Page 1 of 2 Static, Flat Steel or Regressed Aluminum Lens Frame, 4 Lamp, T8

G Exposed T-grid ceiling. (with regressed aluminum frame)



Acoustical Material (By Others)
Acoustical Material (By Others)
Exposed T-bar (By Others)
Exposed T-bar (By Others)

3" x 1-1/2" Access Plate with 7/8" Hole and 7/8" Dia. K.O.
(2) 7/8" Dia. K.O.'s
Drywall kit (See Options)


Drywall Kit (See Options)
5/8" min. 2-13/16" max.
Job Name:
Cat. No.:
Lamp(s):
Volts/Ballast:

Page 2 of 2 Static, Flat Steel or Regressed Aluminum Lens Frame, 4 Lamp, T8
LER = FL - 74.3 IW - 112 BF - 0.88 Comparative yearly lighting energy cost per 1000 lumens = $3.23

coefficients of utilization — zonal cavity method (effective floor cavity reflectance 0.20)
RF 20 20 20 RC 80 50 30 RW 70 50 30 50 30 10 50 30 10 1 91 87 84 82 79 77 78 76 74 2 83 76 71 72 68 64 69 66 63 3 76 68 61 64 59 55 62 57 54 4 70 60 53 57 51 47 55 50 46 5 64 54 47 51 45 41 50 45 40 6 60 49 42 47 41 36 45 40 36 7 55 44 37 42 36 32 41 36 32 8 52 41 34 39 33 29 38 32 28 9 48 37 31 36 30 26 35 30 26 10 45 34 28 33 27 23 32 27 23 visual comfort probability (rated lumens per lamp 2850.)
25.0 41.0 70.0 83.0 00.0 83.0
030.0 050.0 084.0 100.0 000.0 100.0
83.0%
THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES • FIELD PERFORMANCE MAY VARY FROM LABORATORY PERFORMANCE.
VA
Lamp Quantity:
Fluorescent with Flat Steel Lens Frame XA = Recessed
(By others) 4 = 4-Lamp
Length:
T-bar F = Flanged
32=T8, 4' Length
(overlap) Z spline and plaster frame
Fluorescent with Regressed Aluminum Lens Frame
(standard) see options and consult factory
Options/Accessories Special Lens: Substitute VI for .125" nominal pattern. For other lenses, consult factory. Access Plates: Top wiring access plate is shipped with fixture as standard. When access plates are required in advance for wiring convenience, specify separately. Order Catalog number: ACPX CSP. Electrical Wiring Options: Consult factory. Fusing: Internal fast-blow fusing. Suffix: GLR.
Specifications (continued) Lens: Extruded virgin acrylic 3/16" square based female cones, running 45° to the panel edge. .095" nominal thickness (similar to pattern 12). Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. Labels: I.B.E.W./UL and ULc Listed.
Internal slow-blow fusing. Suffix: GMF. Radio Interference Filter: 120 or 277 volt, 50 or 60 Hz. One per fixture: Suffix: R. One per ballast: Suffix: B. Drywall Kit: Order Catalog Number: FK92x4 (Request Folio OA30-10).
Specifications Performance: In an installation of 4 lamps 32 W luminaires in a room cavity of 1, with reflectance of 80% ceiling, 50% walls, 20% floor, the C.U. shall not be less than .87. To control veiling reflections, luminaire output in the 30°-90° zone shall be not less than 70%. Materials: Chassis parts are die-formed code gauge cold rolled steel. Housing is embossed for added strength and rigidity with all edges turned over for safe handling. Lens frames—(XP) flat full-size steel frame, (XA) regressed full-size aluminum frame. Finish: Chassis exterior—white baked polyester enamel. Cavity—white baked polyester enamel minimum 86% reflectance. Phosphate undercoating.