LopiメーカーHorizontal Or Vertical Vent Freestanding Stove Yankee Pellet Stoveの使用説明書/サービス説明書
ページ先へ移動 of 42
Yankee Pellet Stove • Horizontal Or Vertical Vent • Freestanding Stove • Mobile Home Approved • Class A Chimney Retrofit • Hearth Stove into Existing Masonry Chimney , Masonry Fireplace, or Z.C. Fireplace Tested and Listed by Omni-Test Laboratories, Inc.
2 Introduction Travis Industries 4040714 100-01156 Introduction We welcome you as a new owner of a Yankee pellet heater. In purchasing a Yankee you have joined the growing ranks of concerned individuals whose selection of an energy system reflects both a concern for the environment and aesthetics.
Table of Contents 3 Travis Industries 4050418 100-01156 Introduction Introduction ......................................................2 Important Information .........................................2 Safety Precautions Safety Precautions ..........
4 Safety Precautions Travis Industries 4050418 100-01156 • Do not operate the heater if you smell smoke coming from the heater. Turn the M ODE switch to "OFF", monitor your heater, and call your dealer.
Table of Contents 5 Travis Industries 4050418 100-01156 • The heater will not operate during a power outage. If a power outage does occur, check the heater for smoke spillage and open a window if any smoke spills into the room. • This heater must be connected to a standard 115 V.
6 Specifications Travis Industries 4050418 100-01156 Heating Specifications: Approximate Maximum Heating Capacity (in square feet)* ........................................ 800 to 2,250 Sq. Feet Burn Rate (Pounds per Hour)** ..........................
Installation (For Qualified Installers Only) 7 Travis Industries 4050418 100-01156 Before You Begin READ THIS ENTIRE MANUAL BEFORE YOU INSTALL AND USE THIS HEATER. FAILURE TO FOLLOW THE INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURY, OR EVEN DEATH.
8 Installation (For Qualified Installers Only) Travis Industries 4050418 100-01156 Clearances - Straight Installation 6 ” Minimum 3 ” Minimum 9 ” Minimum 3 ” Minimum Through the Wall Installat.
Installation (For Qualified Installers Only) 9 Travis Industries 4050418 100-01156 Venting the Pellet Stove • PELLET VENT MUST MAINTAIN A MINIMUM 3" CLEARANCE TO ANY COMBUSTIBLE (INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER). • DO NOT CONNECT THE PELLET VENT TO A VENT SERVING ANY OTHER APPLIANCE OR STOVE.
10 Installation (For Qualified Installers Only) Travis Industries 4050418 100-01156 Pellet Vent Type • Must be 4" diameter Type "L" (except for masonry fireplace installations) - or - connect the vent to a factory built type "A" chimney.
Installation (For Qualified Installers Only) 11 Travis Industries 4050418 100-01156 Mobile Home Requirements • Outside air is required (used for combustion) - see the directions below. • The heater must be bolted to the floor (Some states do not require this; check with your local building department).
12 Installation (For Qualified Installers Only) Travis Industries 4050418 100-01156 Alcove Installation Requirements When the pellet stove is placed in a location where the ceiling height is less than 7' tall, it is considered an alcove installation.
Installation (For Qualified Installers Only) 13 Travis Industries 4050418 100-01156 Installation Example: Direct "Through-the-wall" Installation 3 ” Minimum 9 ” Minimum Floor Protection .
14 Installation (For Qualified Installers Only) Travis Industries 4050418 100-01156 Installation Example: Interior Vertical Installation Type "L" Vent 6 ” Minimum 3 ” Minimum Floor Protection 2 ” Minimum 9 ” Minimum “ Tee ” Outside Air (optional) Floor Protection 24 ” Minimum Insulation must maintain 3 ” clearance.
Installation (For Qualified Installers Only) 15 Travis Industries 4050418 100-01156 Installation Example: Class A Chimney Retrofit Type "L" Vent 6 ” Minimum 3 ” Minimum Floor Protection 2 ” Minimum 9 ” Minimum “ Tee ” Outside Air (optional) Floor Protection Outside air may be drawn from a ventilated crawl space.
16 Installation (For Qualified Installers Only) Travis Industries 4050418 100-01156 Installation Example: Masonry Fireplace Hearth Stove “ L ” Vent Flex Section Outside air may be drawn from the ash cleanout. 6 ” Min. “ L ” Vent Storm Collar Vertical Cap Cover Plate (non-combustible) Silicone Seal the cover plate with silicone.
Installation (For Qualified Installers Only) 17 Travis Industries 4050418 100-01156 Installation Example: Zero-Clearance (Metal) Fireplace Hearth Stove “ L ” Vent Flex Section 6 ” Min. “ L ” Vent Storm Collar Vertical Cap Cover Plate (non-combustible) Silicone Seal the cover plate with silicone.
18 Installation (For Qualified Installers Only) Travis Industries 4050418 100-01156 Installation Example: Freestanding Masonry Chimney “ L ” Vent Sections 6 ” Min. “ L ” Vent Storm Collar Vertical Cap Cover Plate (non-combustible) Silicone Seal the cover plate with silicone.
Operation 19 Travis Industries 4050418 100-01156 Safety Notice Read this entire manual (especially the "Safety Precautions" on pages 4 and 5) before using this stove. Failure to follow the instructions may result in property damage, bodily injury, or even death.
20 Operatio n Travis Industries 4050418 100-01156 Loading Pellets Lift the hopper lid to its vertical position. Pour pellets into the hopper until full. Make sure pellets are not left on this heat shield. P e t e l s l To Close the Hopper Lid: lift the lid, pull this bar forward, then lower the lid down.
Operation 21 Travis Industries 4050418 100-01156 Manual Mode Manual mode requires the user to turn the heater on and off manually. To Start Press the "Manual Start" button. That's it. The stove automatically goes to a medium burn rate and high fan while the igniter starts the fire burning within 10 minutes.
22 Operation Travis Industries 4050418 100-01156 Auto Mode Auto mode allows you to use a thermostat to control room temperature. The stove automatically turns on when the temperature drops below the thermostat setting. Once the stove reaches operating temperature, the stove then runs at the heat output setting selected.
Operation 23 Travis Industries 4050418 100-01156 Restrictor Adjustment The exhaust restrictor “ fine tunes ” your appliance, adjusting the amount of air flowing to the flame. NOTE : the optimal restrictor position will vary over time as soot builds up inside the exhaust system.
24 Operation Travis Industries 4050418 100-01156 Start-Up Sequence This stove utilizes a start-up sequence whenever the mode switch is changed or the heater is started when cold. This is to ensure proper operation through all possible settings and operational states (hot or cold, pellets burning or not burning, etc.
Maintenance 25 Travis Industries 4050418 100-01156 Daily Maintenance (whenever using the stove) Inspect the Burn When burning on high, the flames should be bright orange with embers jumping from the firepot. NOTE : the optimal restrictor position will vary over time as soot builds up inside the exhaust system.
26 Maintenance Travis Industries 4050418 100-01156 Daily Maintenance (whenever using the stove) - Continued Check Firepot for Clinkers If the flames seem to be coming only from the sides, or are orange/black, turn the heater off and check for clinkers.
Maintenance 27 Travis Industries 4050418 100-01156 Door Opening WARNING : Make sure the heater has fully cooled (approximately 25 minutes) before opening the door. When securing the door, make sure the pawl fits over the bracket before tightening. NOTE : Do not overtighten the pawl.
28 Maintenance Travis Industries 4050418 100-01156 Bi-Weekly Maintenance (or every 10 bags of pellets) Clean the Heat Exchange Tubes WARNING: The front edge of the hopper lid becomes very hot, do not touch the area below the handle. With the stove cool (or using the door latch tool), move the heat exchange cleaner up and down several times.
Maintenance 29 Travis Industries 4050418 100-01156 Bi-Weekly Maintenance (or every 10 bags of pellets) - Continued Clean the Baffles Lift the left side baffle up and move it towards the front of the stove. Rotate the back of the baffle forward. b c d e The baffle rests on this ledge at the back of the firebox.
30 Maintenance Travis Industries 4050418 100-01156 Sweep Ash Into Ashpan HINT: The more often you clean out the flyash, the more efficient your heater will burn. Swing the side ash trap door up. Lift it up and away from the firebox. Repeat for the opposite side.
Maintenance 31 Travis Industries 4050418 100-01156 Bi-Weekly Maintenance (or every 10 bags of pellets) - Continued Check Ashpan, Dispose if necessary NOTE : When replacing the ash pan make sure it is pushed all the way in. The ash pan has a built in handle to ease transportation of the ashes.
32 Maintenance Travis Industries 4050418 100-01156 Yearly Maintenance (or every two tons) WARNING: Disconnect the power cord prior to conducting service.
Maintenance 33 Travis Industries 4050418 100-01156 Yearly Maintenance (or every two tons) - Continued Clean the Exhaust Blower (make sure the stove is cool and unplugged) Restrictor Knob a Open the hopper lid and remove the screw holding the left door in place.
34 Maintenance Travis Industries 4050418 100-01156 Yearly Maintenance (or every two tons) - Continued Door Seal ! Air leaks into the firebox will decrease the stove's performance greatly, leading to excessive sooting, inefficient burning, and perhaps a malfunction.
Maintenance 35 Travis Industries 4050418 100-01156 Adjusting the Door Hinge and Latch • The door hinge and door latches may be adjusted to pull the door closer to the body. The illustration below details how to adjust these components. NOTE: Make sure to read the section "Door Alignment" on the previous page before adjusting the door.
36 Maintenance Travis Industries 4050418 100-01156 Check for Air Leaks Around the Door, Glass, and Ashpan ! Air leaks into the firebox will decrease the stove's performance greatly, leading to excessive sooting, inefficient burning, and perhaps a malfunction.
Normal Operating Sounds 37 Travis Industries 4050418 100-01156 Auger Motor When feeding pellets, you may hear the intermittent buzz of this motor running. Convection Fan The modern high efficiency fan may produce a low hum, particularly on "HIGH".
38 Safety Label Travis Industries 4050418 100-01156 W ARNING - DO NOT REMOVE OR COVER THIS LABEL Listed Pelletized Solid Fuel Burning Appliance Also for Use in Mobile Homes Model: Y ankee PS Serial No.
Limited 7 Year Warranty 39 Travis Industries 4050418 100-01156 To register your TRAVIS INDUSTRIES, INC. 7 Year Warranty, complete the enclosed warranty card and mail it within ten (10) days of the appliance purchase date to: TRAVIS INDUSTRIES, INC., 4800 Harbour Pointe Blvd.
40 Optional Equipment Travis Industries 4050418 100-01156 Thermostat (Part # 99300650) ! Do not connect 120 VAC to the thermostat circuit of this heater (do not use a household thermostat used for a wall-board or other electical heater). 1 Attach the thermostat wire to the circuit board (see the illustration to the right).
Optional Equipment 41 Travis Industries 4050418 100-01156 Remote Thermostat • Follow the instructions included with the remote thermostat for installation. Using the Remote Thermostat The remote thermostat has a 1 to 2 minute lag time between the time the thermostat is turned up and the heater turns on.
42 Index Travis Industries 4050418 100-01156 Adjusting the Fan Speed ......................................2 3 Air Leaks ..........................................................3 6 Alcove Installation Requirements ..........................1 2 Ashpan (Opening and Disposing Ashes) .
デバイスLopi Horizontal Or Vertical Vent Freestanding Stove Yankee Pellet Stoveの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Lopi Horizontal Or Vertical Vent Freestanding Stove Yankee Pellet Stoveをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはLopi Horizontal Or Vertical Vent Freestanding Stove Yankee Pellet Stoveの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Lopi Horizontal Or Vertical Vent Freestanding Stove Yankee Pellet Stoveの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Lopi Horizontal Or Vertical Vent Freestanding Stove Yankee Pellet Stoveで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Lopi Horizontal Or Vertical Vent Freestanding Stove Yankee Pellet Stoveを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はLopi Horizontal Or Vertical Vent Freestanding Stove Yankee Pellet Stoveの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Lopi Horizontal Or Vertical Vent Freestanding Stove Yankee Pellet Stoveに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちLopi Horizontal Or Vertical Vent Freestanding Stove Yankee Pellet Stoveデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。