(R evised 2010 -11- 15 ) p age 1 of 30 102RAS Industrial Remote Access Server User Manual & Installation Guide.
(R evised 2010 -11- 15 ) p age 2 of 30 Table of Contents Industrial Remote Access Server Installation Guide .....................................................................................3 General Safety Warnings ................................
(R evised 2010 -11- 15 ) p age 3 of 30 Industrial Remote Access Server Installation Guide 102RAS The N-TRON 102RAS provides connectivity to an industrial LAN for telecommuters or mobile users, or to re motely in stalled equipment, via an integrated V.
(R evised 2010 -11- 15 ) p age 4 of 30 Copyright, © N-Tron Corp., 2008 820 S. University Blvd., Suite 4E Mobile, AL 36609 USA All rights reserved. Reproduction, adaptation, or translation without prior written permission from N-Tron Corp. is prohibited, except as allowed under copyright laws.
(R evised 2010 -11- 15 ) p age 5 of 30 Environmental Safety WARNING: Disconnect the power and allow to cool 5 minutes before touching . Electrical Safety WARNING: Disconnect the power cable before removing any modules, or any enclosure panel. WARNING: Do not operate the unit with the cover removed.
(R evised 2010 -11- 15 ) p age 6 of 30 5. Class I , Div 2 Installations require th at power connections must be current limited at the power source with an in-line fuse rated at 0.5A. 6. Class I, Div 2 inst allations require that all devices connected to this product must be UL listed for the area in which it is installed.
(R evised 2010 -11- 15 ) p age 7 of 30 DIN Rail Mounting Install the unit on a standard 35mm DIN rail. Recess the unit to allow at least 3 ” of horizontal clearance for cable bend radius. To mount the unit t o the 35mm DIN rail, place top edge of the brackets on the back of the unit against the DIN rail at a 45° upward angle.
(R evised 2010 -11- 15 ) p age 8 of 30 Front Panel From Top to Bottom: Green LED lights when Power is supplied to the module RJ -45 Port Auto sensing 10/100 Base-TX Connection RJ -11 Port Phone line connection TR Transmit Read y CD Carrier Detect TX Transmit RX Receive Note: The RJ 45 data port has two LED’s locate d at the side of the connector.
(R evised 2010 -11- 15 ) p age 9 of 30 Applying Power (Top View) Remove Supplied #6 Phillips head grounding screw from top of unit. Connect ground wire with lug (not supplied) a nd r e-install the grounding screw securely.
(R evised 2010 -11- 15 ) p age 10 of 30 N-TRON SWITCH GROUNDING TECHNIQUES The grounding philosoph y of any cont rol s ystem is an inte gral part of the design. N -Tron swi tches are designed to be grounded, but the user has been given the flexibili ty to float the switch when required.
(R evised 2010 -11- 15 ) p age 11 of 30 RJ45 CONNECTOR CRIMP SPECIFICATIONS Please reference the illustration below for your Cat5 cable specifications:.
(R evised 2010 -11- 15 ) p age 12 of 30 Ov erview of Features Compact Remote Access Solution The 102RAS includes one integrated V .92/56K modem, housed in a compact, industrial chassis which provides V.92/56K download speeds and 48K upload speeds when connecting with V.
(R evised 2010 -11- 15 ) p age 13 of 30 Troubleshooting 1. Make sure the (Power LED) is ON. 2. Make sure you are supp lying sufficient c urrent. Note: The Inrush current will exceed the steady state current by ~ 2X. 3. Verify that Link LED’s are ON for connected ports.
(R evised 2010 -11- 15 ) p age 14 of 30 Regulatory Statements 47 CFR Part 15 Regulation This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) th.
(R evised 2010 -11- 15 ) p age 15 of 30 9. If your h ome or office has specially wired a larm equipm ent connected to the telephone line, ensure the installation of this equipment does not disable y our alarm equipment. If you have questions about what will disable alarm equipment, consult y our telephone compan y or a qualified installer.
(R evised 2010 -11- 15 ) p age 16 of 30 restricted to lower bit rates when connected to some PSTN implementations. Telecom will accept no responsibility should difficulties arise in such circumstances. 2. Immediately disconnect this equipment should it become physicall y damaged, and arrange for its disposal or repair.
(R evised 2010 -11- 15 ) p age 17 of 30 China Approved 20650004500320 China NALTE Approved 10-6066-060989 Cyprus Approved CE Czech Republic Approved CE Denmark Approved CE Estonia Approved CE Finland .
(R evised 2010 -11- 15 ) p age 18 of 30 Software Configuration Web Manage m en t Enter the switch’s IP address in an y web browser and login to the web mana gement feature o f the 102RAS.
(R evised 2010 -11- 15 ) p age 19 of 30 Web Manage m en t - Home When the administrator first logs onto the 102RAS, the default home page is displ aye d.
(R evised 2010 -11- 15 ) p age 20 of 30 Web Manage m en t – Menu Structu re Home Shows information about the manufacturer and the 102RAS, along with support Website and E-Mail addresses.
(R evised 2010 -11- 15 ) p age 21 of 30 Administration – IP Configuration The IP Configuration part of the Administration page lists the following information about the 102RAS : IP Address Subnet Ma.
(R evised 2010 -11- 15 ) p age 22 of 30 Administration – Time Configuratio n The Time Configuration part of the Administration page lists the following information about the 102RAS : Time Server Request Interval Time Zone Date Format Time Format Fr om here y ou can set the time configuration used for time stamping on the 102RAS.
(R evised 2010 -11- 15 ) p age 23 of 30 From here, the Administrator’s Name, User ID and Password can be changed. Also, L ocal users may be added by filling out a new row and selecting the add button.
(R evised 2010 -11- 15 ) p age 24 of 30 Current Status - System This page shows the Current System Status of the 102RAS and shows the following values: Current Time Up Time Pending Messages Email Status Email To Subject Time Server Status Current Time - Indicates the present time of day.
(R evised 2010 -11- 15 ) p age 25 of 30 Current Status – POTS modem 1 This page shows the Current Status of the POTS Modem embedded in the 102RAS. State Connect Time Elapsed Time State - I ndicates .
(R evised 2010 -11- 15 ) p age 26 of 30 Note: The following modem sharing options are availab le, but N-Tron does not provid e techni cal support for using third party sof tware with the 102RAS ( N-Tron also does not provide any software for this use).
(R evised 2010 -11- 15 ) p age 27 of 30 If you are setting up the 102RAS to use Radius authentication, then: 1) Enter the IP address of th e primary RADIUS Server in the RADIUS Server Address 1 field. 2) Enter the port number (usuall y port 1812) for the RADIUS Server in the top Port field.
(R evised 2010 -11- 15 ) p age 28 of 30 KEY SPECIFICATIONS Physical Height: 3.40" (8.64cm) Width: 1.50" (3.81 cm) Depth: 3.60" (9.14 cm) Including DIN-Rail Mount: 4.
(R evised 2010 -11- 15 ) p age 29 of 30 REGULATORY APPROVALS SAFETY : Suitable for use in Class I, Division 2, G roups A, B, C and D Hazardous Locations, or Nonhazardous Locations only.
(R evised 2010 -11- 15 ) p age 30 of 30 N-TRON Li mited Warranty N-TRON, Corp. warrants to t he end user that thi s hardware product w ill be free from defects in workmanship and materials, under normal use and service, for the applicab le warranty pe riod from the date of purcha se from N -TRON or its autho rized reseller.
デバイスN-Tron 102RASの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
N-Tron 102RASをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはN-Tron 102RASの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。N-Tron 102RASの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。N-Tron 102RASで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
N-Tron 102RASを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はN-Tron 102RASの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、N-Tron 102RASに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちN-Tron 102RASデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。