2531550-B NH Series Outdoor ELECTRODE STEAM HUMIDIFIER Out door Model Inst allation Manual TM.
2008-10-01 PROPRIETARY NOTICE This document and the info rmation disclosed herein ar e propriet ary data of W alter Meier . Neithe r this document nor the information cont ained herein shal l be repro.
2008-10-01 TABLE OF CONTENTS Subject Page 10-00 INT RODUCTI ON 1. PREINSTALLATIO N . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 A. ABOUT THIS GUIDE . . . . . .
2008-10-01 LIST OF FIGURES Figure Page 10-00 I NTRODUCT ION Figure 1. Humidifier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Figure 2. Distributor Box Contents .
2008-10-01 THIS PAGE INTENTIONALLY LEFT BLANK.
10-00 Page 1 2008-10-01 10-00 INTRODUCTION.
10-00 Page 2 2008-10-01 1. PRE-INSTALLATION A. ABOUT THIS GUIDE (1) This guide is intended as a supplement for the NH Series Installation Gui de. The NH Series Installation guide is included with all NH Series humidifier s and contains information on installation, operation, and maintenance that applies to both indoor and outdoor models.
10-00 Page 3 2008-10-01 (a) For equipment received if an ASD, BSD, CSD distributor(s) is ordered refer to Figure 2. (b) For equipment received if a SAM-e distributor is ordered refer to Figure 3. (c) For equipment received if a RMBP is ordered refer to Figure 4.
10-00 Page 4 2008-10-01 Figure 1. Humidifier Figure 2. Distributor Box Contents Figure 3. SAM-e Distributor Box Figure 4. Blower Pack Box Contents.
10-00 Page 5 2008-10-01 3. PRE-INSTALLATION A. EQUIPMENT VERIFICATION (1) Ensure that available voltage and phase corresponds with humidifier voltage and phase as indicated on humidifier’s specification label.
10-00 Page 6 2008-10-01 THIS PAGE ITENTIONALLY LEFT BLANK.
10-10 Page 7 2008-10-01 10-10 INSTALLATION PROCEDURES.
10-10 Page 8 2008-10-01 1. HUMIDIFIER INSTALLATION A. LOCATION AND MOUNTING (1) NH Outdoor Series humidifiers are UL listed for outdoor installation and come complete with internal cooling for the electronics. An internal heater is sta ndard and ensures the enclosure remains at proper operating temperatures.
10-10 Page 9 2008-10-01 C. CURB MOUNTING (1) The integral base of the NH Outdoor models is designed to mount on a curb. The curb must be built to structurally support the entire weight of the humidifier when in operation. Required curb dimensions are given in Figure 1.
10-10 Page 10 2008-10-01 (c) Wall mounting bracket provided should be securely attached horizontally with open edge upwards, using 5/16” x 3” (minimum) flat head screws. (See Figure 4). (d) Using proper lifting techniques, lift the humidifier onto the brackets to m ount it.
10-10 Page 11 2008-10-01 RIG H T FRON T LEFT TO P FR O N T V IEW BOT T OM V I E W KNOC KOUT FOR PO WER L IN E AN D HOL E S F OR CONT R O L WIRI N G KNO CKOUT FOR OP T IONA L WATE R I N L E T BAC K V I EW ST EAM L IN E CON NECT ION 1.
10-10 Page 12 2008-10-01 DRAIN L INES PUNCHOUT S PROVIDED FOR POWER WIRING TO AND FRO M BREAKER INSULATED AND HE AT-TRACED WATER SUPPLY ( BY OTHERS) CAN ALSO BE ROUTED THROUGH PIPE-CHASE A ND PROVIDED.
10-10 Page 13 2008-10-01 Figure 4. Typical Wall Mount Installation.
10-10 Page 14 2008-10-01 E. ELECTRICAL INSTALLATION (1) Only qualified personnel should install electrical wiring. All wir ing must be in accordance with national and local codes. (2) Power and control wiring is to be routed into the humidifier through the pipe chase in the base of the unit.
10-10 Page 15 2008-10-01 (5) Additionally the following points should be considered: (a) Each unit is supplied with a ½” NPT male connection to the fill valve. Refer to the NH series indoor installation guide for allowa ble pressures and fill rates.
10-10 Page 16 2008-10-01 Figure 5. Normally Open / Normally Closed Valve Arran geme nt.
10-10 Page 17 2008-10-01 Figure 6. 3-Way Valve Arrangement.
10-10 Page 18 2008-10-01 G. DRAIN LINE (1) NH Series Outdoor units require and external drain line to provide for draining from the unit. (2) ALL OUTDOOR PIPING SHOUL D BE PROPERLY INSUL ATED AND HEAT TRACED TO PREVENT FREEZIN G.
10-10 Page 19 2008-10-01 guide (Steam Distributor Installation Guide Form #XX-231 and SAM-e Short Absorption Manifold Form #XX-249). 2. IMPORTANT INFORMATION A. GENERAL CAUTION Y OUR HUMIDIFIER OPERATES ON HIGH VOLTAGE AND CURRENTS, W HICH CAN CAUSE SERIOUS IN JURY OR DEATH.
10-10 Page 20 2008-10-01 WARNING IT IS ESSENTIAL THAT THE FANS AND HEA TERS BE INSPECTED PERIODICALLY TO ENSURE THA T THEY CAN SPIN FR EELY AND HAVE NOT BECOME CLOGGED W ITH DIRT, POLLEN, OR BY A NIMALS. THIS IS ESPECIALLY TRUE OF THE EXTE RNAL CASE FAN A ND FAN SHROUD.
10-10 Page 21 2008-10-01 available to signal remotely that he humidifier requires service. If the NORTEC OnLine option was ordered, cylinder change not ices will be delivered via email. (2) Please refer to the NH Series Indoor Installation guide for further details on replacing cylinders.
10-10 Page 22 2008-10-01 (c) Once the unit has reached an appropriate temperature it will resume normal operation. 3. OPERATION AND ADDITIONAL MAINTENANCE A. OPERATION (1) NH Outdoor series humidifiers are operated in the same manner as their indoor counterparts.
10-10 Page 23 2008-10-01 Table 1. Weather Design Data JA NUA RY Temperature JA NUA RY Relative Humidity (% RH) JULY Temperature JULY Relative Humidity (% RH) State/Province City Dry Bulb °F Dry Bulb °C 7:30 A.M . 1:30 P.M. 7:30 P.M. Dry Bulb °F Dry Bulb °C 7:30 A.
10-10 Page 24 2008-10-01 Missouri Kansas City -10 -23 78 64 66 100 38 76 48 47 St. Louis 0 -10 77 65 68 95 35 73 50 55 Montana Billings -25 -32 67 73 60 90 32 65 40 33 Butte -20 -29 76 70 71 95 35 82 .
10-10 Page 25 2008-10-01 Wyoming Cheyenne -15 -26 59 48 55 95 35 73 36 40 A lberta Calgary -29 -34 71 87 31 34 Edmonton -29 -34 75 86 30 42 Grande Prairie -43 -42 80 84 29 38 Lethbridge -32 -36 66 91 .
10-10 Page 26 2008-10-01 Sherbrooke -18 -28 87 31 58 Trois Rivieres -18 -28 88 31 58 Saskatchewan Prince Albert -41 -41 77 88 31 Regina -34 -37 81 92 33 Saskatoon -34 -37 76 90 32 Swift Current -29 -3.
10-20 Page 27 2008-10-01 10-20 TECHNICAL.
10-20 Page 28 2008-10-01 Figure 1. NHRS Outdoor Exploded Vi e w.
10-20 Page 29 2008-10-01 Figure 2. NHTC Outdoor Exploded Vie w.
10-20 Page 30 2008-10-01 THIS PAGE INTENTIONALLY LEFT BLANK.
10-30 Page 31 2008-10-01 10-30 WIRING DIAGRAMS.
10-30 Page 32 2008-10-01 Figure 1. Wiring Diagram NHTC Outdoor.
10-30 Page 33 2008-10-01 Figure 2. Wiring Diagram NHRS Outdoor (Single).
10-30 Page 34 2008-10-01 Figure 3. Wiring diagram NHRS Outdoor (Double).
THIS PAGE INTENTIONALLY LEFT BLANK.
WARRANTY (1) Walter Meier Inc. and/or Walter Meier Ltd. (herein after collectively referred to as THE COMPANY), warrant for a period of two years afte r installation or 30 months from manufacturer’s.
Cylinder Replacement Da te (MM/DD/YYYY) INST ALLA TION DA TE (MM/DD/YYYY) MODEL # SERIAL # CYLINDER # U.S.A. W alter Meier (Climate USA) Inc. 826 Proctor Avenue Ogdensburg, NY 13669 TEL: 1-866-NORTEC-1 EMAIL: northamerica.climate@waltermeier .com WEBSITE: www .
デバイスNortec Industries NH Seriesの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Nortec Industries NH Seriesをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはNortec Industries NH Seriesの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Nortec Industries NH Seriesの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Nortec Industries NH Seriesで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Nortec Industries NH Seriesを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はNortec Industries NH Seriesの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Nortec Industries NH Seriesに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちNortec Industries NH Seriesデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。