O WNERS MANU AL FOR Oil Lubricated Air Compressor MODEL No MA C700 SPECIFICA TION CHART Model # MAC700 Horsepower 2 SCFM @ 40 PSIG 3.8 SCFM @ 90 PSIG 3.3 Cut-In Pressure 100 PSI Cut-Out Pressure 130 PSI Bore 47 mm S troke 44 mm V oltage -Single Phase 120 Motor RPM 1720 Amperage @ max pressure 12.
Page 2 T ABLE OF CONTENTS SAFETY INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 W arning Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 GLOSSARY . . . . . . . . . . . . . . . . . .
Page 3 IMPORT ANT SAFETY INSTRUCTIONS *SA VE THESE INSTRUCTIONS* WARNING IMPROPER OPERA TION OR MAINTENANCE OF THIS PRODUCT COULD RESUL T IN SERIOUS INJUR Y AND PROPERTY D AMAGE. READ AND UNDERST AND ALL WARNINGS AND OPERA TING INSTRUCTIONS BEFORE USING THIS EQUIPMENT .
Page 4 HAZARD Risk of Air T ank Bursting Risk of Attachments and Accessories Bursting HOW T O PREVENT IT • Follow the equipment manufacturers recommendation and never exceed the maximum allowable pressure rating of attachment s. Never use the compressor to inflate small low- pressure objects such as children’s toys, footballs, basketballs, etc.
Page 5 HAZARD Risk of Electric Shock Risk of Explosion or Fire Risk to Breathing WHA T CAN HAPPEN • Y our air compressor is powered by electricity . Like any other electrically powered device, if it is not used properly , it may cause electrical shock.
Page 6 HAZARD Risk to Breathing (continued) Risk from Compressed Air Risk from Mo ving Par ts Risk of Bur n WHA T CAN HAPPEN solvents, p aint remover , insecticides, weed killers, etc., contain harmful vapors and poisons. • Breathing compressor or sprayed materials vapor can result in serious injury .
Page 7 GLOSSAR Y CFM: Cubic feet per minute. SCFM: S tandard cubic feet per minute; a unit of measure of air delivery . PSIG: Pounds per square inch gauge; a unit of measure of pressure. CUT -IN PRESSURE: While the motor is off, air t ank pressure drops as you continue to use your accessory or air tool.
Page 8 product was shipped directly to you, report any damages to the carrier and arrange for inspection of goods immediately . ST ORAGE Before you store the air compressor , make sure you do the following: 1. Review the “ Maintenance” and “Operating Procedures” sections and perform maintenance as necessary .
Page 9 reaches “cut-out” pressure. PRESSURE SWITCH: The pressure switch automatically start s the motor when the air tank pressure drop s to the factory set “cut-in” pressure. It stops the motor when the air tank pressure reaches the factory set “cut-out” pressure.
Page 10 amount of oil may be present in the pump upon receipt of the air compressor . This is due to factory testing and does not mean the pump contains oil. CAUTION: Multi-Viscosity motor oils, like 10W 30, should not be used in an air compressor . They leave carbon deposits on critical components, thus reducing performance and compressor life.
Page 11 grounding plug. The plug must be used with an outlet that has been installed and grounded in accordance with all local codes and ordinances. The outlet must have the same configuration as the plug. DO NOT USE AN ADAPTER. Inspect the plug and cord before each use.
Page 12 MAINTENANCE W ARNING: UNIT CYCLES AUTOMA TICALL Y WHEN POWER IS ON. WHEN DOING MAINTENANCE, YOU MA Y BE EXPOSED TO VOL T AGE SOURCES, COMPRESSED AIR OR MOVING P ARTS. PERSONAL INJURIES CAN OCCUR. BEFORE PERFORMING ANY MAINTENANCE OR REP AIR, UNPLUG THE COMPRESSOR AND BLEED OFF ALL AIR PRESSURE.
Page 13 Allow oil to drain completely . 2. Replace the oil drain plug (The use of a sealing compound or T eflon tape to avoid leakage is recommended.) 3. Refill with the recommended oil to the proper level. SERVICE INSTRUCTIONS Air Filter - Inspection and Replacement: • Keep the air filter clean at all times.
Page 14 TROUBLESHOO TING GUIDE PERFORMING REP AIRS MA Y EXPOSE VOL T AGE SOURCES, MO VING P ARTS OR COMPRESSED AIR SOURCES. PERSON AL INJURY MA Y OCCUR. PRIOR T O A TTEMPTING ANY REP AIRS, UNPLUG THE COMPRESSOR AND BLEED OFF T ANK AIR PRESSURE. CA USE Defective pressure switch.
Page 15 PROBLEM Pressure reading on the regulated pressure gauge drops when accessory is used. Air leak from safety valve. Compressor is not supplying enough air to operate accessories. Motor will not run. CA USE It is normal for "some" pressure drop to occur .
Page 16 PROBLEM Motor will not run. (con’t) Regulator knob has continuous air leak. Regulator will not shut off at air outlet. CA USE • Check valve is stuck open. • Loose electrical connections. • Possible defective capacitor . • Paint spray on internal motor part s.
Page 17 F ACTOR Y SER VICE CENTERS 1-800-4-MAKIT A RET AIN THIS PORTION FOR YOUR RECORDS ARIZONA 3707 E. Broadway Road, Suite 6 Phoenix, AZ 85040 (602) 437-2850 CALIFORNIA 41850 Christy Street Fremont.
Page 18 WARNING Some dust created by power sanding, sawing, grinding, drilling, and other construction activities contains chemicals known to the S tate of California to cause cancer , birth defects or other reproductive harm.
DA TE PURCHASED MODEL NO. MONTH DA Y YEAR SERIAL NO. ST A TUS SEX INTL. LAST NAME/COMP ANY NAME Married Single M F STREET ADDRESS CITY AREA CODE ST A TE ZIP CODE PHONE AGE: Under 19 20-29 30-39 40-49 50-59 Over 60 BE SURE TO COMPLETE THE CUSTOMER’S PORTION OF THIS FORM AND RET AIN FOR YOUR RECORDS Please return this portion by facsimile or mail.
Makit a U.S.A., Inc. 14930 Northam S treet La Mirada, CA 90638-5753 First Class Postage Required Post Office will not deliver without proper postage.
デバイスMakita MAC700の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Makita MAC700をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはMakita MAC700の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Makita MAC700の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Makita MAC700で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Makita MAC700を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はMakita MAC700の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Makita MAC700に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちMakita MAC700デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。