IPS-RDPE-2 Remote Data Port INSTALLATION/OPERATION C2473M-D (10/06).
.
C2473M-D (10/06) 3 Contents Important Safe ty Instruct ions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Description .
4 C2473M-D (10/06) Important Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed al l warnings. 4. Follow all instructions. 5. Install ation should b e done only b y qualified personnel a nd conform to all local co des.
C2473M-D (10/06) 5 Description Pelco’ s IPS-RDPE-2 data port box is an on-site s ervice tool de signed fo r Spectra ® , Esprit ® , and ExSite ™ Series positioning systems. The data port box gives on-site access for setu p and testing of the position ing system.
6 C2473M-D (10/06) Mounting Instructions W ALL MOUNTING 1. Open the lid of the IP S-RDPE-2 box. Install two 3/4-inch (1.9 1 cm) conduit fittings (not supp lied). Close the lid of the IPS- RDPE-2 box. 2. Determine the mo unting location fo r the IPS-RDPE-2.
C2473M-D (10/06) 7 POLE MOUNTING 1. Install the P A402 mount adapter . Ref er to the i nstructions su pplied with the adapter . 2. Open the lid of the IP S-RDPE-2 box. Install two 3/4-inch (1.9 1 cm) conduit fittings (not supp lied). Close the lid of the IPS- RDPE-2 box.
8 C2473M-D (10/06) Cable/Wire Requirements and Connector Locations Refer to Figure 3 for a layou t of the data port box connector s. It is important to connect all fou r communication wir es from the IPS-RDPE -2 to the Spectra dome system or ExSite system.
C2473M-D (10/06) 9 Wiring Diagrams The IPS-RDPE-2 is designed t o work in b oth coaxial c able and UTP video tran smission systems. Installation configura tions includ e the following: • Coaxitron C.
10 C2473M-D (10/06) Figure 5. Coaxitron Controller with UTP Video – Passive Receiver Only NOTES: • Input po wer for the IPS-RDPE-2 is 24 VAC only . The max imum wire gau ge allowed fo r power inpu t and outp ut is 12 AWG. • The maximu m wire gauge allowed for U TP is 16 AWG.
C2473M-D (10/06) 11 Figure 6. RS-422 (D or P Protocol) Controller with Coax Video – Point-to-Point Configuration NOTES: • Input po wer for the IPS-RDPE-2 is 24 VAC only . The max imum wire gau ge allowed fo r power inpu t and outp ut is 12 AWG. • The maximum wire gaug e allowed for two-wire communication is 16 A WG.
12 C2473M-D (10/06) Figure 7. RS-422 (D or P Protocol) Controller with Coax Video – Home Run Configuration NOTES: • Input po wer for the IPS-RDPE-2 is 24 VAC only . The max imum wire gau ge allowed fo r power inpu t and outp ut is 12 AWG. • The maximum wire gaug e allowed for two-wire communication is 16 A WG.
C2473M-D (10/06) 13 Figure 8. RS-422 (D or P Protocol) Controller with Coax Video – Daisy-Chain Configuration NOTES: • Input po wer for the IPS-RDPE-2 is 24 VAC only . The max imum wire gau ge allowed fo r power inpu t and outp ut is 12 AWG. • The maximum wire gaug e allowed for two-wire communication is 16 A WG.
14 C2473M-D (10/06) Figure 9. RS-422 (D or P Protocol) Controller with UTP Video – Point-to-Point Configuration NOTES: • Input po wer for the IPS-RDPE-2 is 24 VAC only . The max imum wire gau ge allowed fo r power inpu t and outp ut is 12 AWG. • The maximu m wire gauge allowed for U TP is 16 AWG.
C2473M-D (10/06) 15 Figure 10. RS-422 (D or P Protocol) Controller wit h UTP Video – Home Run Configuration NOTES: • Input po wer for the IPS-RDPE-2 is 24 VAC only . The max imum wire gau ge allowed fo r power inpu t and outp ut is 12 AWG. • The maximu m wire gauge allowed for U TP is 16 AWG.
16 C2473M-D (10/06) Figure 11. RS-422 (D or P Protocol) Controller wit h UTP Vid eo – Daisy-Chain Configuration NOTES: • Input po wer for the IPS-RDPE-2 is 24 VAC only . The max imum wire gau ge allowed fo r power inpu t and outp ut is 12 AWG. • The maximu m wire gauge allowed for U TP is 16 AWG.
C2473M-D (10/06) 17 Operation T o view video, control pan /tilt/zoom, or upload rev ised operat ing software a nd language files to a p ositioning s ystem, do the f ollowing: 1. Open the do or of the IPS- RDPE-2. Open ing the door will automatica lly disconnect the controller at t he head-end a nd trigger an audible alert at the IPS-RD PE-2 site .
18 C2473M-D (10/06) Specifications ELECTRICAL Input V oltage 24 V AC Power Consumpt ion 1 V A Does not inc lude power required fo r position ing system MECHANICAL Construction Aluminum Finish Gray polyester powder coat Cable Entry T wo hole plugs will accommodate 3/4-inch (1.
The materials used in the manufacture of this docume nt and it s components are compliant to the requirements of Directive 2002/9 5/EC. This equipment contains elec trical or electronic components tha.
W orldwide Headquarters 3500 Pelco W ay Clovis, California 93612 USA USA & Canada T el: 800/289-9100 Fax: 800/289-9150 International T el: 1-559/292-1981 Fax: 1-559/348-1120 www .
デバイスPelco ips-rdpe-2の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Pelco ips-rdpe-2をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはPelco ips-rdpe-2の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Pelco ips-rdpe-2の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Pelco ips-rdpe-2で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Pelco ips-rdpe-2を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はPelco ips-rdpe-2の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Pelco ips-rdpe-2に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちPelco ips-rdpe-2デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。