U SER G UIDE I NDUSTRIAL D ATA C OMMUNICA TIONS It is essential that all instructions contained in the User Guide are followed precisely to ensure proper operation of equipment.
DA T A-LINC GROUP PN 161-xxxxx-001A Product User Guide FCC Information Appropriate FCC info.
DA T A- L I N C GROUP p LCM100 User’s Guide LCM100 Line Carrier Modem Introduction In the line carrier system, the hot line supplies current to connected loads and is a lso used as a carrier for data communication between modules.
DA T A- L I N C GROUP p LCM100 User’s Guide Note: If a three-to-two-wire adapter is used to connect to a two-wire AC outlet, the ground lead of the adapter must be connected to earth ground to complete the ground system. An open ground connection may cause a communications defect and/or shock hazard.
DA T A- L I N C GROUP p LCM100 User’s Guide Communication Failure C a r r i e r D e t e c t O f f RS-232C Input Modulator/Oscillator Failure Failure P o w e r Indicator Off Receiver Signal Modulator.
DA T A- L I N C GROUP p LCM100 User’s Guide LCM100 Technical Specifications Power requirements 120 volts at +/- 10%, 50- 60 Hz, 4.5 watts. Power is on when module(s) are con nected Data Rate Up to 9.
DA T A- L I N C GROUP p LCM100 User’s Guide Appendix A RS-232 Connector Pin Assignments Both modules of the LCM100 have female DB-25 connectors which can be directly connected to DTE and DCE equipment. All output levels are a minimum of +6 volts when active and a maximum of –6 volts when inactive, measured in a 3k ohm load.
DA T A- L I N C GROUP p LCM100 User’s Guide Connector J2 (Female) Please note that male pin numbering is a mirror image of the female connector depicted below: 13 12 11 10 9 8 7 6 5 4 3 2 1 25 24 23 22 21 20 19 18 17 16 15 14 Figure 3: DB-25P J2 Connector Pins J2 Pin Description 9-19 Pins 9-19 are unused, open.
DA T A- L I N C GROUP p LCM100 User’s Guide Appendix B Line Conditioning In some industrial installations, power lines must be conditioned to prevent the FSK signal from being shunted by distributed capacitance possibly associated with other loads conne cted to the line.
DA T A- L I N C GROUP p LCM100 User’s Guide Appendix C System Block Diagram Data T erminal Equipment RS-232C Interface DB-25P Connec tors w/Cab le Pin 2 LCM 100-2 Data Communicatio ns Equipment RS-2.
デバイスOmron LCM100の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Omron LCM100をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはOmron LCM100の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Omron LCM100の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Omron LCM100で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Omron LCM100を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はOmron LCM100の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Omron LCM100に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちOmron LCM100デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。