1 Pub. 988-0154-442 EP-80R TH Electronic Thru-Hull Temp Sensor Installation and Configuration Instructions This document shows how to install an EP-80R TH thru-hull temp sen- sor and how to connect it to a NMEA 2000 ® network.
2 Some sonar or GPS units may require a software upgrade to display NMEA 2000 data correctly. For free software upgrades or additional information on the LowranceNet NMEA 2000 ® network system, visit our web site, www.
3 LowranceNET Node Kit for a NMEA 2000 network. Includes a 2-foot extension cable, T connector and two 120-ohm terminators. Recommended Tools and supp lies Recommended tools for this job include: drill, 1/8" (3 mm) drill bit for pilot hole, 1-1/16 (27 mm) hole saw with a blade type appropriate for the com- position of your transom.
4 Afterwards, clean the area around th e hole with detergent or alcohol. This will establish a good surface for the adhesive. 5. Using a high quality, marine-g rade above- or below-waterline seal- ant/adhesive compound, apply a 1/8" (3 mm ) bead of sealant around the lip of the EP-80R TH housing.
5 Cross section of transom showing EP-80R TH installed . Connecting to a NMEA 2000 Network A NMEA 2000 network is a communications link between two or more devices that transfer NMEA 2000 in formation. LowranceNET is the NMEA 2000 networking system develo ped by Lowrance Electronics.
6 Network Backbone and Network Nodes A network bus backbone consists of network cabling, terminators and T connectors. Network nodes are made by fitting T-shaped connectors into the backbone (using the sockets on the sides) and attaching any network device to the bottom of the T.
7 All T connectors on your network pro bably will be connected to a device. If you want to add another node to a working network, add another T connector. T connectors may be purch ased from LEI (ordering informa- tion appears on the back page of this booklet).
8 Notes.
9 LMF-200: EP-80R TH Temp Configuration This section will show you how to use the LMF-200 Multi-function gauge to configure your EP- 80R TH Temperature Sensor. NOTE: You will notice the LMF-200 does not have an Exit key. Menus will time out after a preset amount of time (3, 5, 10 or 15 seconds).
10 3. If you selected a configuration with more than one tank you will have to select the tank you want to set up and press MENU , which will open the Tank Size window. (If you choos e a single-tank configuration, you will not have to choose the tank.
11 To unconfigure a temp sensor: 1. Press MENU , use the UP and DOWN k e y s t o s e l e c t S YSTEM S ETUP and press MENU . 2. Highlight B. D EVICES and press MENU , which will open the Bus Devices list. 3. Select a temp sensor from the Bus Devices list and press MENU .
12 7. Select R ECONFIG and press MENU to open the Selecting Temp menu. Highlight W ATE R and press MENU . You will be directed to the Bus De- vices list. 8. Highlight U N C FG T EMP and press MENU . The following message will appear: Hit Menu to Cfg Temp Sns .
13 Customizing Pages The customizing pages feature allows you to choose what data will be displayed and how it will be displayed on select pages. You can custom- ize the Gauge, Single Digital and Dual Digital pages with temp sensor data. To customize Gauge pa ge: 1.
14 Notes.
15 LMF-400: EP-80R TH Temp Configuration This section will show you how to use the LMF-400 Multi-function gauge to configure your EP- 80R TH Temperature Sensor.
16 5. After all tanks on your vesse l have been set up, press EXIT repeatedly to return to the main display. Boat Setup Reset If you want to access the Setup scr een (Boat Setup) after an engine- tank configuration has been chosen you will have to reset the configu- ration to default settings.
17 3. Choose the desired temp sensor and press ENTER . Select U NCONFIGURE from the temp configuration menu and press ENTER . The following message will appear: Press Menu to UnConfig Device Name . 4. Press ENTER to unconfigure the sensor and be directed to the Bus Devices list where the temp now will be listed as UnCfg Temp.
18 configuration menu. Select R ECONFIGURE and press ENTER . That will di- rect you to the Temp Selection menu, which will have three options: Water, Outside and Inside. 6. Select O UTSIDE and press ENTER . You will be taken back to the Bus Devices list.
19 To add a page to the dis play: 1. Press MENU , use the UP and DOWN k ey s t o s el ec t P AGE S and press EN- TER . A menu will pop up with four options: Add Page, Remove Page, Page Scrolling and Pop-Ups Setup. 2. Select A DD P AGE and press ENTER .
20 5. Highlight T EMPERATURE and press ENTER . The Select Temp menu will appear with three temp types: Wa ter Temp, Outside Temp and Inside Temp. 6. Select the desired temp type and press ENTER . You will be directed to the Position menu. Repeat steps 4 and 5 to customize the other posi- tion, or press EXIT twice to return to the main display.
21 4. Select T EMPERATURE and press ENTER . The Select Temp menu will ap- pear with three temp types: Wate r Temp, Outside Temp and Inside Temp. 5. Select the desired temp type and press ENTER . You will be directed to the Position menu. Repeat steps 3 through 5 to customize the other po- sition, or press EXIT twice to return to the main display.
22 Notes.
23 Display Unit: EP-80R TH Temp Configuration All NMEA 2000 capable Lowrance sonar and sonar/GPS combo display units can be used to configure your EP-80R TH thru-hull temp sensor on a NMEA 2000 network. The LMS-525cDF is one of many Lowrance display units that may be used to configure an EP-80R TH thru-hull temp sensor.
24 Bus Setup highlighted on the NMEA 2000 menu (left). Bus Setup se- lected on Networking menu (right). EP-80R TH Temp Sensor Configuration The Temp Type function will be used when configuring your temp sen- sor through a display unit. You will se lect a configuration name for the temp from the Temp Type menu.
25 4. Press ENTER . Use the arrow keys to input the desired name for the temp sensor and press ENTER . Press EXIT repeatedly to return to the main display. To reset device name to default setting: 1. Press MENU twice, select NMEA 2000 or N ETWORKING and press ENTER .
26 Unconfiguring a Temp Sensor You could unconfigure a temp sensor by changing its temp type to un- known or you can use the Restore Defaults command, which will reset the temp type and device name to default settings. To restore default se ttings : 1.
27 Displaying EP-80R TH Temp Sensor Information The Overlay Data function will be used to show temp sensor data on your unit's main display. NOTE : Make sure your temp sensor has b een configured before attempting to display temperature data on your display unit.
28 Notes.
29 Notes.
30 Notes.
31 LOWRANCE ELECTRONICS FULL ONE-YEAR WARRANTY "We," "our," or "us" refers to LOWRAN CE ELECTRONICS, INC., the manufacturer of this product. "You" or "your" refers to the first person wh o purchases this p roduct as a consumer item for personal, family or household use.
32 How to Obtain Service… …in the USA: Contact the Factory Customer Se rvice Department. Call toll-free: For Lowrance: 800-324-1356. For Eagle: 800-324-1354 8 a.
デバイスLowrance electronic EP-80R THの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Lowrance electronic EP-80R THをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはLowrance electronic EP-80R THの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Lowrance electronic EP-80R THの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Lowrance electronic EP-80R THで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Lowrance electronic EP-80R THを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はLowrance electronic EP-80R THの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Lowrance electronic EP-80R THに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちLowrance electronic EP-80R THデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。