1 W415-0360 / 11.05.02 INSTALLATION AND OPERATION INSTRUCTIONS FOR HI-TECH LISTED SOLID FUEL BURNING STOVES AND INSERTS FREE ST ANDING MODELS EP A 1 100, 1 100L, 1 100C, 1400, 1400L & 1900 INSERT MODELS EPI 1 101, 1401 INSTALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER.
2 W415-0360 / 1 1.05.02 NAPOLEON wood fireplaces are manufactured under the strict Standard of the World Recognized ISO 9001 : 2000 Quality Assurance Certificate. NAPOLEON products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work.
3 W415-0360 / 11.05.02 PG 2-4 INTRODUCTION Warranty General Information Care of Plated & Enamelled Parts Care of Glass 5-6 INST ALLA TION Installing the Legs Alcove Installation Stove Installation.
4 W415-0360 / 11.05.02 INTRODUCTION GENERAL INFORMATION Except for their different depths, models 1100, 1400, 1900 and the fireplace inserts 1101 and 1401 are iden- tical and use the same burning principles. They were specifically designed over many months of research to meet the 1990 U.
5 W415-0360 / 11.05.02 STOVE INSTALLATION If the stove is to be installed on a combustible floor, it must be placed on a approved non-com- bustible hearth pad, that extends 8" (200mm) beyond the stove sides and back, and 18" (455mm) to the front.
6 W415-0360 / 11.05.02 DO NOT USE ANY MAKESHIFT MATERIALS DURING INSTALLATION. 1. Move the stove into position with the flue centered, midpoint between two joists to prevent having to cut them.
7 W415-0360 / 11.05.02 OUTSIDE AIR Connection from the stove's air intake to the outside is mandatory in mobile homes only, either through a hole in the wall to line up with the knockout in the pedestal back, or through a hole in the floor to line up with the hole in the pedestal base.
8 W415-0360 / 11.05.02 In the United States, continued: If a continuous liner is not installed, a "direct flue con- nection" must be made. The direct flue connection re- quires a non-combust.
9 W415-0360 / 11.05.02 1101 FAN SERVICE OR REPLACEMENT 1. Turn off all electrical power to the insert. Remove the glass door and set aside in a safe place. 2. Remove the top right side bricks from inside the firebox, 4-#7's and 2- #2's. Then remove the rest of the side and back bricks from the right side of the 1101 insert.
10 W415-0360 / 11.05.02 MODEL 1401/1400L - FIGURE 20 MODEL 1101/1100L - FIGURE 18 12 12 10 10 10 10 11 11 11 11 MODEL 1400 - FIGURE 19 MODEL 1100/1100C - FIGURE 17 BRICK RETAINER DETAIL - TYPICAL MODEL 1900 - FIGURE 21 AREA CIRCLED ON EACH FIGURE INDICATES THE BRICK RETAINER DETAIL SIZES #1.
11 W415-0360 / 11.05.02 BRICK and BAFFLE INSTALLATION With stove and chimney installation completed, move the bricks into place by working as illustrated for your unit on page 10. 1. Install two or three courses of brick on both sides of the unit. Install two courses on the back wall.
12 W415-0360 / 11.05.02 You can now add larger pieces of wood and operate the stove normally. Once the stove/insert is entirely hot, it will burn very efficiently with little smoke from the chim- ney. There will be a bed of orange coals in the firebox and secondary flames flickering just below the top fire- brick.
13 W415-0360 / 11.05.02 DO NOT OVERFIRE THE STOVE! Overfiring can occur by: a) burning large amounts of smaller wood pieces such as furniture scraps, skids or treated wood; b) vigorously burning large loads of wood with the draft control on "HIGH" (fully open) for long periods of time (one or two hours).
14 W415-0360 / 11.05.02 WOOD PILE MAINTENANCE Burn only dry, clean unpainted wood that has been seasoned. It produces more heat and less soot or creosote. Freshly cut wood contains about 50% moisture while after proper seasoning only about 20% of the water remains.
15 W415-0360 / 11.05.02 ORDERING PROCEDURES Contact your dealer or the factory for questions concerning prices and policies on replacement parts. Normally all parts can be ordered through your Napoleon dealer or distributor. When ordering replacement parts always give the following information: 1.
16 W415-0360 / 11.05.02 58 57 40 53 50 51 52 48 24 29 49 1 43 33 31 28 32 15 17 19 35 34 35 37 36 38 44 55 1 39.
デバイスNapoleon EPA 1100の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Napoleon EPA 1100をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはNapoleon EPA 1100の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Napoleon EPA 1100の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Napoleon EPA 1100で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Napoleon EPA 1100を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はNapoleon EPA 1100の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Napoleon EPA 1100に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちNapoleon EPA 1100デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。