NewAirメーカー8625の使用説明書/サービス説明書
ページ先へ移動 of 12
1 Application The Robertshaw 8625 is a multi-stage thermostat designed to control 24 V AC heat pump systems. Features • Large back lit display . • Four preprogrammed E NERGY S TA R ® setpoints for each day of the week. • Adjustable 1 st stage temperature differential: 1.
IMPORT ANT SAFETY INFORMA TION WARNING: • Always turn off power at main fuse or circuit breaker panel before installing, removing, cleaning, or servicing thermostat. • Read all the information in this manual before installing this thermostat. • DO NOT CONNECT TO 120 V AC.
IMPORT ANT SAFETY INFORMA TION WARNING: In heat pump applications, do not connect anything to the W1 terminal. When switched to HP mode, W1 is connected internally to Y1 on the thermostat. Connect AUX heat to the W2/E terminal. 1. T urn off power to heating and cooling system.
6. Mark placement of mounting holes (see Figure 3). Set base aside. 7. Drill the marked holes using a 3/16” (5mm) drill bit. NOTE: Enclosed plastic anchors do not require a drilled hole for drywall. 8. T ap plastic anchors into the wall. 9. Align base with plastic anchors and feed wires through opening (see Figure 3).
Wiring Diagrams The following is just a sample of the most common types of HV AC systems. Refer to your system’ s installation manual for wiring information.
6 T o T est Thermostat WARNING: DO NOT SHORT (JUMPER) ACROSS TERMINALS OF GAS V AL VE OR SYSTEM CONTROL TO TEST OPERA TION. THIS WILL DAMAGE THE THERMOST A T AND VOID YOUR W ARRANTY . CAUTION: DO NOT SWITCH SYSTEM TO COOL IF THE TEMPERA TURE IS BELOW 50°F (10°C).
Programming Guide SETTING TIME OF DA Y AND DA Y OF WEEK 1. Press SELECT until the cursor is over SET CLOCK. Press SET . The HOURS segment will be blinking. Use the or button to adjust the time. NOTE: The AM or PM indicator will change as the HOURS display rolls through a 24 hour cycle.
6. After pressing SET for the 4th event, the day of the week along the top will switch to SA T SUN and AM1 will be displayed. Repeat steps 2-4 to program the weekend settings. 7. With the weekend settings programmed, place the HEA T -OFF-COOL switch in the COOL position.
6. Press SET . The display will switch to the differential setting for 2 nd stage heating and cooling. 7. The display will read diF2 . Press the or button to adjust the differential up or down. 8. Press SET . The display will switch to the differential delay .
Another way to select a temporary hold is: 1. Press SELECT until the cursor is over TEMP HOLD. Press SET . The temperature will be blinking. Use the or button to change the temperature. 2. Press SET . T o cancel a temporary hold, press SELECT until the cursor is above RUN/SET PROG.
T roubleshooting Symptom Remedy Thermostat does not turn Check wiring. on system. (See Installing Item 8625 Thermostat ) Thermostat turns on and off too Increase temperature differential. frequently . (See Programming Guide ) System fan does not operate Move the Electric/Gas switch to properly .
12 ©2004 Climate Controls Americas 110-1101 Climate Controls Americas 191 E. North Avenue Carol Stream, Illinois 60188 United States of America TWO-YEAR LIMITED W ARRANTY Climate Controls Americas wa.
デバイスNewAir 8625の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
NewAir 8625をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはNewAir 8625の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。NewAir 8625の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。NewAir 8625で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
NewAir 8625を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はNewAir 8625の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、NewAir 8625に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちNewAir 8625デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。