PentairメーカーIC20, IC40の使用説明書/サービス説明書
ページ先へ移動 of 32
IMPOR T ANT SAFETY INSTR UCTIONS READ AND FOLLO W ALL INSTR UCTIONS SA VE THESE INSTR UCTIONS Installation and User’ s Guide IntelliChlor ™ Electr onic Chlorine Generator (Model IC20, IC40) Patent.
© 2006 P entair W ater P ool and Spa, Inc. All rights reser ved This document is subject to change without notice 1620 Hawkins A v e., Sanf ord, NC 27330 • (919) 566-8000 10951 W est Los Angeles Av e.
i IntelliChlor Installation and User ’ s Guide Contents IntelliChlor Overview .................................................................................................................................... 1 Features ...........................
ii IntelliChlor Installation and User ’ s Guide IMPORTANT SAFETY PRECAUTIONS Impor tant Notice: Attention Installer: This manual contains impor tant information about the installation, operation and saf e use of this product. This information should be given to the owner and/or operator of this equipment.
iii IntelliChlor Installation and User ’ s Guide IMPORTANT SAFETY PRECAUTIONS CA UTION - Use of chemicals other than those recommended ma y be hazardous. Follo w the Chemical Manuf acturer’ s Instructions. CA UTION - T o reduce the risk of electr ic shock, install IntelliChlor cell at least 5 f eet from the inside wall of the pool.
iv IntelliChlor Installation and User ’ s Guide Installation Steps Summary The recommended IntelliChlor installation steps are: Revie w Chemistr y Y ou Need to Know (pa g e 11) : Review this important information. Review Optim um P ool W ater Conditions (page 12) : Review NSPI standards information.
1 IntelliChlor Installation and User ’ s Guide IntelliChlor Overview The IntelliChlor™ salt chlorinator uses a process known as electrolysis to produce Sodium Hypochlorite (liquid chlorine) from a low concentration of salt added to the pool water .
2 IntelliChlor Installation and User ’ s Guide Electrolytic Cell Controller The electrolytic cell controller includes a control panel with buttons and LED indicators to fully control and produce chlorine. The cell controller measures the water temperature and salt level to optimally produce chlorine.
3 IntelliChlor Installation and User ’ s Guide IntelliChlor P ower Center The Power Center converts AC electrical current to a low voltage DC current which is required by the cell to perform the electrolysis.
4 IntelliChlor Installation and User ’ s Guide Loop Plumbing Diagram The IntelliChlor will operate in water flow rates from 15 gallons per minute up to 1 10 gallons per minute (the limit of 2” plumbing). For flow rates over 80 gallons per minute, it is recommend that you use a bypass loop (shown below) for best chlorine production.
5 IntelliChlor Installation and User ’ s Guide Section 1 IntelliChlor Control P anel This section describes the IntelliChlor control panel status LEDs and the More, Less and Boost/On/Off control buttons. Salt Level Status LEDs The salt level is checked daily and is displayed on this section of the unit.
6 IntelliChlor Installation and User ’ s Guide Operator Control P anel (continued) Sanitizer Output LED Indicators The five LED indicators display as a bar graph to show in 20% increments, the amount of time the chlorine is produced per hour . In BOOST mode, these LEDs scroll in a pattern.
7 IntelliChlor Installation and User ’ s Guide Section 2 Operating IntelliChlor This section describes the start up procedure and operating instructions for IntelliChlor . Initial Star t up P eriod For the first 30 days of cell operation, the self-cleaning cycle will be set to two hours.
8 IntelliChlor Installation and User ’ s Guide Startup Procedure (Super Chlorination) Shocking (Super Chlorination) is recommended before pool startup. Start out with clean pool water from the beginning. IntelliChlor will build up a sufficient level of chlorine for sanitation in several hours.
9 IntelliChlor Installation and User ’ s Guide Section 3 User Maintenance This section describes how to maintain the IntelliChlor chlorination system. Daily service. None is needed. W eekly service . 1. Chlorine T est: T est pool water chlorine level with a reliable test kit.
10 IntelliChlor Installation and User ’ s Guide Monthly Service (Continued) 3. T otal Alkalinity T est: T est pool water for total alkalinity with a test kit. Adjust according to your pool professional’ s recommendations. 80-120 PPM APSP Standard.
11 IntelliChlor Installation and User ’ s Guide WARNING Working with muriatic acid can be dangerous. When cleaning elements always wear rubber gloves and eye protection. Always add acid to water, do not add water to acid. Always work in a well-ventilated area.
12 IntelliChlor Installation and User ’ s Guide Optimum P ool W ater Conditions In accordance with the Association of Pool and Spa Professionals (APSP) standards, it is recommended that the followin.
13 IntelliChlor Installation and User ’ s Guide Chlorine T esting It is recommended that chlorine test samples be taken from two places. Compare the samples. A higher level should be found at the pool return line. The higher level at the pool return line indicates IntelliChlor is producing chlorine.
14 IntelliChlor Installation and User ’ s Guide How to Ad d Salt to the Pool CA UTION: Do not operate IntelliChlor with newly poured pool plaster; salt damage can occur . W ait at least 1 MONTH to allow new pool plaster to cure before operating IntelliChlor .
15 IntelliChlor Installation and User ’ s Guide T able 2. Approximate Pounds (kg) of Salt Needed to Maintain 3,000 PPM T able 3. Approximate Amount of Chlorine S tabilizer (Cyanuric Acid) Needed to Obtain 75 PPM NOTE: Add 1.25 lb (0.57 kg) Chlorine S tabilizer to the pool every time 50 lb (22.
16 IntelliChlor Installation and User ’ s Guide P ool W ater Preparation Determining P ool Size (m3 of W ater in Y our P ool) • Rectangular Pools: Length x width (meters) x average depth x 1000 .
17 IntelliChlor Installation and User ’ s Guide Section 4 Installation This section describes how to install the IntelliChlor electrolytic cell assembly into the pool plumbing system. Also, included are connection instructions for IntelliT ouch and EasyT ouch systems.
18 IntelliChlor Installation and User ’ s Guide Installing the Cell Assembly Install the IntelliChlor cell assembly no closer than three (3) feet from the heater outlet, if used.
19 IntelliChlor Installation and User ’ s Guide Connecting the P ower Center to an IntelliT ouch or EasyT ouch System T o operate IntelliChlor with the IntelliT ouch or EasyT ouch system, connect a four wire cable from the IntelliChlor Power Center to the IntelliT ouch or EasyT ouch load center .
20 IntelliChlor Installation and User ’ s Guide Connecting IntelliChlor to an IntelliT ouch System T o connect the four wire cable communication from the IntelliChlor Power Center (see page 19) to t.
21 IntelliChlor Installation and User ’ s Guide Connecting IntelliChlor to an EasyT ouch System T o connect the four wire cable from the IntelliChlor Power Center (see page 19) to the motherboard located in the EasyT ouch load center: W ARNING Switch OFF main system pow er to the load center before making any connections .
22 IntelliChlor Installation and User ’ s Guide Section 5 T r oubleshooting Use the following troubleshooting information to resolve possible problems with the IntelliChlor system. Note: Switch power off to unit before to attempting service or repair .
23 IntelliChlor Installation and User ’ s Guide m e l b o r Pe s u a C e l b i s s o Pn o i t c A e v i t c e r r o C s i t h g i l t l a s D D A d e R . n o g n i e b s i e n i r o l h c o N . t l a s s d e e n r e t a w l o o P . d e c u d o r p d n a , 4 1 , 3 1 s e g a p n o d e b i r c s e d s a t l a s d d A .
24 IntelliChlor Installation and User ’ s Guide System Specifications - 110 V A C and 220 V A C Wiring Circuit Protection: T wo-pole 20 AMP device at the electrical panel. IntelliChlor Model IC20 Input: 90-130 V AC, 50/60 Hz, 220 W atts (2 AMP) or 220-240 V AC, 50/60 Hz, 220 W atts (1 AMP).
LIMITED WARRANTY P entair Water P ool and Spa, Inc. ("P entair W ater") manufactures its products with the highest standards of wo r kmanship, using the best materials av ailable through state of the ar t process.
P/N 520589 - Rev D.
デバイスPentair IC20, IC40の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Pentair IC20, IC40をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはPentair IC20, IC40の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Pentair IC20, IC40の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Pentair IC20, IC40で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Pentair IC20, IC40を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はPentair IC20, IC40の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Pentair IC20, IC40に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちPentair IC20, IC40デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。