Raypakメーカー155Cの使用説明書/サービス説明書
ページ先へ移動 of 35
Part No. 240472 CATALOG NO. 6000.50-N Effective: 03-01-01 Replaces: 05-15-00 ® OPERA TING AND INST ALLA TION INSTRUCTIONS Models 155C VERSA SWIMMING POOL and SP A HEA TER This manual should be maintained in legible condition and kept adjacent to the heater or kept in a safe place for future reference.
2 3 PART ONE - Owner's Operating Instructions 3 SECTION 1 / START-UP PROCEDURES 3 Before Start-Up 4 Lighting Instructions & Shut-Off Procedures (Manually Lighted Pilot MV) 5 Operating Instruc.
3 P ART ONE - OWNER'S OPERA TING INSTRUCTIONS FOR YOUR SAFETY - READ BEFORE OPERATING WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT, CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
4 TO TURN OFF GAS TO APPLIANCE LIGHTING INSTRUCTIONS AND SHUT-OFF PROCEDURES MANUALLY LIGHTED PILOTS MILLIVOLT SYSTEM A. This appliance has a pilot that must be lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around the appliance area for gas.
OPERATING INSTRUCTIONS AND SHUT-OFF PROCEDURES AUTOMATICALLY LIGHTED PILOTS ELECTRONIC IGNITION SYSTEMS A. This appliance is equipped with an ignition device which automatically lights the pilot. Do not try to light the pilot by hand. B. BEFORE OPERATING, smell all around the appli- ance area for gas.
6 SECTION 2 / CAUTION Elevated water temperature can be hazardous, and the U.S. Consumer Product Safety Commission recom- mends the following guidelines: 1. Spa or hot tub water temperatures should never exceed 104°F (40°C). A temperature of 100°F(38°C) is considered safe for a healthy adult.
7 SECTION 3 / MAINTENANCE AND CARE PROCEDURES 4. Your pump strainer basket may be full. If so remove debris. 5. Your filter may be dirty. If so, backwash or clean filter. (To tell if your filter is dirty, the gauge pressure will be higher than usual).
COLD WEATHER OPERATION MODERATE CLIMATE: Heater operation can con- tinue during short term cold spells. When temperatures are below freezing flow, (continuous pump operation) must be maintained. CAUTION: Do not use the heater to maintain water temperatures just above freezing or for freeze protec- tion.
9 PART 2 - INST ALLA TION / SER VICE INSTRUCTIONS SECTION 1 / RECEIVING EQUIPMENT On receipt of your equipment it is suggested that you visually check for external damage to the carton. If the carton is damaged, a note should be made on the Bill of Lading when signing for equipment.
10 CLEARANCES WARNING: The heater shall not be located in an area where water sprinklers, or other devices, may cause water to spray through the cabinet louvers and into the heater. This could cause heavy internal rusting or damage some electrical components, and this would void the warranty.
11 Heaters must not be installed under an overhang of less than three (3) feet from the top of heater. Three (3) sides must be open in the area under the overhang.
INDOOR DRAFT HOOD INDOOR HEATERS The design is also certified for indoor installation when equipped with the approved draft hood. Locate heater as close as practical to a chimney or gas vent. Heater must always be vented to the outside. See Vent Piping Section for venting details.
DRAFT HOOD MOUNTING SCREWS (8) VENT TERMINAL (Outdoor) OUTDOOR STACK STEP 1 Line up (8) holes in jacket top with (8) holes in adapter assembly. STEP 2 Lower entire outdoor stack assembly on to jacket top. STEP 3 Secure with fasteners provided. VENT TERMINAL (Indoor) Locate and assemble as shown.
GAS SUPPLY CONNECTIONS Gas piping must have a sediment trap ahead of the heater gas controls, and a manual shut-off valve lo- cated outside the heater jacket.
FLOW RATES MIN GPM 20 MAX GPM 115* *When flow rates exceed 115 GPM an external auxil- iary bypass valve is required. See external auxiliary bypass valve section for details. COMPANION FLANGE CONNECTIONS DO NOT use petroleum base assembly fluids (such as Petroleum Jelly or lubricating oil).
To Pool From Pool Fig. # 8150.0 AUXILIARY BYPASS VALVE ADJUSTMENT To set bypass: With clean filter, adjustment is made by feeling the inlet and outlet pipes at the heater. Outlet pipes should be slightly warmer than inlet and comfort- able to the touch.
NOTE: To avoid water damage or scalding due to valve operation, drain pipe must be connected to valve outlet and run to a safe place of discharge. Drain pipe must be the same size as the valve discharge connection throughout its entire length and must pitch downward from the valve.
WIRING DIAGRAM KEY 18 Fig. # 8096.0 For 120 V input power to the unit, connect the black wire to the “L1” or hot leg of the power supply . Connect the white wire to the “L2” or neutral leg of the power supply . Attach the wire nut to the red wire.
19 WIRING DIAGRAM MILLIVOLT UNITS Fig. #2182e.
20 WIRING DIAGRAM 152148 Model 155 IID BL BL BL.
VIEW OF HEATER FROM FRONT VIEW OF HEATER FROM BACK SECTION 4 / SERVICING INSTRUCTIONS GENERAL LOCATION OF CONTROLS 21 CONTROL PANEL REMOVAL 1. Remove lower door. 2. Remove (2) screws from bottom flange of control panel. 3. Slide down control panel to clear jacket top panel.
Fig. # 8069.1 PRESSURE SWITCH ADJUSTMENT RANGE Fig. # 8152.0 NOTE: If heater is installed outside of the limits shown, a flow switch must be used in place of the pressure switch when mounted and wired adjacent to the heater.
PILOT SAFETY (Millivolt System) The heaters equipped with the standing pilot (millivolt system), have pilot generators which act as a safety device to shut off the flow of gas to the main burners and the pilot burner in case the pilot flame is extinguished.
24 HEAT EXCHANGER REMOVAL 1. Shut water, gas and electricity off, close valves and relieve pressure, remove relief valve. Re- move side inspection panels. 2. Remove top holding screws. 3. Remove draft diverter, lift and remove top and flue collector on stack-type models.
DESOOTING PROCEDURE CAUTION: SOOT IS COMBUSTIBLE. EXERCISE EXTREME CARE. Soot can clog areas between fins and cause even- tual tube failure. Any sign of soot at the base of the burners or around the outer jacket indicates a need for cleaning. 1. Remove top and flue collector from cabinet.
SECTION 5 / TROUBLE SHOOTING GUIDE These instructions are primarily intended for the use of qualified personnel specifically trained and experienced in the installation of this type of heating equipment and related system components. Installation and service personnel may be required by some states to be licensed.
If pilot burner remains lit. Jump across pressure switch terminals If main burner does not fire, remove jumper Check for adequate water flow from filter Replace pressure switch Jump across thermostat If main burner fires, remove jumper If main burner does NOT fire.
ELECTRICAL (ELECTRONIC IGNITION IID) 28 WARNING HIGH VOLTAGE For qualified Technicians ONLY NOTE: Some heaters may be equipped with an ignition module that shuts off pilot gas if pilot fails to light.
ELECTRICAL (SOLID STATE THERMOSTAT IID) If the pool/spa/hot tub water is too cold, troubleshoot the system as follows: Check voltage at 24 V terminals. VOLTAGE BETWEEN 21.5-28.5 V. Set control to max. temperature. After 2-3 cycles, check water temperature.
30 SECTION 6/REPLACEMENT PARTS LIST NOTE: To supply the correct part it is important that you state the model number, serial number and type of gas when applicable.
31.
32.
33.
LIMITED WARRANTY RAYPAK RESIDENTIAL SWIMMING POOL AND SPA HEATERS GENERAL Raypak, Inc. warrants that the cabinet, burner tray (minus controls) and refractory will be free from defects in materials and.
Raypak, Inc. , 2151 Eastman Avenue, Oxnard, CA 93030 (805) 278-1500 FAX (800) 872-9725 Raypak Canada LTD , 2805 Slough Street, Mississauga, Ontario, Canada L4T 1G2 (905) 677-7999 FAX (905) 677-8036 Raypak Australia Pty. Ltd , 7 Geddes St., Mulgrave, Victoria, Australia 3170 (6139) 560 4944 FAX (6139) 560 4974 Litho in U.
デバイスRaypak 155Cの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Raypak 155Cをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはRaypak 155Cの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Raypak 155Cの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Raypak 155Cで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Raypak 155Cを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はRaypak 155Cの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Raypak 155Cに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちRaypak 155Cデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。