Lowrance electronicメーカーX-16の使用説明書/サービス説明書
ページ先へ移動 of 16
________________ — . '•• 'I INSTALLATION ANID OPERATION MANUAL X-16 OWNER'S MANUAL Litho in U.S.A. 988-0096-09 • LOWRANCE ELECTRONICS, INC. .12000 E. SKELLY DR., TULSA, OKLA. 74128 NOTICE Periodically wash the Trans- ducer Face with soap and water to remove any oil film that may collect.
SURFACE CLUTTER Algae, plankton, air bubbles, boat wakes, and schools of bait fish near the surface of the water can create large surface echoes on the paper.
the sonar can separate two tar- gets that are 11/2 inches apart. This is considered good resolution. However, if a sonar' pulse length was 500 micro-seconds, then the sonar could only separate targets that are at least 12 inches apart.
INTRODUCTION The Lowrance X-16 is a highly sophisticated recording depth sounder Thanks to a micro-com- puter, the X-16 can do more than any other sonar unit in its price range plus many that cost much more.
be used to help alleviate this condition. LORAN-C INTERFACE A remarkable advantage of the X-16 is its ability to print Loran-C coordinates in either Time Differen- ces (ID's) or Latitude and Longi- tude. (NOTE: The X-16 has been designed to use only the Lowrance Loran-C receiver.
cable in the event a short occurs. Crimp connectors are supplied to attach the fuse holder to the power cable. The red wire in the power cable is the positive con- ductor The black wire is the ground or negative conductor. The graph is protected from accidental polarity reversals and no damage will occur if the wires are reversed.
keyboard the initial pulse length desired and then press the PULSE key. For example, to set the initial transmit pulse length to 1 00 micro- seconds, press 1 - 0 - 0 - PULSE. This will override the micro-com- puter's selection and set the initial transmitter pulse length to 100 micro-seconds.
Recording individual fish with an "arched" signature can usually be accomplished at trolling speed with the Sensitivity knob at the ¾ point, or higher. Refer to the section 'Arched Signatures" for more information about this impor- tant function of the recorder.
selected, the transmit pulse length would be: 525 + 200 = 725 micro-seconds. We added the ini- tial transmit pulse of 525 micro- seconds which is listed in the initial transmit pulse chart, to 200 micro-seconds, which is Sup- pressor level 3, according to the Discrimination - Suppressor chart.
used to outline the bottom contour which might otherwise be hidden beneath trees and brush; it can also give clues to the composition of the bottom. A hard bottom returns a very strong signal caus- ing a wide gray line. A soft, muddy or weedy bottom returns a weaker signal which is emphasized with a narrow gray line.
0:THH t; H' j/ 'yL j/'11 if, FIGURE 40 graph record becomes coarse and the ability to separate fish from the bottom or from other fish will be decreased. (See Figure 41 & 42.) Therefore, the lower the suppression setting, the better.
12.0 24.0 26.0 49.0 60.0 Ft 21 L0IJRAHCE FIGURE 16 MARKER An event marker function is included in the X-1 6 so that events may be marked when desired. To use the marker, simply press the MARK key and a vertical line will be displayed across the entire page.
washed periodically with mild soapy water to remove any accu- mulated road grime or oily film. This is essential to have good contact between the transducer and the water. Periodically, the rubber roller on the paper drive should be cleaned with a cloth dampened with alco- hol to improve the friction on the metering roller drive.
place near the top of the chart paper. A zero adjust control has been placed on the back inside wall of the X-1 6 near the upper left hand corner so that the zero line position may be adjusted on the paper. Open the case front and look for the decal marked "ZERO ADJUST".
10. Push the transport assembly back to its operating position. Be sure it engages the catch inside the case. 11. Close the front of the case. Latch both catches on the top. 12. Turn the unit on. Move the Chart Speed knob fully clock- wise. Watch the paper long enough to be sure it is moving smoothly and evenly across the platen.
Special Note: The stylus may be damaged if the transport assembly is pulled down unless the stylus has been moved to the back side of the platen. 4. Pull out and down on the tab at the top center of the platen assembly to expose the paper spools. (See Figure 26).
デバイスLowrance electronic X-16の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Lowrance electronic X-16をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはLowrance electronic X-16の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Lowrance electronic X-16の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Lowrance electronic X-16で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Lowrance electronic X-16を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はLowrance electronic X-16の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Lowrance electronic X-16に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちLowrance electronic X-16デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。