S I T E M O N I T O R I N G ■ ■ ■ ■ ■ ■ ■ ■ MR1 Mini-Remote Environmental Monitor U SER M ANUAL.
.
TA BLE OF CONTENTS Section 1: INTRODUCTION .......................................................................................... 1 Specific ations ...................................................................................................
Figure 1. Typical System Configuration.
.
Section 1: INTRODUCTION The Liebert MR1 Mini-Rem ote m onitors the operating status and controls the operation of your Liebert Env ironmental unit. It serv es as a remote user interface, supplem enting the unit- front controls.
NOTE This equipment has been tested and found to comp ly with the lim its for a C lass A dig ital device, pursuant to part 15 of the FCC rules. These limits are designed to prov ide reasonable protection against harm ful interference when the equipment is operated in a com mercial environm ent.
Liebert MR1 • 3 Section 2: INSTA LLA TION Mounting The MR1 Mini-Rem ote is com pletely tested, then shipped from the factory disassem bled for your conv enience during installation.
Figure 2a. Flush-Mount Installation 4 • User Manual.
Electrical Connections The MR1 Mini-Rem ote requires a two- wire connection (field- supplied) to comm unicate with the Environm ental unit under its control. The stranded twisted-pair connects to the MR 1 interface board at TB2-11 (T+) and TB2- 12 (T-).
Figure 2b. Display Panel Mounted Remotely from Electrical Box 6 • User Manual.
Section 3: HA RDWA RE CONFIGURA TION DIP Switch Settings The following user selectable operations are set by DIP SW1 on the display panel circuit board: Refer to Table 2 and Figure 3. Position OFF ON 1 Audible beeper enabled Audible beeper disabled 2 Remote on/off disabled.
Figure 3. Electrical Connecti ons, Electric Box and Display 8 • User Manual.
Liebert MR1 • 9 Section 4: OPERA TION LCD and Keypad When power is first applied, the MR1 performs self- initialization and then enters the norm al display m ode. The display alternates between show ing the tem perature and humidity readings, and cooling/heating , de/humidification, and econocycle operating status.
button will turn on/off the unit being monitored and the MR 1. With DIP switch #2 in the OFF position, pressing the ON/OFF button will turn togg le the on/off operation of the MR1 only.
Setpoint AM/AG SM L10 L00 MM2 SSC On/Off ✔ ** ✔ ** ✔ ✔ Temperature ✔ ✔ ✔ ✔ ✔ Temp Sensitivity ✔ ✔ ✔ ✔ ✔ Hum idity ✔ ✔ ✔ ✔ ✔ Hum idity Sensitiv ity ✔ ✔ ✔ ✔.
Alarm AM/AG SM L10 L00 MM2 SSC High Tem perature ✔ ✔ ✔ ✔ ✔ ✔ Low Temperature ✔ ✔ ✔ ✔ ✔ ✔ High Humidity ✔ ✔ ✔ ✔ ✔ ✔ Low Humidity ✔ ✔ ✔ ✔ ✔ ✔ High Head Pr.
.
Mini-Remote Environmental Monitor ■ ■ ■ ■ ■ ■ ■ ■ MR1 T HE C OM PANY B EHIND T HE P RODUCT S W ith more than 500,000 installations around the globe, Liebert is the world leader in computer protection systems.
デバイスLiebert MR1の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Liebert MR1をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはLiebert MR1の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Liebert MR1の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Liebert MR1で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Liebert MR1を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はLiebert MR1の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Liebert MR1に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちLiebert MR1デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。