OS1592 Infrared Fiber Optic Thermometer/T ransmitter MADE IN omega.com e-mail: info@omega.com For latest product manuals: omegamanual.info Shop online at U ser ’ s Guide.
Servicing Nor th America: U.S.A.: One Omega Drive, P.O. Box 4047 ISO 9001 Certified Stamford, CT 06907-0047 TEL: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com Canada: 976 Bergar Laval (Quebec) H7L 5A1, Canada TEL: (514) 856-6928 FAX: (514) 856-6886 e-mail: info@omega.
W ARRANTY / DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 25 months from date of purchase. OMEGA ’ s W ARRANTY adds an additional one (1) month grace period to the normal two (2) year product warranty to cover handling and shipping time.
T ABLE OF CONTENTS SECTION ..................................................................P AGE Section 1 Introduction ........................................................................ 1 Section 2 Installation ...............................
T ABLE OF FIGURES FIGURE ..................................................................P AGE 1 OS1592 Main Unit ............................................................................ 3 2 Power Supply and Analog Output Connections ...........
INTRODUCTION The new OS1592 series Infrared Fiber Optic Thermometer/T ransmitter provides non-contact temperatur e measurement for industrial applications.
The following describes the ordering information: The unit provides two separate analog outputs. The first is 1mV/Deg (Standard). The second analog output to be specified as follows : - * , where, - m.
2.2 – Electrical Connection Attach the optical assembly to the optical adapter located on the side of the housing. Refer to Fig. 1 for the overall appearance of the unit. Open the cover of the aluminum housing. Slide your cable through the metal feed thru and connect the wir es to the 9 position terminal block (J101) as shown in Fig.
OPERA TION T able 1 shows all the display modes of the model OS1592, as well as all the functions of the membrane keypad. Fig 3 shows the V isual Functional flow chart of the display . Table 1 - Functional Flow Chart Figure 3 - Visual Functional Flow Chart OS1592 Infrared Fiber Optic Thermometer/T ransmitter 3 4 DISPLA Y MODE: Press to.
The Emissivity setting as well as the temperature Engineering unit (°F or °C) are stored in the non-volatile memor y . Removing the main power will not erase or change these settings. 3.1 - Changing the T emperature from °F to °C (or vice versa) Press the key to go to either the MAX , MIN, or DIF display mode.
0-5VDC: Measured T emp = [ ( V oltage Output ) x (T2 - T1) ] + T1 5 0-10VDC: Measured T emp = [ ( V oltage Output ) x (T2 - T1) ] + T1 10 Where, T1 is the minimum temperature range T2 is the maximum temperature range 3.
Figure 5 - Optical Lens Assembly (L1) .25" @ 8" FOV Figure 6 - Optical Lens Assembly (L1) .19" @ 20" FOV Figure 7 - Optical Lens Assembly (L1) .076" @ 6" FOV Figure 8 - Ceramic Tip Assembly (L2) OS1592 Infrared Fiber Optic Thermometer/Transmitter 3 7 111 (4.
Figure 9 - Polymer Bolt Assembly (L3) with 90° Angle Air Purge Fitting Figure 10 - Optical Head, Mounting Bracket OS1592-MB Figure 11 - Air Purge Collar OS1592 Infrared Fiber Optic Thermometer/Transmitter 3 8 FIBER 72 (2.84) 53 ± 1.5 (2.10 ± 0.06) 12.
SPECIFICA TIONS T emperature Range R1 260 to 538°C (500 to 1000°F) R2 538 to 1093°C (1000 to 2000°F) R3 1093 to 2482°C (2000 to 4500°F) Accuracy at 22°C (72 °F) 1% of Rdg. ambient temperature and at Emissivity of 0.95 or greater Repeatability 0.
Display Backlit LCD dual display Keypad switch 4 position, tactile feed back membrane Electrical Isolation Between Input supply and Analog outputs, 1000 V AC Calculated T emperature Maximum (MAX), Min.
OS1592 Infrared Fiber Optic Thermometer/T ransmitter 5 11 MAINTENANCE Routine maintenance is not requir ed except for periodic re-calibration, occasional inspection of the input and output ends of the fiber assembly for cleanliness, and a check for broken fibers if damage is suspected.
OS1592 Infrared Fiber Optic Thermometer/Transmitter Addendum 12 Safety W arnings and IEC Symbols This device is marked with international safety and hazardous symbols in accordance with IEC1010.
M3672/0905 Where Do I Find Ever ything I Need for Pr ocess Measurement and Contr ol? OM EGA…Of Course! Shop online at omega.com TEMPERA TURE 䡺 ⻬ Thermocouple, RTD & Thermistor Probes, Connec.
デバイスOmega Engineering OS1592の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Omega Engineering OS1592をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはOmega Engineering OS1592の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Omega Engineering OS1592の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Omega Engineering OS1592で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Omega Engineering OS1592を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はOmega Engineering OS1592の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Omega Engineering OS1592に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちOmega Engineering OS1592デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。