ESP AÑOL ENGLISH 3 series A utomatic W rist Blood Pr essure Monitor Model BP629 INSTRUCTION MANU AL.
2 TABLE OF CONTENTS Before using the Monitor Introduction ......................................................................................................... 3 Safety Information ..................................................................
3 INTRODUCTION Thank you for purchasing the OMRON ® BP629 IntelliSense ® Automatic W rist Blood Pressure Monitor . The monitor is compact and easy-to-use at home, at work, and during travel. Perfect for people who frequently monitor their own blood pressure.
4 SAFETY INFORMA TION T o assure the corr ect use of the product, basic safety measur es should always be followed including the warnings and cautions listed in this instruction manual. SAFETY SYMBOLS USED IN THIS INSTRUCTION MANUAL WARNING Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury .
5 SAFETY INFORMA TION Do not use a cellular phone near the device. It may result in an operational failure. Use only Omron authorized parts and accessories. Parts and accessories not approved for use with the device may damage the unit. Useonly1.
6 BEFORE T AKING A MEASUREMENT T o ensure a reliable reading follow these recommendations: 1. A void eating, drinking alcohol, smoking, exercising, and bathing for 30 minutes before taking a measurement. Rest for at least 15 minutes before taking the measurement.
7 KNOW Y OUR UNIT Main Unit: Components: 2 “ AAA ” Alkaline Batteries Instruction Manual Quick Start Guide Date/Time Setting ( ) button Display Wrist cuff Memory (MEM) button ST ART/STOP butt on B.
8 UNIT DISPLA Y Memory symbol A verage v alue symbol Irregular heartbeat symbol Pulse display Movement error symbol Battery low symbol Date/Time display Heartbeat symbol (Flashes during measurement) S.
9 DISPLA Y SYMBOLS IRREGULAR HEAR TBEA T SYMBOL ( ) When the monitor detects an irregular rhythm two or more times during the measurement, the Irregular Heartbeat Symbol ( ) will appear on the display with the measurement values.
10 This is a general guideline because blood pressure depends on age and morbidity . A lower home blood pressure goal may be recommended for certain patients, including diabetic patients, pregnant women, and patients with renal failure. WARNING Contact your physicianfor specicinformation aboutyour blood pressure.
11 BA T TERY INST ALLA TION CAUTION Useonly1.5V“AAA”alkalinebatterieswiththisdevice. 1. Press the hook on the bottom of the battery cover and lift the cover off in the direction of the arrow .
12 BATTERY REPLACEMENT Low Battery Indicator When the Low Battery Indicator appears on the display , turn the monitor off and remove all the batteries.
13 SET TING THE DA TE AND TIME Setthemonitortothecurrentdateandtimebeforetakingameasurementfortherst time. If the date and time has not been set, the measurement values are stored without any date or time information.
14 3. SETTING THE MONTH Press the Date/T ime Setting button ( ) to advance by increments of one month. Press the Date/T ime Setting button ( ) to set the current month. Thedayashesonthedisplay . 4. SETTING THE DA Y Press the Date/T ime Setting button ( ) to advance by increments of one day .
15 CAUTION Read all of the information in the instruction manual and any other literature in the box before operating the unit. CAUTION This device is intended for use in measuring blood pressure and pulse rate in the adult population. Do not use this device on infants or persons who cannot express their intentions.
16 5. Fold the remaining part of the wrist cuff back out of the way . APPL YING THE CUFF ON THE RIGHT WRIST When taking a measurement using the right wrist position the cuff as shown in the illustration.
17 1. Sitcomfortablyinachairwithyourfeetatontheoor . 2. Hold your arm across your chest at heart level. Holdyourelbowrmlytoavoidbodymovement. Sit still and do not talk or move during the measurement.
18 T AKING A MEASUREMENT Thecuffstartstoinateautomatically . Asthecuffinates,themonitorautomaticallydeterminesyouridealinationlevel. Thismonitordetectsyourbloodpressureandpulserateduringination.
19 USING THE MEMOR Y FUNCTION Every time you complete a measurement the monitor stores the blood pressure and pulse rate in the memory . The monitor automatically stores up to 60 sets of measurement values (blood pressure and pulse rate). When 60 sets of measurement values are stored, the oldest record is deleted to save the most recent values.
20 USING THE MEMOR Y FUNCTION NOTES: • PresstheMEMbuttonrepeatedlytodisplaythenextvalues. •PressandholdtheMEMbuttontodisplaythevaluesfaster . The date and time are alternately displayed with the measurement values.
21 CARE AND MAINTENANCE T o keep your digital blood pressur e monitor in the best condition and protect the unit fr om damage, follow the directions listed below: Do not forcefully bend the cuf f. Do not fold tightly . Clean the monitor with a soft dry cloth.
22 ERROR INDICA TORS SYMBOL CAUSE CORRECTION Monitor could not detect pulse wave. T ake another measurement and remain still until the measurement is complete. Cuffunder -inated. Cuff not applied correctly . Remove the monitor from your wrist. Read“T akingaMeasurement”.
23 TROUBLESHOO TING TIPS PROBLEM CAUSES AND SOLUTIONS No power . No display appears on the unit. Replace both batteries with new ones at the same time. Check the battery installation for proper placement of the battery polarities. Measurement values appear too high or too low .
24 FC C ST A TEMENT Note: POTENTIAL FOR RADIO/TELEVISION INTERFERENCE (for U.S.A. only) This product has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
25 Y our BP629 IntelliSense ® Automatic W rist Blood Pressure Monitor , excluding the wrist cuff and batteries, is warranted to be free from defects in materials and workmanship appearing within 2 years from the date of purchase, when used in accordance with the instructions provided with the monitor .
26 SPECIFICA TIONS Model: BP629 (HEM-6200-Z) Display: LCD Digital Display Measurement Range: Pressure: 0 to 299 mmHg, Pulse: 40 to 180/min. Accuracy/Calibration: Pressure: ±3mmHg or 2% of reading Pul.
Omron Healthcar e, Inc. 1200 Lakeside Drive Bannockburn, IL 60015 www .omronhealthcare.com Copyright © 2010 Omron Healthcare, Inc. Made in China 5329416-7A.
デバイスOmron Healthcare BP629の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Omron Healthcare BP629をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはOmron Healthcare BP629の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Omron Healthcare BP629の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Omron Healthcare BP629で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Omron Healthcare BP629を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はOmron Healthcare BP629の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Omron Healthcare BP629に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちOmron Healthcare BP629デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。