MTDメーカー500 thru 510の使用説明書/サービス説明書
ページ先へ移動 of 20
Log Splitter Model Series 500 thru 510 PRINTED IN U.S .A. FORM NO . 770-10 509A.f m (7/01) IMPORT ANT : READ SAFETY RULES AND INSTRUCTIONS CAREFULL Y MTD PRODUCTS INC.
2 TABLE OF CONTENTS Cont ent Page Important Safe Ope ration Practice s ........... ............. ................... ............. ........... 3 Assemblin g Your Log Sp litter .............. ............. ............. ................... ............
3 SECTION 1: IMPORTANT SAFE OPERATION PRACTICES WARNING: This symb ol poin ts out impor tant safety instructio ns which, if not follow ed, could endanger the p ersonal safety a nd/or pr operty o f yours elf and others. Read a nd follo w all instruct ions in this man ual before at temptin g to operate this machine.
4 9. To avoid per sonal in jury or pro perty dama ge use extrem e care in han dling gasoli ne. G asolin e is extrem ely flammabl e and the v apors are e xplosive . Seriou s person al inju ry can occu r when gasol ine is spille d on yours elf or your cl othes which can ig nite.
5 8. For yo ur safety, rep lace all da maged or worn pa rts imme diately wi th origina l equipmen t manufact urer ’ s (O.E.M.) parts only. “ Use of parts which do not meet the origi nal equipm ent specif ications may lead to im proper pe rformance and co mpromise sa fety! ” 9.
6 Figure 1 Attaching The Tongue (See Figure 2) • With the lo g spli tter still sta nding upr ight, remove two hex bo lts, lock washers, and he x nuts from the end of the ton gue assemb ly. • Align th e holes in the tongu e with the holes in the tank and sec ure with hard ware just remo ved.
7 Figure 5 • Fill th e reservoi r tank w ith Dexron III a utomatic transmiss ion fluid or 10W AW hy draulic flu id. • Check fl uid level usi ng the dipsti ck. See Figur e 6. • Do not overfill and replac e vented d ipstick s ecurely. The dipstick should be tig hten unti l the top of the threads are flush with the to p of the pipe.
8 NOTE: Certain e ngines may also be equippe d with an on/off sw itch. • Discon nect spar k plug wire and ground agai nst the engine t o prevent unint ended s tarting. Figure 7 SECTION 4: OPERATING YOUR LOG SPLITTER WARNING: Read, understand, and follow all instructions and warnings on th e machine and in t his manual before operating.
9 Always: • Use clea n fluid and ch eck fluid level regul arly. • Use Dexron III Automatic Transm ission Flu id or 10W AW hy draulic flui d. • Use a filte r (clean or rep lace regular ly) • Use a brea ther cap on flui d reservoi r. • Make cer tain pump i s mounted and aligned properly .
10 Tran sporti ng Th e Log Spl itte r • Lower the be am to its hor izontal po sition. Ma ke certain the beam is locked sec urely wit h the horizontal beam lock . • Remove the spring clip and c levis pin from j ack stand. Sup port the tongu e and pivot the jack stand up against the tongue.
11 Drain the fl uid and flush the r eservoir tank and hoses with kero sene whe never any repai r work is per formed on the tank, hy draulic pum p or valve. Cont aminants i n the fluid wil l damage the hy draulic c ompone nts. NOTE: The flushing the rese rvoir tank is recommen ded to be p erformed by an autho rized s ervice d ealer.
12 Storing Y our Log Split ter • Clean the un it thorough ly. • Wipe equ ipment with an oiled rag to prev ent rust. • Refer to eng ine manual for correct engine storage instruc tions. • Store un it in a clean, dry area. Do not st ore next to cor rosive mat erial s such as fertiliz er.
13 SECTION 8: TROUBLESHOOTING NOTE: For r epairs b eyond th e mi nor adjus tments l isted a bove, cont act you r near est auth orized s ervice dealer. Problem Cau se Rem edy Engine fails to s tart 1. Spark plug wi re disc onnected. 2. Fuel tank emp ty or stale fuel .
14 HYDRAULIC TROUBLESHOO TING Problem Cau se Rem edy Cylin der rod will not move 1. Broke n drive shaft. 2. Shippin g plugs left in hydraul ic hose s. 3. Set scr ews in coup ling not adju sted proper ly. 4. Loose sh aft coupl ing. 5. Gear se ction s damaged.
15 Notes.
16 Model Series 500 thru 510 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 10 22 23 24 25 23 26 27 28 29 26 27 28 29 30 30 32 33 18 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 23 51 52 .
17 Model Series 500 thru 510 Ref. No. P ar t No. P art Descri ption 1. 718-0773 Hydr aulic C ylinder 2. 727-0634 Hydr aulic T ube 3. 710-1018 He x Cap Scre w 1/2-20 x 2.75 4. 737-0192 90 Degr ee Solid Adapter 5. 718-0481 Control V alv e 6. 737-0153 Return Elbow 7.
18.
19.
MANUF A CTURER ’ S LIMITED W ARRANTY The l imit ed warr anty se t for th be low is gi ven by MTD PRODUCTS INC ( “ MTD ” ) with respe ct to ne w mercha ndise purchase d and used in the Uni ted Stat es, i ts pos sessio ns and ter ritories.
デバイスMTD 500 thru 510の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
MTD 500 thru 510をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはMTD 500 thru 510の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。MTD 500 thru 510の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。MTD 500 thru 510で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
MTD 500 thru 510を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はMTD 500 thru 510の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、MTD 500 thru 510に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちMTD 500 thru 510デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。