A MIDDLEBY COMP ANY Digital T emperature Controller (KIT P/N 36939) Installation, Programming and T roubleshooting Instructions Middleby Marshall Inc. • 1400 T oastmaster Drive • Elgin, IL 60120 • (847) 741-3300 • F AX (847) 741-4406 Middleby Corporation 24 Hour Service Hotline 1-800-238-8444 © 1997 Middleby Marshall Inc.
INST ALLA TION INSTRUCTIONS This manual provides instructions for conversion: from to Analog T emperature Controller (A), PN 28071-0012 (without high-limit and cool down function)................................ Analog T emperature Controller (A), PN 28071-0018 (with high-limit and cool down function).
Unpacking The Digital T emperature Controller was checked before leaving the factory . Inspect the shipping container carefully for evidence of improper handling during shipment. In case of damage, make an immediate claim to the parts distributor from whom the unit was purchased.
Installing the Digital Controller Step Procedure 1. Insert the Digital T emperature Controller into the same panel slot making sure the face of the controller is upright with the display on top and the push buttons on the bottom. 2.. Identify the two rectangular holes on top and bottom of the control case.
4 } 8 7 6 5 4 L2 L1 9 10 11 12 13 14 15 16 Connect To Connect To [13] [14] [15] [16] [1] [2] Remove From Remove From [5] [6] [L2] [L1] [G] 500 Not used on certain model gas and electric ovens.
5. Check to be sure the oven’s thermocouple is the latest version flange mount style verses the obsolete version. See Figure 4 below . The obsolete thermocouple is not compatible with the latest tem.
6 PS200 Gas Oven, 208-240V , 50/60Hz, 1 Ph, 3W ...............................................................Figure 5 PS200 Gas Oven, 200V , 50/60Hz,1 Ph, 2W (Export Only)................................................Figure 5 PS200 Gas Oven, 208V , 50/60Hz,1 Ph, 2W (Export Only).
7 Figure 7 - Wiring Diagram Showing Electrical Connections (Refer to T able 2) Figure 8 - Wiring Diagram Showing Electrical Connections (Refer to T able 2) Figure 9 - Wiring Diagram Showing Electrical.
Programming After the Digital T emperature Control has been properly installed and wired, it is ready to be programmed for either the standard on/off cycling gas solenoid/electric heating system, or the modulating gas valve system.
Digital Temperature Controller PN 36056 Service instructions Push the lock key and the service key together to reach SP LOK, then use the service key to step through the other functions listed below. Use the arrow keys to change the function settings.
SERVICE KEY: Service use only SET PT: Lit when controller is displaying set point temperature. UP and DOWN arrow keys: Used to change the set point. Press UNLOCK & SET POINT keys simultaneously to unlock set point, UP & DOWN keys will now function for 60 seconds.
Diagnostic Error Messages The controller runs background tests during normal operation. If a problem with the background tests occurs, an error message is shown (flashing) in the Display .
デバイスMiddleby Marshall KIT P/N 36939の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Middleby Marshall KIT P/N 36939をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはMiddleby Marshall KIT P/N 36939の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Middleby Marshall KIT P/N 36939の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Middleby Marshall KIT P/N 36939で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Middleby Marshall KIT P/N 36939を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はMiddleby Marshall KIT P/N 36939の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Middleby Marshall KIT P/N 36939に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちMiddleby Marshall KIT P/N 36939デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。