Instruction book 2920 1521 00 1 Atlas Copco Stationary Air Compressors Instruction book SF1 - SF2 - SF4 Skid -Tank-mounted SF6 - SF8 Twin SF6 - SF8 - SF11 - SF15 Multi Copyright 2003, Atlas Copco Airpower n. v, Antwerp, Belgium. Any unauthorized use or copying of the contents or any part thereof is prohibited.
Instruction book 2920 1521 00 2 This instruction book de scribes how to handle the machine s to ensure safe operation, optimum efficiency and long service life. Read this book before putting th e machine into operation to ensure correct handli ng, operation and proper maintenance from the beginning.
Instruction book 2920 1521 00 3 1 LEADING P ARTICULARS.......................................................................................................... ......... 5 1.1 General de scription .....................................................
Instruction book 2920 1521 00 4 7.16 SF6-15 Multi 145 psi 60 Hz 1) ............................................................................................ ...... 40 8 REGULATOR FUNCTION S FOR SF MULTI .............................................
Instruction book 2920 1521 00 5 1 LEADING PARTICULARS 1.1 General description SF1 up to SF15 are stationary, oil-free comp ressors driven by an electri c motor. 1.1.1 Compressor variants SF Skid (Fig. 1.2) The components of the compressor are housed in a bodywork with removable front/top panel.
Instruction book 2920 1521 00 6 1 Control panel 2 Air outlet valve Fig. 1.2 SF4 Skid 1 Control panel 2 Air outlet valve 1.3 SF4 Tank-mounted.
Instruction book 2920 1521 00 7 1 Control panels 2 Air outlet valve Fig. 1.4 SF Twin 1 Elektronikon regulator 2 Electric cabinet 3 Air outlet valve 4 Dryer (on Full-Featu re) 5 Compressor modules S3 Emergency stop button Fig.
Instruction book 2920 1521 00 8 1 Elektronikon regulator 2 Electric cabinet 3 Air outlet valve 4 Dryer (on Full-Featu re) 5 Compressor modules 6 Safety valve (ASME) S3 Emergency stop button Fig. 1.6 SF15FF Multi 1 Air filter 2 Compressor element 3 Air cooler 4 Belts 5 Safety valve 6 Drive motor 7 Safety valve Fig.
Instruction book 2920 1521 00 9 1 Air filter 2 Drive motor 3 Compressor element 4 Compressed air outlet 5 Safety valve (CE) Fig. 1.8 Details of a compressor modul e on SF Multi 1.2 Air flow Air is drawn through the air filter into the comp re ssor modules and is com pressed.
Instruction book 2920 1521 00 10 1.4 Regulating system on SF Skid - Tank-mounted - Twin The air net pressure is kept within limits by a pres su re switch mounted in the cabi net below the control panel (Fig. 1.10). The swi tch is connected to the air outlet and electrically conn ected in the circuit of the drive motor.
Instruction book 2920 1521 00 11 1.5 Regulating system on SF Multi SF Multi are provided with an Elektronikon® re gulator (Fig. 1.11) to control the compressor. The following is a short description of the main functions of the reg ulator. Consult section 8 for a detailed description of all functions.
Instruction book 2920 1521 00 12 Fig. 1.11 Elektronikon regulator on SF Multi 1.5.5 Control panel (Fig. 1.11) To control the compressor and to read and m odify progra mmable para meters, the regulator is p rovided with a control panel including: Ref Designation Function 1 Start button Push button to start the compressor.
Instruction book 2920 1521 00 13 1.5.6 Display – keys Compressor Outlet 7.0 bar Compressor Running ↓ Menu - - - - F1 F2 F3 Fig. 1.12 Typical example of a display Operating condition of a compressor module The symbols shown above key F3 indicate the opera ting condition of each control module, see also se ction 8.
Instruction book 2920 1521 00 14 Designation Function Menu Starting from the main screen, to have access to submenus Menu Starting from a submenu, to return to a previous menu Modify To modify program.
Instruction book 2920 1521 00 15 1.6 Electric cabinet on SF Multi F1/8 Fuses K11 Auxiliary contactor, dryer K21/24 Contactors Q21/24 Circuit breakers T1/2 Transformers 1X0 Terminal strip, mains suppl y 1X2 Terminal strip, dryer 1X3/6 Terminal strips Fig.
Instruction book 2920 1521 00 16 1.7 Air dryer on SF Full-Feature (Fig. 1.15) Compressed air circuit Wet compressed air enters heat exchan ger (13) and is co oled by the outgoing, cold, dried ai r.
Instruction book 2920 1521 00 17 2 INSTALLATION 2.1 Dimension drawings (Figs. 2.1 up to 2.5) 9820 4052 00/1 55100D (1) (2) (3) (4) (5) (6) (7) (8) Fig.
Instruction book 2920 1521 00 18 9820 4054 00/1 55102D (1) (2) (2) (1) (3) (4) (5) (6) (7) (8) Fig. 2.3 Dimension drawing, SF 6-8 Twin Text on Figs.2.1/2.3 1 Motor cooling air outlet 5 Electrical supply 2 Element cooling outlet 6 Type 3 Cooling air inlet 7 Pressure 4 Compressed air outlet 8 Mass, approx.
Instruction book 2920 1521 00 19 (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (11) (8) (9) (12) (13) (14) (15) 9820 4027 00 55098D Fig. 2.4 Dimension drawing, SF 6-8 Multi.
Instruction book 2920 1521 00 20 9820 4026 00 55099D (1) (16) (2) (3) (4) (5) (6) (7) (8) (9) (10) (11) (8) (9) (12) (13) (14) (15) Fig. 2.5 Dimension drawing, SF 11-15 Multi.
Instruction book 2920 1521 00 21 Text on Figs. 2.4/2.5 (1) Electric cable (2) Manual drain (3) Automatic drain (4) Compressor cooling air ou tlet (5) Bodywork ventilation (6) Aftercooler and dryer coo.
Instruction book 2920 1521 00 22 2.2 Installation proposal (Fig. 2.6) 9820 3960 00 55097D (3) (1) (2) Fig. 2.6 Installation proposal, SF Multi Text on Figs.
Instruction book 2920 1521 00 23 1 Install the compressor on a level floor, in a c ool but frost-free room which is well -ventilated. The air should be clean. 2 Position of compressed air outlet valve. 3 The maximum total pipe length can be calculated as follows: L = (dP x d 5 x P) / (450 x Qc 1.
Instruction book 2920 1521 00 24 2.3 Electrical connections General The electrical installation must correspon d to the local codes. The mains sup ply and earthing lines must be of suitable size. See section 7. 1. The installation must be earthed and protected by fu se s in each phase.
Instruction book 2920 1521 00 25 SF Multi Connect the supply cable to terminals L 1, L2 and L3 of terminal strip (1X0-Fig. 1.14), co nnect the neutral conductor to terminal (N) and the earthing conductor to the earthin g bolt (1X3).
Instruction book 2920 1521 00 26 A1 Dryer (optional) F1/11 Fuses K11 Auxiliary contactor, dryer K21/24 Contactors M1/4 Motors M5 Fan motor, air cooler M6 Fan motor, bodywork PT20 Pressure sensor, air .
Instruction book 2920 1521 00 27 2.4 Pictographs Fig. 2.9 shows examples of pictograph s which may be used on the machine. 1 Automatic condensate drain 2 Manual condensate drain 3 Switch off voltage a.
Instruction book 2920 1521 00 28 3 OPERATING INSTRUCTIONS Safety precautions The operator must apply all relevant safety precautio ns, including those mentioned in this boo k. Outdoor/altitude operation If the compressor is installed outdoors o r if the air inlet temperature can be below 0 °C, p recautions must be taken.
Instruction book 2920 1521 00 29 3.3 During operation 3.3.1 Multi 1. If the automatic operation LED (8-Fig. 1.11) is alight, the regulator is aut omatically controlling the compressor modules (starting/stopping). 2. Check the readings on di splay (2-Fig.
Instruction book 2920 1521 00 30 4 MAINTENANCE Before carrying out any maintenance or repair: 1. Stop the compressor, switch off t he voltage and open the isolating switch. 2. Close the air outlet valve (2-Figs. 1.2/1.4 or 3-Figs. 1. 5/1.6) and o pen the manual drain valve: valve (1- Fig.
Instruction book 2920 1521 00 31 Period Running hours Service Plan See section See notes below table Operation Daily -- -- 3.4 -- Drain condensate " -- -- -- -- On SF Full-Feature, check dewpoint Monthly 250 -- 5.1 1 Inspect air filter 3-monthly 500 -- -- -- Check pressure drop over Atlas Copco filters (optional) 6-monthly -- -- 5.
Instruction book 2920 1521 00 32 5 ADJUSTMENTS AND SERVICING PROCEDURES 5.1 Air filter (1-Figs. 1.7/1.8) 1. Stop the compressor. Remove the filter cover and fil ter. 2. Clean the cover, if necessa ry. Discard damaged filters. 3. Fit a new filter and reinstall the cover.
Instruction book 2920 1521 00 33 5.4 Safety valve Operating Operate the safety valve by unscrewing the knurle d cap one or two turn s. Retighten the cap. Testing The valve can be tested on a separate comp ressed ai r line. If the valve does not open at the pressure marked on the valve, consult Atlas Copco.
Instruction book 2920 1521 00 34 6 PROBLEM SOLVING Before carrying out any maintenance or repair: 1. Stop the compressor, switch off t he voltage and open the isolating switch. 2. Close the air outlet valve (2-Figs. 1.2/1.4 or 3- Figs. 1.5/1.6) and o pen the manual drain valve: valve (1-Fig.
Instruction book 2920 1521 00 35 7 PRINCIPAL DATA 7.1 Electric cable size for SF1-8 Frequency Voltage SF1 single- phase SF2 single- phase SF2 3-phase SF4 3-phase SF6 3-phase SF8 3-phase IEC 50 Hz 230 V 2.5 mm² 2.5 mm² 2.5 mm² 2.5 mm² 2x 2.5 mm² 2x 2.
Instruction book 2920 1521 00 36 7.3 Overload relays for SF1-8 Frequency Voltage SF1 single- phase SF2 single- phase SF2 3-phase SF4 3-phase SF6 3-phase SF8 3-phase IEC 50 Hz 230 V 12 A 14.5 A 8.3 A 14 A 8.3 and 14 A 2x 14 A 50 Hz 400 V 4.8 A 8.2 A 4.
Instruction book 2920 1521 00 37 7.5 Main fuses for SF1-8 Frequency Voltage SF1 single- phase SF2 single- phase SF2 3-phase SF4 3-phase SF6 3-phase SF8 3-phase IEC 50 Hz 230 V 20 A 20 A 20 A 20 A 2x 2.
Instruction book 2920 1521 00 38 7.8 SF1-4 8bar 50 Hz 1) Compressor type SF1 SF2 SF4 8 bar 8 bar 8 bar Maximum working pressure bar(e) 8 8 8 Nominal working pressu re bar(e) 7 7 7 Air temperature at outlet valve (Tank- mounted/Twin), approx. °C 30 32 40 Air temperature at outlet valve (Skid), approx.
Instruction book 2920 1521 00 39 7.12 SF6-15 Multi 8 bar 50 Hz 1) Compressor type SF6 SF8 SF11 SF15 8 bar 8 bar 8 bar 8 bar Maximum working pressure for SF Pack bar(e) 8 8 8 8 Maximum working pressure for SF Full-Feature bar(e) 7 .75 7.75 7.75 7.75 Nominal working pressu re bar(e) 7 7 7 7 Air temperature at outlet valve for SF Pack, approx.
Instruction book 2920 1521 00 40 7.15 SF6-15 Multi 125 psi 60 Hz 1) Compressor type SF6 SF8 SF11 SF15 125 psi 125 psi 125 psi 125 psi Maximum working pressure for SF Pack bar(e) 9.1 9.1 9.1 9.1 Maximum working pressure for SF Full-Feature bar(e) 8.85 8.
Instruction book 2920 1521 00 41 8 REGULATOR FUNCTIONS FOR SF MULTI 8.1 Menu-driven control programs To facilitate programming and controlli ng the comp ressor, menu-d riven progr ams are implemented in the electronic module. A simplified menu flow is shown in Fig.
Instruction book 2920 1521 00 42 8.1.1 Function of control programs Program/Function Description Main screen Shows in short t he operation status of the comp ressor.
Instruction book 2920 1521 00 43 Line Indicates Remarks 1 Sensor which is active and the actual reading The unit for pressure can be bar, p si or kg/cm 2 dependi ng on the programmed selection. T he unit for temperature can be ° C or °F. See section 8.
Instruction book 2920 1521 00 44 8.1.3 Calling up other menus Starting from the Main screen: - Use the ↓ key for a quick look at the actual compressor statu s (see section 8.
Instruction book 2920 1521 00 45 8.3 Status data menu The status data submenu gives info rmation regar ding the status of the compresso r protection functions (shut-down, serv ice warning and warni ng) and allows resetting of a shut-do wn and service condition.
Instruction book 2920 1521 00 46 2. It remains possi ble to scroll through other menus, e.g. to che ck the values of other parame ters. When returning to the Status data menu, the opt ion "Shutdowns" will blink. This option can be selected by pressing the tabulator key (5) to return to the shut-do wn screen (Fig.
Instruction book 2920 1521 00 47 8.3.4 A service warning message exists 1. LED (7) is alight and the main scre en will change in to a screen similar to that sho wn in Fig. 8.9. Compressor Outlet 7.0 bar ** Service Required ** ↓ Menu *** *** - - - - F1 F2 F3 Fig.
Instruction book 2920 1521 00 48 2. By pressing the ↓ key, a number of actually measure d data can be found (see Fig. 8.1). 3. If one of the sensors i s linked to a shut-do wn, service or warning fu.
Instruction book 2920 1521 00 49 8.7 Modify parameters menu Function The menu allows the operator to progra m: - Parameters, see section 8 .8. - Protections settings, see section 8.9. - Service plan settings, see section 8.10. - Clock fun ction sett ings, see se ction 8.
Instruction book 2920 1521 00 50 8.8.1 Modifying the pressure bands If desired, the operator ca n program two pressure bands (band 1 and band 2) with different pres sure settings.
Instruction book 2920 1521 00 51 8.9 Modifying protection settings Function 1. To modify protection settings: warning (" Warning" ), e. g. Dryer LAT (Lo w Ambient Temperature) o n Full-Feature machines 2. To check some compressor conditions, e.
Instruction book 2920 1521 00 52 8.9.2 Modifying protections for Dryer LAT on Full-Fea ture machines 1. Consult the section above to select the par ameter Dryer LAT (Lo w Ambient Temperature): Dryer LAT 10 °C → Warning Maximum 25 °C ↓ Back Modify F1 F2 F3 Fig.
Instruction book 2920 1521 00 53 Important Always consult Atlas Copco i n case any timer setting should be chang ed. The intervals must not exceed the periods below and must coincide logi cally.
Instruction book 2920 1521 00 54 4. Press the tabulator key (5): a screen sim ilar to the one below will appear: Service Timer Level A 5000 hrs ↓ Menu Modify F1 F2 F3 Fig. 8.17 Service plan menu 5. The screen indicates that the level for Service plan A is set at 5000 running hours.
Instruction book 2920 1521 00 55 3. Press the tabulator key (5), following screen ap pears: Monday → Tuesday Wednes day ↓ Back Delete F1 F2 F3 4. Use the ↓ or ↑ key until the day on which a comman d must be programmed is followed by a right pointing arrow.
Instruction book 2920 1521 00 56 8.11.2 To activate/deactivate the timer 1. Starting from the Main screen (see section 8.1.2): - press the key "Menu" (F1) - press the ↓ key until the option "Modify para meters" is followed by a horizontal arrow - press the tabulator key (5) to activate the menu 2.
Instruction book 2920 1521 00 57 2. Use the ↓ key to scroll until the optio n "Clock function" is followe d by a horizont al arrow. Press the tabulator key (5), following screen app ears: Clock Functio n Not activated → Menu Modify Delete F1 F2 F3 3.
Instruction book 2920 1521 00 58 Suppose the command to stop the com pressor at 18:00 must be added to the li st of Monday: - 06:15 start - 06:15 pressure band 1 3. Press the tabulator key (5), following screen ap pears: Monday → Tuesday Wednes day ↓ Menu Delete F1 F2 F3 4.
Instruction book 2920 1521 00 59 2. Use the ↓ key to scroll until the optio n "Clock function" is followe d by a horizont al arrow. Press the tabulator key (5), following screen app ears: Clock Functio n Not activated → Menu Modify Delete F1 F2 F3 Deleting all commands Press the key "Delete" (F3) in the screen above.
Instruction book 2920 1521 00 60 5. If it is desired to modify the time, press the key "Modify ". If not, press the key "Menu" to return to the submenu. 6. After pressing the key "Modify", the first fiel d (14) will blink.
Instruction book 2920 1521 00 61 Service plans - Contact your Atlas Copco cu stomer centre fo r the service actions related to these plan s. - Consult section 8.10 if any modificati on to the intervals should be required. When the service plan interval is reached, a mess age will appear o n the screen.
Instruction book 2920 1521 00 62 3. Press the tabulator key (5): Next Timer Level ABI 10000 hrs ↓ Back Reset F1 F2 F3 Fig. 8.20 Service menu, typical example The screen shows that the next se rvice plans to be carried out ar e pla ns A, B and I and that these plans are to be carried out each 10000 runnin g hours.
Instruction book 2920 1521 00 63 8.14 Saved data menu Function To call up some compressor data saved by the regulator. These data are: - Last shut-down data - Last emergency stop data Procedure 1.
Instruction book 2920 1521 00 64 8.15 Programmable settings 8.15.1 Regulation settings Minimum setting Nominal setting Maximum setting Number of motor starts starts/day 240 720 720 Minimum stop time 1.
Instruction book 2920 1521 00 65 8.15.2 Service setti ngs Minimum setting Nominal setting Maximum setting Service Plan I hr 2000 2500 2500 Service Plan A hr 4000 5000 5000 Service Plan B hr 8000 10000.
Product: SF1-4 Skid and Tank-M ounted SF6-8 Twin SF6-15 Multi Instructions for use of air receiver 1 This vessel can contain pressuri zed air; be wa re of its potential danger in case of misuse. 2 The vessel shall only be used to store compressed ai r and shall not be subject to rapid fluctuation of pressure.
Instruction book 2920 1521 00 67 Notes:.
Instruction book 2920 1521 00 68 Notes:.
Compressor type: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Unit serial No. compressor: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Air dryer type: . . . . . . . . . . . . . . . . . . . .
1 4 . If the ground is not level or can be subject to variable inclination, consult Atlas Copco. 1 5 . The electrical connections shall correspond to the local codes. T h e units shall be grounded and protected against short circuits by fuses. Operation 1 .
デバイスAtlas Air Compressorの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Atlas Air Compressorをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはAtlas Air Compressorの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Atlas Air Compressorの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Atlas Air Compressorで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Atlas Air Compressorを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はAtlas Air Compressorの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Atlas Air Compressorに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちAtlas Air Compressorデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。