® A N I N D E P E N D E N T L A B O R A T O R Y T E S T I N G F O R P U B L I C S A F E T Y G 028 Read this manual and all labels carefully before operating your powder actuated tool. This manual should always accompany the tool and be transferred with it upon change of ownership.
2 101437 Maximum 3" (76 mm) * Not provided with tool Power Load* Trigger Muzzle/Guide Recommended Approved Goggles* Power Fastener* Spall Shield Barrel Assembly REMINGT ON Model 494 Powder Actuat.
3 101437 W arning: Safety Precautions The following pages contain detailed warnings, cautions, and rules of safe operation. Read carefully and become familiar before operating to avoid serious injury.
4 101437 482-12 G 018 G 018 G 018 Safety Precautions 5. ALWAYS make sure the work area is clean from loose material and debris. 2. NEVER place your finger on the trigger until the tool’s muzzle is against the work surface. 1. NEVER place your hand over the muzzle.
5 101437 482-19 482-24 G 018 G 018 G 018 G 018 Safety Precautions 3. ALWAYS store UNLOADED powder actuated tool and power loads in a locked container. Keep power loads of different power levels in separate containers. 4 . NEVER carry or pass a loaded powder actuated tool.
6 101437 TOO HARD Point flattens 482-29 ? ? ? 482-25 TOO BRITTLE Surface shatters 482-30 TOO SOFT Sinks in with average hammer blow 482-28 G 018 G 018 G 018 G 018 Safety Precautions 1. ALWAYS know the thickness and type of base material into which you are fastening.
7 101437 CAST IRON GLASS TILE BRICK 482-33 Safety Precautions 3. NEVER make fastenings in spalled or cracked areas. 2 . NEVER attempt to drive power fasteners into very hard or brittle materials including, but not limited to cast iron, glass, tile, stone, brick, or hardened steel.
8 101437 TOO THIN WELD 482-40 G 018 G 018 Safety Precautions 7. DO NOT drive power fasteners into steel base material less then 3/16" thick, within 2" of a weld, within 1/2" of the edge or within 1" of another power fastener.
9 101437 POWER LOADS POWER LOADS 482-49 GASOLINE GAS OLINE 482-50 G 018 G 018 G 018 G 018 Safety Precautions 2. Should the tool fail to fire, hold the muzzle firmly against the work surface for 30 seconds. Release the trigger and remove pressure on the tool while holding the muzzle against the work surface.
10 101437 482-58 YELLOW? BROWN? GREEN? GRAY? G 018 2. Remington power loads are available in four power levels with gray (1) being the lowest power level and yellow (4) being the highest power level. Always start with the lowest power level (gray-level 1) and increase until a proper fastening is made (see page 13 Selecting Fasteners and Loads).
11 101437 482-59 G 018 Safety Precautions 6. Power fasteners are a permanently installed fixture. An act of demolition is required for their removal. Appropriate safety precautions must be taken. Plastic Flute Shank Head 482-60 7. NEVER use common nails or other materials as fasteners.
12 101437 WHY A POWER FASTENER HOLDS IN CONCRETE The compression bond of the concrete to the power fastener accounts for the majority of the holding power. The fastener dis- places the concrete which tries to return to its original form causing a squeezing effect.
13 101437 FASTENING INTO CONCRETE The proper power fastener length can be determined by adding the thickness of the material to be fastened and the amount of fastener that will actually penetrate the concrete. The concrete must be three times as thick as the intended fastener penetration.
14 101437 Operation 1. Grasp muzzle and slide barrel forward rapidly until it stops. This sets piston into firing position and opens the chamber. 4. Push barrel into housing to the closed position. 3. Select the proper Remington Power Load and insert into the chamber until it stops (see Application Chart on page 23).
15 101437 WATER Operation 5. Place the muzzle of tool perpendicular to work surface without tilting the tool. Push tool against work surface until sliding action of barrel stops. 8. Should the tool fail to fire, hold the muzzle firmly against the work surface for 30 seconds.
16 101437 Tang Tang Spring Tang Cap Buffer Muzzle Cap Piston Barrel Receiver Maintenance T roubleshooting Guide PROBLEM Piston rod hangs out of muzzle cap. Overdriving of power fastener. Piston jammed. Expended power load will not extract. Reduction or loss of power.
17 101437 T roubleshooting Guide (cont.) PROBLEM Tool does not completely depress. Tool does not fire. Opening and closing of barrel or pushing down of the tool, etc. is not smooth but is rough or binds. REMEDY Remove breech and check all parts for correct fit assembly.
18 101437 Parts List – Model 494 KEY PART NO. NO. DESCRIPTION QTY. 1 101123-01 Screw, 1/4"-20 x 1.25 2 2 101122-01 Washer 2 3 101128-01 Handle & Trigger Assembly 1 4 056217 Firing Pin Sprin.
19 101437 Accessories DISASSEMBLY 1. a) Remove tang cap, tang spring, and tang. Slide barrel assembly from receiver. b) Remove muzzle cap from barrel by un- screwing counterclockwise. Barrel Assembly Muzzle Cap Barrel Tang Tang Spring Tang Cap Receiver Receiver Screws Firing Pin Spring Handle and Trigger Assembly Firing Pin Sear Spring Sear 2.
20 101437 T ool Disassembly and Assembly WARNING: Always unload a powder actuated tool before disassembling, replacing barrel, cleaning, or assembling. ! WARNING ICON G 001 ASSEMBLY 1. Place buffer, small end first, in muzzle cap. Push piston all the way into the barrel.
21 101437 Buffer and Piston Replacement ! WARNING ICON G 001 WARNING: Always unload a powder actuated tool before disassembling, replacing barrel, cleaning, or assembling. Breech Receiver Barrel Assembly Slot in Barrel Tang Cap Tang Spring Tang 3. Reinsert barrel assembly slotted side down into receiver.
22 101437 482-81a Two by fours Furring strips Metal electrical junction boxes Conduit clips Shelf brackets 1/4" Plywood or pegboard For fastening this Power load and power fastener application information.
23 101437 Application Chart IMPORTANT • If power fastener goes below the top surface of the board, use penetrating control disc (* see illustration below). • Always wear approved eye and ear protection. 482-90 * Use power fastener with penetration control disc, part number 015549.
Limited W arranty Agreement DESA International warrants the Remington Model 494 Powder Actuated Fastening Tool against defects in materials and workmanship for a period of one (1) year from the date of purchase.
デバイスRemington Power Tools 494の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Remington Power Tools 494をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはRemington Power Tools 494の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Remington Power Tools 494の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Remington Power Tools 494で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Remington Power Tools 494を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はRemington Power Tools 494の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Remington Power Tools 494に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちRemington Power Tools 494デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。