Leyden Pellet Stove • Horizontal Or Vertical Vent • Freestanding Stove • Mobile Home Approved • Class A Chimney Retrofit • Hearth Stove into Existing Masonry Chimney , Masonry Fireplace, or Z.C. Fireplace Tested and Listed by Omni-Test Laboratories, Inc.
2 Introduction Travis Industries 4061016 100-01184 Introduction Congratulations! You have just purchased one of the finest hearth products on the market. Lopi heating appliances are solidly crafted and uniquely designed for the American lifestyle and proudly built in the U.
Table of Contents 3 Travis Industries 4061016 100-01184 Introduction Introduction ......................................................2 Important Information .........................................2 Safety Precautions Safety Precautions ..........
4 Safety Precautions Travis Industries 4061016 100-01184 • Do not operate the heater if you smell smoke coming from the heater. Turn the M ODE switch to "OFF", monitor your heater, and call your dealer.
Safety Precautions 5 Travis Industries 4061016 100-01184 • The heater will not operate during a power outage. If a power outage does occur, check the heater for smoke spillage and open a window if any smoke spills into the room. • This heater must be connected to a standard 115 V.
6 Specifications Travis Industries 4061016 100-01184 Heating Specifications Approximate Maximum Heating Capacity (in square feet)* ........................................ 800 to 2,250 Sq. Feet Burn Rate (Pounds per Hour)** ...........................
Installation (For Qualified Installers Only) 7 Travis Industries 4061016 100-01184 Before You Begin READ THIS ENTIRE MANUAL BEFORE YOU INSTALL AND USE THIS HEATER. FAILURE TO FOLLOW THE INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURY, OR EVEN DEATH.
8 Installation (For Qualified Installers Only) Travis Industries 4061016 100-01184 Clearances - Straight Installation 7 ” Minimum 6 ” Minimum 3 ” Minimum 2 ” Minimum “ Tee ” 3 ” Minimum .
Installation (For Qualified Installers Only) 9 Travis Industries 4061016 100-01184 Venting the Pellet Stove • PELLET VENT MUST MAINTAIN A MINIMUM 3" CLEARANCE TO ANY COMBUSTIBLE (INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER). • DO NOT CONNECT THE PELLET VENT TO A VENT SERVING ANY OTHER APPLIANCE OR STOVE.
10 Installation (For Qualified Installers Only) Travis Industries 4061016 100-01184 Pellet Vent Type • Must be 4" diameter Type "L" (except for masonry fireplace installations) - or - connect the vent to a factory built type "A" chimney.
Installation (For Qualified Installers Only) 11 Travis Industries 4061016 100-01184 Mobile Home Requirements • Outside air is required (used for combustion) - see the directions below. • The heater must be bolted to the floor (Some states do not require this; check with your local building department).
12 Installation (For Qualified Installers Only) Travis Industries 4061016 100-01184 Alcove Installation Requirements When the pellet stove is placed in a location where the ceiling height is less than 7' tall, it is considered an alcove installation.
Installation (For Qualified Installers Only) 13 Travis Industries 4061016 100-01184 Thermostat Installation ! Do not connect 120 VAC to the thermostat circuit of this heater (do not use a household thermostat used for a wall-board or other electical heater).
14 Installation (For Qualified Installers Only) Travis Industries 4061016 100-01184 Installation Example: Direct "Through-the-wall" Installation Floor Protection House Shield (used to protec.
Installation (For Qualified Installers Only) 15 Travis Industries 4061016 100-01184 Installation Example: Interior Vertical Installation Floor Protection 24 ” Minimum Insulation must maintain 3 ” clearance. Outside air may be drawn from a ventilated crawl space.
16 Installation (For Qualified Installers Only) Travis Industries 4061016 100-01184 Installation Example: Class A Chimney Retrofit Floor Protection Outside air may be drawn from a ventilated crawl space.
Installation (For Qualified Installers Only) 17 Travis Industries 4061016 100-01184 Installation Example: Masonry Fireplace Hearth Stove “ L ” Vent Flex Section Outside air may be drawn from the ash cleanout. 6 ” Min. “ L ” Vent Storm Collar Vertical Cap Cover Plate (non-combustible) Silicone Seal the cover plate with silicone.
18 Installation (For Qualified Installers Only) Travis Industries 4061016 100-01184 In s t al l at i o n E x am p l e: Z er o -Cl ear an c e (M et al ) F i r ep l ac e H ear t h S t o v e “ L ” Vent Flex Section 6 ” Min. “ L ” Vent Storm Collar Vertical Cap Cover Plate (non-combustible) Silicone Seal the cover plate with silicone.
Installation (For Qualified Installers Only) 19 Travis Industries 4061016 100-01184 Installation Example: Freestanding Masonry Chimney 6 ” Min. Allow room for the hopper lid to open 44 ” “ L ” Vent Sections “ L ” Vent Storm Collar Vertical Cap Cover Plate (non-combustible) Silicone Seal the cover plate with silicone.
20 Operation Travis Industries 4061016 100-01184 Safety Notice Read this entire manual (especially the "Safety Precautions" on pages 4 and 5) before using this stove. Failure to follow the instructions may result in property damage, bodily injury, or even death.
Operation 21 Travis Industries 4061016 100-01184 Loading Pellets Lift the hopper lid to its vertical position. Pour pellets into the hopper until full. NOTE: The hopper holds approximately 50 pounds of pellets. To Open the Hopper Lid: Lift the hopper lid from this handle.
22 Operation Travis Industries 4061016 100-01184 Manual Mode Manual mode requires the user to turn the heater on and off manually. To Start Press the "Manual Start" button. That's it. The stove automatically goes to a medium burn rate and high fan while the igniter starts the fire burning within 10 minutes.
Operation 23 Travis Industries 4061016 100-01184 Auto Mode Auto mode allows you to use a thermostat to control room temperature. The stove automatically turns on when the temperature drops below the thermostat setting. Once the stove reaches operating temperature, the stove then runs at the heat output setting selected.
24 Operation Travis Industries 4061016 100-01184 Restrictor Adjustment The restrictor “ fine tunes ” your appliance, adjusting the amount of air flowing to the flame. NOTE : the optimal restrictor position will vary over time as soot builds up inside the exhaust system.
Operation 25 Travis Industries 4061016 100-01184 Start-Up Sequence This stove utilizes a start-up sequence whenever the mode switch is changed or the heater is started when cold. This is to ensure proper operation through all possible settings and operational states (hot or cold, pellets burning or not burning, etc.
26 Operation Travis Industries 4061016 100-01184 Using a Pellet/Corn Mix with This Heater This heater may burn a mixture of corn and wood pellets up to a 50% - 50% proportion by volume. Shelled corn burned in Travis pellet appliances must be clean (free of husk and cob residue) and have a moisture content no greater than 15%.
Maintenance 27 Travis Industries 4061016 100-01184 Daily Maintenance (whenever using the stove) Inspect the Burn When burning on high, the flames should be bright orange with embers jumping from the firepot. NOTE : the optimal restrictor position will vary over time as soot builds up inside the exhaust system.
28 Maintenance Travis Industries 4061016 100-01184 Daily Maintenance (whenever using the stove) - Continued Check Firepot for Clinkers If the flames seem to be coming only from the sides, or are orange/black, turn the heater off and check for clinkers (ashes that solidify into a clump).
Maintenance 29 Travis Industries 4061016 100-01184 Daily Maintenance (whenever using the stove) - Continued Door Opening WARNING : Make sure the heater has fully cooled (approximately 25 minutes) before opening the door and conducting service. Open the latch.
32 Maintenance Travis Industries 4061016 100-01184 Bi-Weekly Maintenance (or every 10 bags of pellets) Flyash Removal This heater was designed to allow for easy flyash removal with the included tools. However, to ease maintenance, several pellet stove owners have purchased vacuums specifically made to remove flyash.
Maintenance 31 Travis Industries 4061016 100-01184 Bi-Weekly Maintenance (or every 10 bags of pellets) - continued Clean the Baffles WARNING : Make sure the heater has fully cooled (approximately 25 minutes) before conducting service. HINT : The more often you clean out flyash, the more efficient your heater will burn.
32 Maintenance Travis Industries 4061016 100-01184 Bi-Weekly Maintenance (or every 10 bags of pellets) - continued Sweep Ash Into Ashpan WARNING : Make sure the heater has fully cooled (approximately 25 minutes) before conducting service. Remove the two ashdump covers on the floor of the firebox using the included hook tool.
Maintenance 33 Travis Industries 4061016 100-01184 Bi-Weekly Maintenance (or every 10 bags of pellets) - continued Check Ashpan, Dispose if necessary WARNING : Make sure the heater has fully cooled (approximately 25 minutes) before conducting service.
34 Maintenance Travis Industries 4061016 100-01184 Yearly Maintenance (or every two tons) The following section details extensive maintenance procedures. We strongly suggest these items be carried out by a trained service technician, possibly by a service agreement set up with your dealer.
Maintenance 35 Travis Industries 4061016 100-01184 Yearly Maintenance (or every two tons) - continued Remove the button plugs at the top of the firebox (both sides). Once removed, use the bottle brush to dislodge any flyash from the exhaust channel behind the button plug.
36 Maintenance Travis Industries 4061016 100-01184 Yearly Maintenance (or every two tons) - continued Clean the Exhaust Blower The exhaust blower cover is held in place with 4 screws. Remove the cover plate on the exhaust blower. Clean the area inside the blower, removing all flyash.
Maintenance 37 Travis Industries 4061016 100-01184 Yearly Maintenance (or every two tons) - continued Clean the Convection Blower Remove all dust and debris from the convection blower. Take care to prevent damage to the convection blower impellers. Clean the Vent Check the vent sections for creosote accumulation (indicating a poorly burning stove).
38 Maintenance Travis Industries 4061016 100-01184 Replacement Parts Door Replacement Parts 5 9 8 10 4 3 7 2 6 1 ID # Description Qty Part # ID # Description Qty Part # 1 Door, Left 1 2 Door, Right 1 .
Normal Operating Sounds 39 Travis Industries 4061016 100-01184 Auger Motor When feeding pellets, you may hear the intermittent buzz of this motor running. Heat Exchanger Tubes You may hear the heated air being forced through these tubes by the convection fan.
40 Safety Label Travis Industries 4061016 100-01184.
Limited 7 Year Warranty 43 Travis Industries 4061016 100-01184 To register your TRAVIS INDUSTRIES, INC. 7 Year Warranty, complete the enclosed warranty card and mail it within ten (10) days of the appliance purchase date to: TRAVIS INDUSTRIES, INC., 4800 Harbour Pointe Blvd.
42 Index Travis Industries 4061016 100-01184 "AUGER ON" Light ..............................................2 5 "FAULT" Light ....................................................2 5 "MANUAL AUGER" Button .................
デバイスLopi Leyden Pellet Stoveの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Lopi Leyden Pellet Stoveをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはLopi Leyden Pellet Stoveの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Lopi Leyden Pellet Stoveの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Lopi Leyden Pellet Stoveで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Lopi Leyden Pellet Stoveを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はLopi Leyden Pellet Stoveの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Lopi Leyden Pellet Stoveに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちLopi Leyden Pellet Stoveデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。