Page 1 of 2 Static, 2' x 2', Recessed Fluorescent, Flat Steel Lens Frame (XP)

XA Exposed T-grid ceiling. XP Exposed T-grid ceiling.




15/16" Exposed T-bar by others
15/16" Exposed T-bar by others


Flat steel lens frame Regressed aluminum lens frame
Job Name:
Cat. No.:
Lamp(s):
Volts/Ballast:

Page 2 of 2 Static, 2' x 2', Recessed Fluorescent, Flat Steel Lens Frame (XP)
Photometry Model No. XP2GVA2FT120SB
LER = FL - 74.3 IW - 58 BF - 0.87 Comparative yearly lighting energy cost per 1000 lumens = $3.24

coefficients of utilization — zonal cavity method (effective floor cavity reflectance 0.20)
RF 20 20 20 RC 80 50 30 RW 70 50 30 50 30 10 50 30 10 1 92 85 89 83 81 78 80 78 76 2 85 78 73 74 70 66 71 68 65 3 78 69 63 66 61 56 63 59 55 4 72 62 55 59 53 49 57 52 48 5 66 56 49 53 47 43 52 46 42 6 61 51 43 48 42 38 47 42 37 7 57 46 39 44 38 34 43 37 33 8 53 42 35 40 34 30 39 34 30 9 50 39 32 37 31 27 36 31 27 10 47 36 29 35 29 25 34 29 25 visual comfort probability (rated lumens per lamp 2850.)
room size ceiling height ceiling height W L 8.5 10.0 13.0 16.0 8.5 10.0 13.0 16.0 20 20 53 57 65 74 51 55 62 70 20 30 46 50 54 62 43 47 52 59 20 40 43 45 49 54 39 42 46 51 20 60 40 42 45 49 35 38 41 45 30 20 55 58 64 71 53 57 62 69 30 30 47 50 54 60 45 48 52 57 30 40 43 45 48 52 39 42 46 50 30 60 39 42 43 47 35 38 40 44 30 80 38 40 41 44 34 36 37 40 40 20 56 60 65 71 55 59 64 69 40 30 49 52 55 59 46 50 53 57 40 40 44 45 49 52 41 44 47 50 40 60 40 42 44 47 36 39 40 44 40 80 38 40 40 43 34 36 37 40 40 100 38 39 39 41 34 35 35 38 60 30 49 53 55 60 48 52 54 58 60 40 45 47 49 52 42 45 48 51 60 60 40 43 44 47 37 40 41 44 60 80 38 40 40 43 35 37 37 40 60 100 38 39 38 41 34 35 35 37 100 40 47 50 51 55 46 48 50 54 100 60 43 45 45 49 41 43 43 47 100 80 41 42 42 44 38 39 39 42 100 100 39 40 39 42 36 37 36 38
THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES • FIELD PERFORMANCE MAY VARY FROM LABORATORY PERFORMANCE.
G 2 FT VA 2
Lamp Fixture Length:
Fluorescent with Flat Steel Lens Frame XA = Recessed
FT = Twin Tube (T5)
(standard) see options and consult factory
Fluorescent with Regressed Aluminum Lens Frame
Options/Accessories Special Lens: Substitute VY for .125" nominal pattern 12 with 7.8 oz. average weight per square foot. Substitute VI for .125" normal pattern 12 with 6.8 oz. average weight per square foot. Access Plates: Top wiring access plate is shipped with fixture as standard. When access plates are required in advance for wiring convenience, specify separately. Order Catalog Number: ACP CSP. Electrical Wiring Options: Consult factory. Fusing: Internal fast-blow fusing. Suffix: GLR. Internal slow-blow fusing. Suffix: GMF. Radio Interference Filter: 120 or 277 volt, 50 or 60 Hz. One per fixture: Suffix: R. One per ballast: Suffix: B. Drywall Kit: G type fixtures for drywall or plaster ceilings. Order Catalog Number: FK92X2.
Specifications (continued) Materials: Chassis parts are die-formed code gauge cold rolled steel. Lens frames— (XP) flat full-size steel frame, (XA) regressed full-size aluminum frame. Finish: Chassis exterior—white baked polyester enamel. Cavity—white baked polyester enamel minimum 86% reflectance. Phosphate undercoating. Lens: Extruded virgin acrylic 3/16" square based female cones, running 45° to the panel edge. .095" nominal thickness (similar to pattern 12). Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is with- in 3" of ballast, use wire suitable for at least 90°. Labels: I.B.E.W./UL and ULc Listed. This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org
Specifications Performance: In an installation of 2 lamps 40 W luminaires in a room cavity ratio of 1, with reflectance of 80% ceiling, 50% walls, 20% floor, the C.U. shall not be less than .89. To reduce glare the VCP shall not be less than 37 either lengthwise or crosswise (at 100 fc level) and the average brightness at 65 shall not exceed 3956 footlamberts. To control veil- ing reflections, luminaire output in the 30°-90° zone shall be not less than 68%.