Omronメーカーne-c801の使用説明書/サービス説明書
ページ先へ移動 of 30
Compressor Nebuliser Mode l NE-C801 • Instruction Manual • Mode d’em ploi • Gebrauchsanweisu ng • Manuale di ist ruzioni • Manual de instruccion es • Gebruiksaanwijzin g • РУ К ОВОДСТВО ПО ЭКСПЛУ А Т АЦ ИИ TM TM EN FR DE IT ES IM-NE-C 801S- E-03-1 1/2011 948739 9-6C NL AR RU NE-C8 01S-E_B _M02_10 0827.
2 Contents Befo re using the de vice Introduction ............ ................... ............. ............. ................... ............. .......... 3 Intended use ................. ............. ............. ................... ............. .
3 EN Introduction Thank you for purchas ing the OMRON COMP AIR. This pr oduct was develope d in conj unction with resp iratory th erapis ts for the succe ssful treatmen t of asthma, chr onic bronchi tis, aller gies and othe r respirato ry disord ers. T he compr essor for ces air to the neb uliser k it.
4 Import ant safety instructions Read all the inform ation in the instruct ion manual and any other literat ure in clude d in the box before using the device.
5 Important safety instr uctions EN • Use o nly original OMRON A C adapter . U se of u nsupport ed AC adap ter may damage th e dev ice. • Do not operate t he dev ice with a dam aged p ower cord o r plug. • Keep the pow er cord awa y from h eated sur faces.
6 Importan t safety instructio ns • Do not block th e slit be tween th e cap and the inh alation ai r inlet . • Do not use a microwa ve oven o r hair dr yer to d ry the ne bulisin g parts. • Approv ed for h uman use o nly . • If the device is used continu ously , the serv ice life of the dev ice may be shor tened.
7 EN 1. Know your unit Air T ube (PVC, 100cm) Air T ube Connector Nebuliser Kit Holder Air Filter Cover *A ir f ilt er ins id e Power Connector Compress or (Main Unit) Cap Inhalation Air Inlet Inhalat.
8 1. Know your unit Accessories Compressor Nebuliser Model NE-C801 • Instruction Manual • Mode d’emploi • Gebrauchsanweisung • Manuale di istruzioni • Manual de instrucciones • Gebruiksa.
9 EN 2. Guide to using t he device Prep aring the Nebuliser for Use - Secti on 3 (p age 10-13) W arning: Clean and disinfec t the neb uliser ki t, mouthp iece and n osepiec e or mask s before using th.
10 3. Prep aring the nebuliser f or use W arning: Clean and disinfect the nebuliser kit, mouthpiece and nosepiece or masks before using them for the fi rst time after purchase, i f the device has not been used for a long period of time, or if more than one person uses the same device.
11 3. Preparing the nebuliser fo r use EN 3.2 Adding medication and ass embling the part s 1. Remo ve the mou thpiece a nd cap from the nebu lise r kit. 2. Remo ve the inh alation to p from the medicati on tan k. 1) Rotate the inh alatio n top anti-c lockwis e.
12 3. Preparin g the nebulis er for use 6. Attach the desired inhalati on attachment, as desc ribed be low . Attaching the mouthpiece 1) Attach the c ap to the i nhalat ion air inl et. 2) Attach the m outhpiece to the inh alatio n top. Attaching the nosepiece 1) Attach the c ap to the i nhalat ion air inl et.
13 3. Preparing the nebuliser fo r use EN 7. Attach the air tube. 1) T wist th e air tube pl ug sligh tly and p ush it firm ly into th e air tube connec tor on the compres sor . 2) T wist th e air tube pl ug sligh tly and p ush it firm ly into th e air tube connec tor on the medication tank.
14 4. T aking medication 1. Hold the nebul iser kit a s indic ated on the right. Caution: Do not t ilt the ne buliser kit at an angle of greater than 4 5° in all direction. Medication ma y flow into the mouth. 2. Press the powe r switc h to the on ( ) posi tion.
15 4. Tak ing me dica tion EN 3. Inhale m edic ation accor ding to y our doc tor ’s and/or he alth c are advi ser ’s instruct ions. Prepare the inhal ation attachme nt accordi ng to Sec tion 3 (page 12). Using the mouthpiece Inser t the mouthp iece into your mo uth and inhale the med ication breathing no rmally .
16 4. Takin g medication 4. When trea tment is com plete, turn th e power off. Check tha t there is no conden satio n or mois ture in the air tu be and unplug the device from the power outlet . W arning: Condensation may occur in the ai r tube. Do not store the air tub e while it cont a ins condensation or moisture.
17 EN 5. Cleaning and daily disinfecting 5.1 Cleani ng Follow ing the cleanin g instru ction s after each use will preven t any re mainin g medicat ion in t he tank from dr ying, re sulting i n the dev ice not ne bulisin g effectively and als o for preve nting infe ctions.
18 5. Clea ning and daily disinfectin g 7. If the co mpressor is dirty , wipe it clea n with a soft cloth moi stened with w ater or mild detergent. Caution: The compressor is not waterproof . 8. If the ou tside of the air tube is dirty , wipe it clean wi th a soft cloth moi stened with wate r or mild detergent.
19 5. Cle aning and daily disinfecting EN Handling t he V apori ser Head The vapor iser head i s an imp ortant part that is u sed to va porise medication. Be sure to obser ve the fol lowing pr ecautio ns when handling it. Caut ion: • Alway s wash the vapori ser head a f t er eac h use.
20 5. Clea ning and daily disinfectin g Use the table below as a guideli ne to selec t a metho d for disi nfecting. Part s Model Materials Mouthpie ce C28-3P-E PP Nosepi ece C28-7-E PP Nebuliser Kit S.
21 5. Cle aning and daily disinfecting EN O: app licab le ×: not applica ble * an exam ple of comme rcially availabl e disin fectant. Boiling Alcohol Sodi um hypoc hlo rit e Quatern ary ammonium Chlorhexidine Amphoteric surfact ant Disinfectin g etha nol Milton* (0.
22 6. Maintenance and storage T o keep your device in the best con dition and prote ct the device f rom damag e foll ow thes e dir ections : Caution: • Do not leav e the devi ce una ttended with infan ts or persons who canno t express thei r consent .
23 EN 7. Changing the air fi lter If the air filter has changed colou r , or has been used on aver age for m ore than 60 days , replace i t with a new one. 1. Pull the ai r filt er cov er of f the com pre ssor . 2. Chan ge the air fi lter . 3. Put the air filt er cover back in pl ace.
24 8. T roubleshooting Check th e followin g if your unit sh ould fa il during o perat ion. Y ou can also refer t o the pages of this m anual f or compl ete in structi ons. Note: If the suggest ed remedy doe s not solve the pr oblem, do not try to repair the devic e - no parts of the u nit ar e user ser viceab le.
25 EN 9. T echnic al dat a Notes: • Subjec t to techn ical mod ification witho ut prior not ice. • This OMRON prod uct is p roduced under the strict quality system of OMR ON HEAL THCARE Co., Ltd., Japan. • The device may not wo rk if the temperat ure and v oltage condi tions ar e different to those define d in the s pecific ations.
26 9. Te chnica l da ta T ech nical data for the OMRON NE -C801 Comp ressor with the OMRON V .V .T . (Virtua l V alve T echnology) Nebuliser kit: Result of cascade imp actor measure m ents for particle s ize** * Measured by OMRON HEAL THCA RE Co., Ltd.
27 9. Tech nical da ta EN Important information regar ding Electro Magnetic Compatibility (EMC) With the i ncreas ed num ber of ele ctronic devic es su ch as PC ’s and mobi le (ce llul ar) teleph ones, me dical devi ces in us e may be susceptib le to electro magnetic in terference fr om other devices .
28 9. Te chnica l da ta Correct Disposa l of This Product (Waste Elect rical & Ele ctronic Equipm ent) This ma rking sho wn on th e product or its literatur e, in dicates that it sho uld not be disposed of, with other hou sehold wa stes at the end o f its worki ng life.
29 EN 10. Optional p art s and accessori es O m r o n V. V. T . N e b u l i s e r K i t N-01 Set Model: C80 1S-NSET3-E Order No.: 951 5573-6 Air T ube (PVC, 100c m) Model: C801S-A TBP-E Order N o.: 951 5575-2 Mout hpiece Model: C28-3P-E Order N o.: 9956 273-5 Air T ube ( Sil i cone, 100 cm) Model: C28-6-E Order N o.
30 10. Opti onal parts and a ccessories Made in Ch ina Manufacturer OMRON HEAL THCARE Co., Lt d. 53, Kunot subo, T era do-cho, M uko, Kyoto , 617-0002 JAP AN EU-represent a tive OMRON HEAL THCARE EURO PE B.V . Scorpius 33, 2132 L R Hoofddorp, TH E NETHERLAND S www .
デバイスOmron ne-c801の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Omron ne-c801をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはOmron ne-c801の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Omron ne-c801の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Omron ne-c801で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Omron ne-c801を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はOmron ne-c801の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Omron ne-c801に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちOmron ne-c801デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。