGE 4 QUESTIONS TO ASK LOCAL BUILDING OFFICIAL A correct installation is critical and imperative for reduc- ing fire hazards and perilous conditions that can arise when wood burning appliances are improperly installed. The installer must follow all of the manufacturers’ in- structions.
PLANNING YOUR INSTALLATION – Model CI1000HT PAGE 5 Top View FOR INSTALLATIONS IN THE USA MODEL CI1000H T FLOOR PROTECTION The floor protector must meet or exceed the minimum ther- mal requirements as defined on this page (see Floor Protec- tion Using Alternate Material As Floor Protector) .
PLANNING YOUR INSTALLATION – Model CI1000HT PAGE 6 Top View FOR INSTALLATIONS IN CANADA MODEL CI1000H T FLOOR PROTECTION The floor protector must meet or exceed the minimum ther- mal requirements as defined on this page (see Floor Pro- tection Using Alternate Material As Floor Protector) .
PLANNING YOUR INSTALLATION – Model CI2000HT PAGE 7 Top View FOR INSTALLATIONS IN THE USA & CANADA MODEL CI2000HT FLOOR PROTECTION The floor protector must meet or exceed the minimum ther- mal requirements as defined on this page (see Floor Protec- tion Using Alternate Material As Floor Protector) .
PLANNING YOUR INSTALLATION – Model CI1000HT PAGE 8 MODEL CI1000HT COMBUSTIBLE WALL CLEARANCE – USA & Canada WARNING: It is very im portant that you observ e the minimum clearances. There are listed clearances for your stove which were determined in a Laboratory test using various "classes" of stove pipe or chimney.
PLANNING YOUR INSTALLATION – Model CI2000HT PAGE 9 MODEL CI2000HT COMBUSTIBLE WALL CLEARANCE – USA & Canada WARNING: It is very im portant that you observ e the minimum clearances. There are listed clearances for your stove which were determined in a Laboratory test using various "classes" of stove pipe or chimney.
INSTALLATION PAGE 10 INSTALLING LEG PADS The four leg pads (included in accessory package), are provided for placement under the four legs. TYPES OF CHIMNEYS The unit must be connected to either a cod.
INSTALLATION PAGE 11 CHIMNEY INSPECTION Existing chimneys must be in spected before installing your stove. Consult your local building department for chimney code requirements. A masonry chimney must have a code approved liner. This liner must not have broken or missing pieces.
INSTALLATION PAGE 12 DRAFT REQUIREMENTS The appliance is merely one component of a larger system. The other equally im portant component is the venting system which is nec essary for achieving the required flow of combustion air to the fire chamber and for safely removing unwanted combustion byproducts from the appliance.
INSTALLATION See Pipe Manufacturers Instructions For Installation Requirements Of Venting Components And Vent Clearances. PAGE 13 SINGLE WALL PIPE Using 6” Diameter Single Wall Connector Pipe DOUBLE.
INSTALLATION – Combustible Wall Chimney Connector Pass-Throughs PAGE 14 1. Connectors to a masonry chimney, excepting method B, shall extend in one cont inuous section through the wall pass-through system and the chimney wall, to but not past the inner flue liner face.
CARE AND OPERATION PAGE 15 PRIMARY AIR DRAFT CONTROL Use the air control adjustment tool (provided) to adjust the air controls per the following instructions. Air Control / Ash Pan Removal Tool The primary combustion air delivery is controlled by the Primary Air Draft Control Assembly (located above the front door).
CARE AND OPERATION PAGE 16 HOW TO START AND MAINTAIN A FIRE 1. Using the Air Control Tool (provided), open the Start-Up Air Control (see Start-Up Air Control , on page 15). 2. Adjust the primary air draft control to the full open position (see Primary Air Draft Control on page 15).
CARE AND OPERATION PAGE 17 FRONT ASH REMOVAL DOOR AND SIDE FUEL LOAD- ING DOOR CAUTION: When opening the doors, do not extend them beyond their normal trav el. Overextending the doors to a further open position can put excessiv e stress on the hinge area of the doors w hich may result in breakage.
CARE AND OPERATION PAGE 18 FIRST FIRE NOTE: There is often an unpleasant odor and non- toxic fumes during the first initial burns (this is a natural result of the paint curing). We recommend that a w indow should be left open near the appliance during this curing process.
CARE AND OPERATION PAGE 19 BURN RECOMMENDED FUEL This appliance is designed for use with natural well- seasoned wood. Do not burn particleboard scraps or pressed logs because they can produce conditions which will deteriorate metal. Green or uncured wood does not work well as fuel, and can cause increased creosote buildups.
CARE AND OPERATION PAGE 20 SEASONING GUIDE Softwoods – 18 months Hardwoods – 18 months to 24 months This period can be shortened (12 to 15 months) if the wood is cut to the right length and imm ediately stored under a ventilated shelter.
MAINTENANCE PAGE 21 DO NOT CLEAN STOVE WHILE HOT INSPECT THE ENTIRE STOVE FREQUENTLY FOR PROPER OPERATION, FIT AND SOUNDNESS OF PARTS. IF ANY MALFUNCTIONING, CRACKED, BRO- KEN, OR LOOSE PARTS OR OTHER PROBLEMS ARE NOTED, CONTACT YOUR DEALER OR QUALIFIED SERVICEMAN TO INSPECT AND REPAIR THE UNIT.
MAINTENANCE PAGE 22 SERVICING GLASS CAUTION: BE CAREFUL NOT TO ABUSE DOOR ASSEMBLY BY STRIKING OR SLAMMING IT. IF THE DOOR ASSEMBLY OR GLASS IS BROKEN OR DAMAGED, THEY MUST BE REPLACED WITH FAC- TORY ORIGINAL PARTS BEFORE HEATER CAN BE SAFELY OPERATED.
MAINTENANCE / TROUBLESHOOTING PAGE 23 IN THE EVENT OF A CHIMNEY FIRE Make sure the fuel loading doors are securely closed. Adjust the primary air draft control to the low est (most closed) setting and ensure that the start-up air control is closed. Call the fire depart- ment immediately.
TROUBLESHOOTING PAGE 24 OVERFIRING DAMAGE If the heater or chimney connec tor glows, you are overfir- ing. Other symptoms may include: Cracking, warping or burning out of components, stove glass may develop a haze, which will not come off with cleaning.
SPECIFICATIONS - Model CI1000HT PAGE 25 Flue posit ion........................................ Top Flue collar size .................................... 6" (152 mm) Approx. burn time .............................. 6 to 8 hours Maximum burn ra te .
SPECIFICATIONS - Model CI2000HT PAGE 26 Flue posit ion........................................ Top Flue collar size .................................... 6" (152 mm) Approx. burn time .............................. 6 to 8 hours Maximum burn ra te .
REPLACEMENT PARTS - Models: CI1000HT & CI2000HT PAGE 27 PART # (ITEM #) DESCRIPTION WHERE USED See Note 40M5701 ( ♦ 31) Air Column Set, Left & Right (Includes Gaskets & Screw s) CI1000HT.
REPLACEMENT PARTS - Models: CI1000HT & CI2000HT PAGE 28 PART # (ITEM #) DESCRIPTION WHERE USED See Note 40M4501 Gasket Kit, 6 mm X 156cm (14979) For Air Intake Slide & Glass & 4 Ea. 6mm Glass Clip Gaskets (31856) CI1000HT & CI2000HT 40M0201 Gasket Kit, Ashpan Door Rope (8mm Dia.
REPLACEMENT PARTS - Models: CI1000HT & CI2000HT PAGE 29 ( ♦ 1) Front Firebox Door (CI1000HT & CI2000HT Series) ( ♦ 2) Side Loading Door (CI1000HT Series) ( ♦ 2) Side Loading Door (CI2000.
REPLACEMENT PARTS - Models: CI1000HT & CI2000HT PAGE 30 ( ♦ 10) Right Low er Firebrick (CI2000HT Series) ( ♦ 11) Upper Rear Firebrick (CI2000HT Series) ( ♦ 12) Left Firebrick (CI1000HT Series) ( ♦ 13) Low er Rear Firebrick (CI1000HT Series) ( ♦ 14) Right Firebrick (CI1000HT Series) 8.
REPLACEMENT PARTS - Models: CI1000HT & CI2000HT PAGE 31 ( ♦ 20) Fuel Grate Support Bar (CI1000HT Series) ( ♦ 21) Ash Removal Grate (CI1000HT Series) ( ♦ 22) Fuel Grate (CI1000HT Series) ( .
REPLACEMENT PARTS - Models: CI1000HT & CI2000HT PAGE 32 ( ♦ 32) Left Air Column Assembly (CI2000HT Series) ( ♦ 32) Right Air Column Assembly (CI2000HT Series) ( ♦ 33) Upper Air Deflector (CI.
REPLACEMENT PARTS - Models: CI1000HT & CI2000HT PAGE 33 ( ♦ 43) Secondary Air Tube Assembly (CI1000HT Series) ( ♦ 44) Secondary Air Tube Assembly (CI2000HT Series) ( ♦ 45) Air Control/Ash Pa.
OPTIONAL ACCESSORIES - Models: CI1000HT & CI2000HT PAGE 34 Catalog # Model Description Stove Model H0459 WTK-CI10 Window Trim Kit, Charcoal CI1000HT H0455 WTK-CI20 Window Trim Kit, Charcoal CI2000.
LABEL, SAFETY / LISTING – Model CI1000HT PAGE 35.
SAFETY/LISTING LABEL – Model CI2000HT PAGE 36.
EPA LABELS – CI1000HT and CI2000HT PAGE 37.
PAGE 38 OWNERSHIP RECORDS Dealer’s Name: Dealer’s Address: City: State: Zip Code: Serial Number: Date of Purchase: Date Installed: Notes: SERVICE AND MAINTENANCE LOG Service Service Service Date T.
.
Printed in U.S.A LENNOX HEARTH PRODUCTS 2002 P/N 775,080M Rev. F, 3/2005 1110 West Taft Avenue • Orange, CA 92865 LENNOX reserves the right to make changes at any time, without not ice, in design, materials, specifications, prices and also to di scontinued colors, styles and product s.
デバイスLenoxx Electronics CI2000HTの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Lenoxx Electronics CI2000HTをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはLenoxx Electronics CI2000HTの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Lenoxx Electronics CI2000HTの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Lenoxx Electronics CI2000HTで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Lenoxx Electronics CI2000HTを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はLenoxx Electronics CI2000HTの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Lenoxx Electronics CI2000HTに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちLenoxx Electronics CI2000HTデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。