MIDAS experiment „alc“ USER MANUAL SR35, 05.07.2006 Data acquisition is running on psw407 (DELL Power Edge 2600). AFS users can logon to pc5145, the local user account is l_musr_alc . Data files are stored locally on psw407 in /home/l_musr_alc/exp/alc and automatically copied to /afs/psi.
start web browser: http://psw407:8080 (PSI only!): Status page (the following screenshots are taken from pc4244…) DO NOT USE ‘Konqueror’ !!!! (only IE, Mozilla, or Firefox).
Start a run for autorun sequence: set autorun_active = 1 (if 0: only single run) there are no ‘scans’ anymore!.
Stop a run Do not interfere the stop ping proced ure – wait until the pages refreshes and shows sta tus ‘stopped’..
Set Magnet change Demand value read Hall probe read NMR probe - field >= 0.0 * - probe is locked * - readout unit is Tesla * - sum of returned errors (returned value < 0.0) * status unit * -1.0 BUS DRIVER I/O TIMEOUT I * -2.0 BUS DRIVER ERROR B * -4.
Set Temperature LTC21: Input: read values Output : set value LTC21_Analog_Set_Point (K).
Set Flow Demand = 3000 for T = 0 – 100 ° C, set Demand = 10000 for cooling down, base temp. ???.
History.
ODB: DO NOT TOUCH! – discuss with Instrument Scientist first Start frontends from term inal by running the command alc_start_midas Shutdown all frontends: alc_mcleanup [l_musr_alc@pc4244 alc]$ alc_mcleanup Midas cleanup procedure for experiment ALC.
mozilla-bin: no process killed killing opera... opera: no process killed Cleaning up shared memory segments for user l_musr_alc ... Cleaning up semaphores for user l_musr_alc .
Separator : vncviewer sepii:0 , pw: exhalle - if only black screen appears use rdesktop sepii , user: halle, pw: exhalle under winXP: Remote Desktop Connec tion (All Programs – Accessories – Communications) for HV = 150 kV: SEP = 746 The beamline setting is nam ed ALC2005_1st_period.
Data written as ASCII file : alc_05_NNNN.dat (run number NNNN) format: 19 header lines followed by data, lines containing 48 coloumns each !File: /home/l_musr_alc/exp/alc/alc_05_0270.
Appendix: Some ODB entries Ip_min is the minimum required beam current on Target E in mA. Measurement is paused when the current is lower. rate_min is the minimum required positron rate in the sum of the backward counters (this makes sure that the run is automatically paused when the beam blocker is closed).
Ip_channel is the channel number (starting at 0, in the above example this is the third channel) of the proton beam current signal, 100 kHz correspond to 1 mA. preset channels is the bitmask for the scaler cha nnels used f or the preset counting register in hex form.
デバイスMidas Consoles SR35の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Midas Consoles SR35をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはMidas Consoles SR35の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Midas Consoles SR35の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Midas Consoles SR35で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Midas Consoles SR35を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はMidas Consoles SR35の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Midas Consoles SR35に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちMidas Consoles SR35デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。