Copyright © 2005 by Metrologic Instruments, Inc. All rights reserved. No part of this work may be reproduced, transmitted, or stored in any form or by any means without prior written consent, except by reviewer, who may quote brief passages in a review, or provided for in the Copyright Act of 1976.
ii T ABLE O F C ONTENTS Introduction How does the MX009 U SB Cable Operate?...................................................... 1 What is the difference between USB Keyboard Emulation and USB Serial Emulation? .......................................
.
1 I NTRODUCTION Metrologic’s MX009 USB Cable is a device that converts serial RS232 formatted data to either USB Keyboard or USB Serial communication protocol. The MX009 can be used with all Metrologic products equipped with an RS232 interface, as well as all versions of Metrologic PowerLink compatible scanners.
2 I NTRODUCTION • H OW IS THE MX009 CONFIGURED FOR USB KEYBOARD E MULATION ? This guide contains the configuration bar codes necessary to ensure that the scanner communicates properly with the MX009.
3 I NTRODUCTION (C ONT .) • H OW IS THE MX009 CONFIGURED FOR USB S ERIAL E MULATION ? This guide contains the configuration bar codes necessary to ensure that the scanner communicates properly with the MX009. The scanner communicates using RS232 protocol.
4 MX009 USB C ABLE O PTIONS P ART N UMBER C ONNECTOR T YPE S TRAIGHT C OILED USB E ND S CANNER E ND C OMPATIBLE S CANNER M ODELS Discontinued scanner models are shown in grey.
5 MX009 P ART N UMBER D ESIGNATION AND A CCESSORIES P ARTS AND A CCESSORIES Part No. Description MX009 USB Converter Cable MX009-2 xx 7 x USB Keyboard Emulation Cable MX009-2 xx 8 x USB Serial Emulati.
6 C ABLE I NSTALLATION Make sure the AC input requirements of the power supply match the AC outlet. The outlet should be near the equipment and easily accessible.
7 L ABELS Each MX009 has CE, UL and caution information embedded in the back of the case. The following is an example of embedded information. Figure 1. Each MX009 will also have a flag tag attached to the cable with the date of manufacture, model number, and serial number.
8 C ONFIGURING FOR USB K EYBOARD E MULATION (MX009-2 XX 7 X ) PowerLink Compatible Scanners These Metrologic Scanners, used with the MX009 Cable must be reconfigured using the following bar codes before the MX009 can communicate properly with a host system.
9 C ONFIGURING FOR USB K EYBOARD E MULATION (MX009-2 XX 7 X ) 4. Scan the appropriate bar code below to set USB Keyboard Emulation to the country keyboard required ( defaults to USA ). USA ³ 416260 S WITZERLAND ³ 416280 S PAIN ³ 416250 I TALY ³ 416240 G ERMANY ³ 416230 F RANCE ³ 416220 Continued on next page.
10 C ONFIGURING FOR USB K EYBOARD E MULATION (MX009-2 XX 7 X ) U NITED K INGDOM ³ 416210 B ELGIUM ³ 416200 J APANESE ³ 4162100 IBM 4700 F INANCIAL K EYBOARD ³ 416270 S WEDEN /F INLAND ³ 416290 5.
11 C ONFIGURING FOR USB K EYBOARD E MULATION (MX009-2 XX 7 X ) MS6720, MS860, AND T ECH S ERIES These Metrologic Scanners, used with the MX009 Cable must be reconfigured using the following bar codes before the MX009 can communicate properly with a host system.
12 C ONFIGURING FOR USB K EYBOARD E MULATION (MX009-2 XX 7 X ) 4. E NABLE XON/OFF H ANDSHAKING 0 12345 11714 5 5. E NABLE ACK/NAK 0 12345 11713 8 6. C ONFIGURABLE P REFIX #1 0 12345 92000 4 7. C ONTROL V P REFIX 0 12345 00022 5 8. C ONFIGURABLE P REFIX #2 0 12345 92100 1 Continued on next page.
13 C ONFIGURING FOR USB K EYBOARD E MULATION (MX009-2 XX 7 X ) 9. Scan one of the following bar codes to set Keyboard Emulation. B ELGIUM 0 12345 00065 2 U NITED K INGDOM 0 12345 00066 9 F RENCH 0 12345 00067 6 G ERMAN 0 12345 00068 3 I TALIAN 0 12345 00069 0 Continued on next page.
14 C ONFIGURING FOR USB K EYBOARD E MULATION (MX009-2 XX 7 X ) S PANISH 0 12345 00070 6 U NITED S TATES 0 12345 00071 3 S WISS 0 12345 00073 7 S WEDISH /F INNISH 0 12345 00074 4 J APANESE 0 12345 00075 1 Continued on next page.
15 C ONFIGURING FOR USB K EYBOARD E MULATION (MX009-2 XX 7 X ) R ESERVED 0 12345 00076 8 10. E NTER /E XIT C ONFIGURATION M ODE 0 12345 66666 7.
16 C ONFIGURING FOR USB S ERIAL E MULATION (MX009-2 XX 8 X ) PowerLink Compatible Scanners These Metrologic scanners must be reconfigured using the following bar codes before the MX009 can communicate properly with the host system.
17 C ONFIGURING FOR USB S ERIAL E MULATION (MX009-2 XX 8 X ) MS6720, MS860, AND TECH SERIES These Metrologic scanners must be reconfigured using the following bar codes before the MX009 can communicate properly with a host system.
18 C ONFIGURING FOR USB S ERIAL E MULATION (MX009-2 XX 8 X ) 4. E NABLE XON/XOFF H ANDSHAKING 0 12345 11714 5 5. E NABLE ACK/NAK 0 12345 11713 8 6. E NTER /E XIT C ONFIGURATION M ODE 0 12345 66666 7.
19 T ROUBLESHOOTING G UIDE The following guide is for reference purposes only. Contact a Metrologic representative at 1-800-ID-METRO or 1-800-436-3876 to preserve the limited warranty terms on page 22. Test Bar Code Scanning the following bar code will transmit the encoded characters followed by the software number of the MX009.
20 S PECIFICATIONS MX009 USB C ONVERTER C ABLE S PECIFICATIONS M ECHANICAL Dimensions: 80.4 mm (3.2”) L x 32.4 mm (1.3”) W x 18.7 mm (0.7”) H Weight: 160 g (0.35 lb) Termination: 10-pin modular RJ45 Male to USB 10-pin modular RJ45 Female to USB.
21 C ABLE I NFORMATION Scanner Connector End USB Connector End 10-Pin RJ45 Male Type A Locking Type A Pin Function MX009-2MA7x and MX009-2MB7x and 1 Ground MX009-2MA8x or MX009-2MB8x 2 TXD 3 RXD x = C.
22 L IMITED W ARRANTY The MX009 USB converter cables are manufactured by Metrologic at its Blackwood, New Jersey, U.S.A. facility and at its Suzhou, China facility. The MX009 USB converter cables have a two (2) year limited warranty from the date of manufacture.
23 N OTICES TESTED TO COMPLY WITH FCC STANDARDS FOR HOME OR OFFICE USE Notice This device complies with Part 15 of the F CC Rules. Operation is subject to the following two conditions: (1) This device.
24 N OTICES D ECLARATION OF C ONFORMITY According to 47 CFR, Part 2 and 15 for Class B Personal Computers and Peripherals; and/or CPU Boards and Power Supplies used with Class B Personal Computers: We: Metrologic Instruments, Inc.
25 A DDITIONAL B AR C ODES Some Metrologic scanners require alternate configuration steps than the steps found on pages 8 - 18. If your scanner was manufactured before May 2002 or does not accept the standard configuration sequences, you may need to use one of the alternate configuration methods listed on the following pages.
26 A DDITIONAL B AR C ODES 7. *Enable LF Suffix ³ 116612 8. Scan the appropriate bar code below to set USB Keyboard Emulation to the country keyboard required.
27 A DDITIONAL B AR C ODES U NITED S TATES ³ 80360710 R ESERVED ³ 80360720 S WISS ³ 80360730 S WEDISH /F INNISH ³ 80360740 J APANESE ³ 80360750 R ESERVED ³ 80360760 9.
28 A DDITIONAL B AR C ODES Alternate Configuration for USB Serial Emulation (MX009-2xx8x) PowerLink Compatible Scanners 1. E NTER /E XIT C ONFIGURATION M ODE ³ 999999 2. R ECALL D EFAULTS ³ 999998 3. ENABLE RS-232 MODE ³ 415554 4. E NABLE XON/XOFF H ANDSHAKING ³ 115914 5.
29 A DDITIONAL B AR C ODES 6. *E NABLE LF S UFFIX ³ 116612 7. E NTER /E XIT C ONFIGURATION M ODE ³ 999999.
30 C ONTACT I NFORMATION AND O FFICE L OCATIONS C ORPORATE H EADQUARTERS N ORTH A MERICA E UROPEAN , M IDDLE E AST & A FRICAN H EADQUARTERS USA, New Jersey Germany, Munich Metrologic Instruments, Inc. Metrologic Instruments GmbH Tel: 1-800-ID-METRO Fax: 856-228-6673 Tel: 49-89-89019-0 Fax: 49-89-89019-200 Email: info@metrologic.
.
June 2005 Printed in the USA 00 - 02574 D.
デバイスMetrologic Instruments MX009の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Metrologic Instruments MX009をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはMetrologic Instruments MX009の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Metrologic Instruments MX009の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Metrologic Instruments MX009で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Metrologic Instruments MX009を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はMetrologic Instruments MX009の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Metrologic Instruments MX009に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちMetrologic Instruments MX009デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。