ResMedメーカーAutoSet CS 2の使用説明書/サービス説明書
ページ先へ移動 of 112
A utoS et CS ™ 2 User ’ s Manual English • Français Front Cover - User.qxp 03/11/2006 8:44 AM Page 1.
Global leaders in sleep and respiratory medicine www .r esmed.com 26861/5 06 1 1 AutoS et CS 2 User EUR 1 Bleed this panel onto spine (if applicable) but NOT onto Front Cover Front Cover - User.
U SER ’ S M ANUAL 1 M ANUE L UTILISAT EUR 5 5 A utoSet CS ™ 2 F RANÇAIS E NGLISH multi title .fm Page 3 Friday, November 3, 2006 2:41 PM.
ResMed L td (Manufacturer) 1 Elizabeth Macarthur Drive Bella V ista NSW 2153 Australia ResMed C orp (US Designated Agent) 14040 Danielson Str eet Po way CA 92064-6857 USA ResMed (U K) Ltd (EU Authoriz.
1 USER’S MANU AL English A UTO S ET CS ™ 2 E NGLISH eng.book Page 1 Friday, November 3, 2006 2:43 PM.
2 eng.book Page 2 Friday, November 3, 2006 2:43 PM.
3 T ABLE OF C ONT ENTS E NGLISH T ABLE OF C ONTENTS I NTRODU CTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 A UTO S ET CS2 5 U SER / OWNE R RESPONSIBILITY 5 M EDICAL I NFORMATI ON 5 I NTENDE D U SE 5 C ONTRAINDICAT IONS 5 W ARNINGS 6 C AUTIONS 6 Q UICK S ET UP G UIDE .
4 H IGH LEAK ALARM 32 I NSUFFICIENT PRE SSURE SUPPORT ALARM 33 F LOW BLOCKE D ALARM 33 C LEANING AND M AIN TENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 D AILY 35 W EEKLY 35 P ERIODIC ALLY 36 A IR F ILTER 36 H YPOALLER GENIC AIR FI LTER 37 S ERVI CING 37 T ROUBLESHOOTI NG .
5 I NTRO DUCTI ON E NGLISH I NTRODUCTION A UTO S ET CS2 The A UTO S ET CS 2 ™ flow gen erator has been designed to be relia ble, comfortable and easy to use. You can observe your treatment and make adjustments to settings using a keypad and LCD screen.
6 ! W ARNINGS • The A UTO S ET CS2 is NOT a life support ventila tor. • The entire manua l should be read before u sing the A UTO S ET CS2 . • Advice contai ned in this manual should not supersede instruct ions given by the prescribing physician.
7 Q UICK S ETUP G UIDE E NGLISH Q UICK S ETUP G UIDE 1 Attach t he air tubin g and pressure sensor tube t o the A UTO S ET CS2 and mask (page 11). 2 Attach a humidifier if required (page 13). 3 Switch on the A UTO S ET CS2 . Make sure the mask is unb locked.
8 eng.book Page 8 Friday, November 3, 2006 2:43 PM.
9 T HE A UTO S ET CS2 S YSTEM E NGLISH T HE A UTO S ET CS 2 S YSTEM A UTO S ET CS2 C OMPONENT S The A UTO S ET CS2 flow gener ator is supplied with air tubin g and a power cord. Masks are supplied separately, as you and your clinician have to decide which mask is best for you.
10 Figu re 3: Air t ubin g full y as sembled All necessary air tub ing components are packed with t he A UTO S ET CS2 : • a 2-metre length of a ir tubing • a pressure sensor tub e (to measure pres.
11 T HE A UTO S ET CS2 S YSTEM E NGLISH A SSEMBLING THE A UTO S ET CS2 S YSTEM Complete the follo wing steps to assemble the A UTO S ET CS 2 system. Make sure the area around th e unit is clean (dust free) and clear of bedding, clothes a nd any other potential bloc kages.
12 2 Connect air tubing Connect the air tube firmly onto the air outle t at the front of the unit. Figu re 4: F ront v iew of AutoSe t CS2 To attach the pressu re sensor tube to the unit, screw the Luer connector onto the socket on the side of th e unit.
13 T HE A UTO S ET CS2 S YSTEM E NGLISH 3 Attach the mask to the air tubing. The mask system should alr eady be assembled. If it is not, please r efer to the user instructions suppli ed with the mask. Connect the mask system to the free end of the air tub ing.
14 C ONNEC TING A HUMIDIFIER N OTE After co nnecting or r emoving a humidifier, alway s perform t he Air Circuit Learn function (see page 26). ! WARNING When using a humid ifier, positio n it so that it is lower t han yo ur hea d will be duri ng sleep, and at th e same level or lower than the A UTO S ET CS2 .
15 T HE A UTO S ET CS2 S YSTEM E NGLISH H UMID A IRE You will need a Medium size (5 2cm) air tube to connect the A UTO S ET CS2 un it to t he H UMID A IRE ™ (see Figure 7 ). 1 Make sure both the H UMID A IR E and the A UTO S ET CS2 ar e turned off. Fill the H UMID A IRE with wa ter as described in the humidifier manual.
16 4 Connect the free e nd of the medium air tubing to th e A UTO S ET CS2. Connect the pressure senso r tube by twisting the Luer l ock onto the A UTO S ET CS2 ( see page 12). 5 Connect the mask system to the free end of the long a ir tubing. The final assembly should look like t his: 6 Switch on the H UMID A IRE and the A UTO S ET CS 2 .
17 T HE A UTO S ET CS2 S YSTEM E NGLISH ! CAUTIO N • Be very care ful not to allo w water to enter the A UT O S ET CS2 as this could a ffect ther apy an d/or d amag e the de vice. • Do not tip the H UMID A IRE while it is connected to th e A UTO S ET CS2 .
18 Figu re 10 : Inse rtin g an ti-ba cteri al fi lte rs U SING DC P OWE R TO R UN THE A UTO S ET CS 2 The A UTO S ET CS2 c an b e r un o n D C c u r r en t i n c a s e o f p o w er f a il u r e or fo r po r t a bl e use. ResMed supplies a conv ertor that allows a 12 V battery to be connected to the DC input of the A UTO S ET CS 2 .
19 T HE A UTO S ET CS2 S YSTEM E NGLISH U SING S UPPLEME NTAL O XY GEN If oxygen is being ad ded at the mask, the ox ygen tub e is attached to the mask port. Refer to your mask manual for full instructions. Up to 15 L/min of oxygen can be added at the mask wh en using an A UTO S ET CS2 system.
20 eng.book Page 20 Friday, November 3, 2006 2:43 PM.
21 U SING TH E A UTO S ET CS2 E NGLISH U SING THE A UTO S ET CS2 ! WARNING Befor e star ting th erapy with a new m ask, s elect th e corr ect ma sk typ e in t he Settings menu (page 26). Whe n adding or r emoving a new co mponent such as a mask, hu midifier o r anti-bact erial fi lter, perfo rm the Air Ci rcuit L earn func tion (page 26) .
22 C ONTROL P AN EL F UN CTIONS The control panel of the A UT O S ET CS 2 has a keypad that a llows you to: • start or stop treatmen t • adjust setting s on the flow generator • mute or stop alar ms • view treatment data .
23 U SING TH E A UTO S ET CS2 E NGLISH L EFT KEY ( GREEN ) • Enters a menu. • Confirms and app lies settings. • Performs the function indi cated by the text above it in the LCD (eg ’enter’, ’c hange’). R IGHT KEY ( RED ) • Performs the fun ction indicated by the text ab ove it in the LCD (eg ’e xit’).
24 • Once you find the o ption you require, press the Le ft key to select the function that is displayed in the bottom left of the screen eg ’ch ange’, ’yes’. • Use the Up/D own key to alter the paramete rs, and press the Le ft key when you have the setting y ou require.
25 U SING TH E A UTO S ET CS2 E NGLISH M ENUS The options availab le in the Settings menu will d epend on the therapy you ar e receiving, set by your clinician. Figure 16: Naviga ting t he Patien t menu. LOW PS:ON A VG PRESS: 10.4 SW: SX245-0117 These menus appear only i f at least o ne Smart D ata o ption has been enabled by the c linicia n.
26 S ETTINGS MENU You will only see the options relevant to your therapy. In CPAP (Continuous Positive Airway Pressure) mode, the clinician sets a pressure th at will be constant throughout treatment. In ASV-CS mode, A UTO S ET CS2 continuall y measures your b reathing and regulates the air p ressure accordingly.
27 U SING TH E A UTO S ET CS2 E NGLISH 7. When the functi on is complete, a screen will appear saying that the circuit ha s been learned successfully. The next menu item is then d isplayed. Commence treatment as descr ibed in “Starting Treatment” on p age 21.
28 M ASK FIT Gives a rating of how well the mask was fitting during your last session on the A UTO S ET CS2 . The sta rs indicate how good the fit was (more stars = b etter fit). A VERA GE P RE SSUR E Provides informati on on the a verage air p re ssure during your most recent session on the A UTO S ET CS2 .
29 U SING TH E A UTO S ET CS2 E NGLISH S ERVI CING MENU This menu displays the followin g information: • SN – the flow generator ’s serial number • PCB – the flow gener ator’s PCB number (PCB — printed c ircuit board) • SW – the vers ion of software currently instal led on the flow generator.
30 eng.book Page 30 Friday, November 3, 2006 2:43 PM.
31 T HE A LARMS E NGLISH T HE A LA RMS The A UTO S ET CS2 unit is fitted with alarms to alert you to changes that will affect your treatment. The most common reason for an alarm to so und is because the system h as not been properly assembled .
32 W ILL CLEA R WHEN : • the low pressure cond ition is fixed • treatment is stopped by p ressing the Start/Stop key. P OWER FAI L ALARM T RIGGER ED BY : • power failure • machine is discon nected or switched off while deliver ing treatment. I F A POWER FAIL ALARM SOUND S : • The flow genera tor stops deliv ering air pressu re.
33 T HE A LARMS E NGLISH W ILL STOP WHEN : • the mask leak has been rectified. N OTE The High Le ak alarm can be turne d off in the Leak Alert option in the Settings me nu.
34 eng.book Page 34 Friday, November 3, 2006 2:43 PM.
35 C LEANING AND M AINTENANCE E NGLISH C LEANING AND M AI NTENANCE You should regular ly carry out the cleaning and mainten ance described in this manu al. ! CAUTIO N Do not w ash the pre ssure sen sor tube . If fluid ente rs the pres sure se nsor tube al low it to d ry compl etely by h anging i t in a cl ean place out of dir ect sunl ight.
36 ! CAUTIO N • Do no t use b leach, chlori ne-, a lcohol- or arom atic-bas ed sol utions ( includi ng all scente d oils), m oistur ising or antiba cterial s oaps to clean the c ushion , mask, a ir tubing or th e A UTO S ET CS2 . These sol utions may cause h ardening and red uce the life o f the product.
37 C LEANING AND M AINTENANCE E NGLISH ! WARNING Do not wash the air filter once it has become so iled. The air filter is not washable or reus able. F ITTING THE FILTER • Remove the filte r cover at the back of the flow ge nerator. • Remove and disca rd the old air filter.
38 eng.book Page 38 Friday, November 3, 2006 2:43 PM.
39 T ROUBLESH OOTI NG E NGLISH T ROUBLESHOOTING If there is a problem, try the following suggestions. If the problem cannot be solved , contact your equipm ent supplier or ResMed. Do not a ttempt to open the flow generator. Proble m Pos sible cau se Solutio n Insuff icien t air deli vere d from flow generator Air filter is dirty .
40 eng.book Page 40 Friday, November 3, 2006 2:43 PM.
41 G LOSS ARY E NGLISH G LOSSARY Alarms : When more than on e alarm is activated at the on e time, the highest priority alarm will be displayed. Backli ght : The backlight turns off if no b utton has been pressed for two minut es. It can also be kept perman ently on by selecting Auto in the Backlight screen of the Options menu.
42 eng.book Page 42 Friday, November 3, 2006 2:43 PM.
43 T ECHNICAL S PECIFIC ATIONS E NGLISH T ECHNICAL S PECIFICATIONS D IMENS IONS (H X W X D) 142 x 248 x 293mm (5.6 " x 9.8" x 11 .5") W EIGHT Flow generato r with cover: 3.
44 • I NSUFFICIENT PRESSURE SUPPORT ALARM Is triggered if for 3 breaths in a row the maxi mum mask pressure achie ved at inspiratory to ex piratory transition is either <87.5% of th e absolute mask pressure targetted at tha t point, or < absolute mask pressure target ted minus 1 cmH 2 O, whichever is th e lower.
45 T ECHNICAL S PECIFIC ATIONS E NGLISH P RESSURE V ARIATIO N P RESSURE V OLU ME C URVE N OTE The m anufacturer reserves the right to chang e these specif ications without not ice. 0 2 4 6 8 10 12 14 16 0123 10BP M 15BP M 20BP M Breat hs Pre ssure (cm H 2 O) 1/3 Max Pressure 2/3 Max Pressure Max Pressure 0 100 200 300 400 500 600 4 .
46 G LOSSARY OF SYMB OLS Read this Operating Ma nual before using Type CF e quipment AC switch Class II Environmental information WEEE 2002/96/EC is a European Directiv e that requires the prop er disposal of electrical and electronic eq uipment. This device should be disposed o f separately, not as unsorted municipal waste.
47 T ECHNICAL S PECIFIC ATIONS E NGLISH G UIDANCE AN D M ANU FACT URER ’ S D ECLARATION — E LECTROMAGNET IC E MISSI ONS AND I MMUNITY Guidance and manuf acturer’s declarat ion – electrom agnetic emission s The Au toSe t CS2 is in tend ed for us e in the el ectro magn etic env ironm ent spe cifi ed bel ow .
48 (Conti nued next page) Guidance and manuf acturer’s declara tion – electroma gnetic immuni ty The Au toSet CS2 is intend ed for use in the el ectro magnet ic env ironmen t spec ified b elow . The cus tomer or the user of the AutoSet CS2 should assure that it is used in such an e nvironment.
49 T ECHNICAL S PECIFIC ATIONS E NGLISH Guidance and manufacture r’s declaration – electromagneti c immunity ( continued) The A utoSet C S2 is intend ed for use in t he ele ctro magnet ic env ironme nt sp ecified belo w . The c usto mer or t he user of the AutoSet CS2 sh ould assure that it is used in such an environment.
50 Recomme nded separation dis tances between portabl e and mobile RF communi cations equipment and the AutoSet CS2 The A utoSet CS2 is intend ed fo r use i n an env ironme nt in which radia ted RF d istu rbanc es are co ntro lled.
51 L IMI TED W ARR ANTY E NGLISH L IMITED W ARRANTY ResMed warrants that your ResMed product sh all be free from defects in mate rial and workmanship for the period specified below from the date of pur chase by the initial consumer. This warranty i s not transferable.
52 eng.book Page 52 Friday, November 3, 2006 2:43 PM.
53 I NDEX E NGLISH I NDEX A air circuit learn function 26 air filter 36 hypoallergenic 37 air pres sure monitoring 28 air tubing attachi ng to mask 13 cleaning 35 connecting 12 air tubing system 9 , 1.
54 Smart data 28 SmartS top 27 sound level 27 standby mode 21 star ting trea tment 21 stopping treatm ent 21 supplemental oxygen 19 Syst em Erro r 7 me ssage 39 T treatment scr eens 29 U user/owner res ponsibility 5 eng.
55 MANUEL UTILISATEU R França is A UTO S ET CS ™ 2 F RANÇAIS fre.book Page 55 Friday, November 3, 2006 2:45 PM.
56 fre.book Page 56 Friday, November 3, 2006 2:45 PM.
57 S OMMAIRE F RANÇAIS S OMMAIRE I NTRODU CTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 A UTO S ET CS2 59 R ESPONSABILITE DE L ’ UTILISATEU R / DU P.
58 A LARME DE FU ITE IM POR TAN TE 87 A LARME D ’ AIDE INSPIRATOIRE INSUFFISANT E 87 A LARME DE DE BIT BLOQUE 87 N ETTOY AGE ET ENTR ETIEN . . . . . .
59 I NTRODU CTION F RANÇAIS I NTRODUCTION A UTO S ET CS2 L’ A UTO S ET CS ™ 2 a été conçu pour être facile à u tiliser tout en vous procuran t fiabilité et confort. Vous pouvez suivr e votre traitement et ajuster les réglages à l’aide d’un clavier et de l’écran LCD.
60 ! A VERTISSE MENTS • L’ A UTO S ET CS2 n’est PAS un vent ilateur de réanimation. • Lire le manuel en tièrement avant d’util iser l’ A UTO S ET CS2 . • Les conseils donn és dans ce manuel ne remp lacent pas les instructions d u médecin traitant.
61 G UIDE D ’ INSTALLATION RAPI DE F RANÇAIS G UIDE D ’ INSTALLATION RAPIDE 1 Raccor dez le circui t respirat oire et le tube capteur de press ion à l’ A UTO S ET CS2 et au masque (page 65). 2 Fixez un humidificateur le cas échéant (page 67).
62 fre.book Page 62 Friday, November 3, 2006 2:45 PM.
63 A UTO S ET CS2 F RANÇAIS A UTO S ET CS2 C OMPOSANTS DE L ’A UTO S ET CS2 L’ A UTO S ET CS2 est fourni avec u n circuit respiratoire et un câble d’alimentation. Les masques sont fournis sép arément, car vous devez décider quel masq ue vous convient le m ieux en collaboration avec votre clinicien.
64 Figu re 3 : Circui t respir atoi re entièr ement as semblé Tous les composants néc essaires du circuit r espiratoire sont fournis avec l’ A UTO S ET CS2 : • un tuyau à air de 2 mètres de l.
65 A UTO S ET CS2 F RANÇAIS M ONT AGE DE L ’A UTO S ET CS2 Suivez les étapes suivantes pour monter l’ A UTO S ET CS2 . Veillez à ce que la zone autour de l’appareil soit p ropre (exempte de poussière) et exemp te de literie, vêtements ou toute autr e source potentielle de blocag e de l’alimentation en air .
66 2 Raccordez l e circuit respiratoir e. Raccordez le circuit r espiratoire fermement à la sortie d’air situ ée à l’avant de l’ap pareil. Figu re 4 : Vue avant d e l’AutoSet CS2 Pour fixer le tube capteur de pression à l’ap pareil, vissez le raccord Luer dans la prise située sur le côté de l’ap pareil.
67 A UTO S ET CS2 F RANÇAIS Raccordez le masque à l’extr émité libre du circuit respir atoire. Figu re 6 : Montag e de l’Auto Set CS2 H UMID IFIC ATEU RS Il est possible que vous ayez besoin d'un humidificateur pour pallier les problèmes de sécheresse nasale, buccale ou de la gorge.
68 R ACCO RDEMEN T D ’ UN HUMIDIFICATEUR R EMARQUE Aprè s avoir rac cordé ou r etiré un hum idifi cateur, exécutez s ystémat iquement l a fonction d’ident ifica tion du cir cuit res pirat oire (voi r page 80 ).
69 A UTO S ET CS2 F RANÇAIS H UMID A IRE Un tuyau d’une lon gueur moyenne (52 cm) est r equis pour raccorder l’ A UTO S ET CS2 à l’ H UMID A IRE ™ (voir Figur e 7). 1 Vérifiez que l’ H UMID A IRE et l’ A UTO S ET CS2 sont hor s tension.
70 4 Raccordez l’extrémité libre du tuyau à air de longueur moyenne à l’ A UTO S ET CS2 . Raccordez le tube capteur de pression en vissant le raccord Luer sur l’ A UTO S ET CS2 ( voir page 66). 5 Raccordez votre masque à l’extrémité libre du long tuyau à air.
71 A UTO S ET CS2 F RANÇAIS ! ATTENTI ON • Ne pas laisser d’eau s’écouler dans l’ A UTO S ET CS2 au risque de compromettre le traitement et/ou d’endommag er l’appareil. • Ne pas retourner l’ H UMID A IR E lorsqu’ il est raccordé à l’ A UTO S ET CS 2.
72 Figure 10 : Mi se en pl ace des filtre s anti bactérien s U TILISAT ION D ’ UNE A LIMENTA TION CC AV EC L ’A UTO S ET CS2 L’ A UTO S ET CS 2 peut fo nctionner sur c ourant continu en cas de pan ne de courant ou pour une utilisation ambulatoire.
73 A UTO S ET CS2 F RANÇAIS U TILISAT ION D ’ OXY GENE SUPPLEMENTAIRE Si de l’oxygène est ajouté au niveau du masq ue, le tube à oxygène est r accordé au port du masque. Veuillez vous r éférer au manuel du masque pour les instructions complètes.
74 fre.book Page 74 Friday, November 3, 2006 2:45 PM.
75 U TILI SAT ION DE L ’A UTO S ET CS2 F RANÇAIS U TILISATION DE L ’A UTO S ET CS2 ! AVERTISSEMENT Avant de c ommencer le trait ement avec u n nouveau ma sque, sé lection ner le type correct de masque dans le menu Régl ages (page 80).
76 menu Résu ltats s'affichent au tomatiqueme nt pe ndant environ 2 0 minutes aprè s la fin de votre séanc e de traitement. F ONCTIONS DU PANN EAU DE CONTROLE Le panneau de contrôle d e l’ .
77 U TILI SAT ION DE L ’A UTO S ET CS2 F RANÇAIS T OUCHE DE GAUCHE ( VER TE ) • Permet d’accéder aux menus. • Permet de con firmer et d’app liquer les ré glages. • Permet d’exécuter la fonct ion indiquée par le texte d’explication affi ché sur l’écran LCD au-dessus de cette touche (p.
78 Pour modifier un r églage, appuyez sur la touche de déplacement vers le haut/bas jusqu’à ce que le menu souhaité s’affiche. • Appuyez sur la touche de gauche p our ouvrir le menu, puis servez-vous de la touche de déplacement vers le haut/bas pour faire défiler les options.
79 U TILI SAT ION DE L ’A UTO S ET CS2 F RANÇAIS M ENUS Les options disponibles dans le me nu Réglages dépenden t du traitement que vous recevez et qui a été réglé par votre clinicien.
80 M ENU R EGLAG ES Vous ne pouvez v oir que les op tions qui concernent votr e traitement. En mo de CPAP (de l’anglais Continuous Positi ve Airway Pressure - pression positive continu e), le clinicien règle la pression pour qu’elle soit consta nte pendant tout le trait ement.
81 U TILI SAT ION DE L ’A UTO S ET CS2 F RANÇAIS 6. Un écran de progr ession s’affiche pendant que la fonction d’identificatio n du circuit respiratoire est exécu tée. 7. Une fois que cela est t erminé, un écran s’affiche pour vou s indiquer que l’identificatio n du circuit a réussi.
82 M ENU R ESULTA TS Ce menu com pren d un e s érie d’é cra ns v ous donn an t de s inf orm ati on s sur votr e dernière séance de traitement. Si elles ont ét é activées par votre cl inicien,.
83 U TILI SAT ION DE L ’A UTO S ET CS2 F RANÇAIS "changer" en appuyant su r la touche de gauche pour passer de ON à OFF (et vice versa). Votre clinicie n peut également désacti ver AFFIC. AUTO . R ETRO - ECL . ON : rétro-éclairage de l’éc ran LCD allumé en pe rmanence.
84 Figure 1 8 : Ecran de trait ement 2 Figure 1 9 : Ecran de trait ement 3 R EMARQUE CIBL n'est pas un paramètre utilisé en mode CPAP. APNE VC: 428 LK:18 l/min FR:12 Fuite Fréqu ence respiratoi re Apnée / Hypopnée Volume courant (le cas é chéant) VM:6,2 CIBL:5,8 quit Ventila tion minut e Ventil ation cibl e fre.
85 L ES ALARMES F RANÇAIS L ES ALARMES L’ A UTO S ET CS2 possède des alarmes qui vous avertissent des changements qui peuvent comprome ttre votre traitement. La raison la pl us courante de déclen chement d’une alarme est le monta ge incorrect du système.
86 S I UNE ALARME DE PRESSION BAS SE SE DECLENC HE : 1. Vérifiez que le t uyau à air et le tube capteu r sont correctement raccordés. 2. Mettez l’ A UTO S ET CS2 hors tension puis à nouveau sous tension a u niveau de l’interrupteur pr incipal.
87 L ES ALARMES F RANÇAIS A LARME DE FUITE IMPORT ANTE D ECLENCHEE LORSQUE : • une fuite import ante (supérieure à 30 l/min) se produit pendan t plus de 20 secondes. S I UNE ALARME DE FUITE IMPORTAN TE SE DECLENC HE : • Ajustez le masque p our minimiser les fuites.
88 fre.book Page 88 Friday, November 3, 2006 2:45 PM.
89 N ETTOYAGE ET ENTRETIEN F RANÇAIS N ETTOYAGE ET ENTRETIEN Vous devez effectuer régu lièrement le nettoyage et l’en tretien décrits dans ce manu el.
90 Figu re 20 : Démonta ge du circui t respira toire po ur le nettoy age ! ATTENTI ON • Ne pas u tiliser de soluti ons à bas e d’eau d e Jave l, de chlo re, d’a lcool ou d’aro mates (y c omp.
91 N ETTOYAGE ET ENTRETIEN F RANÇAIS ! ATTENTI ON Ne pas essaye r d’ouv rir l’ A UTO S ET CS2 . Des piè ces ne pouvant êt re entretenues par l’ utilisa teur se tr ouvent à l’intérie ur. Les réparat ions et l’e ntret ien inte rne doivent être effectués par un tec hnicien agréé.
92 E NTRETI EN Ce produ it (l’ A UTO S ET CS 2 ) doit être inspecté par un servi ce technique agréé ResMed 5 ans après la date de sa fabrication. Avant cette d ate, l'appareil devr ait assurer un fonctionnement fiab le et sûr à condition qu'il soit utilisé et entretenu conformément aux instructions donn ées par ResMed.
93 S TRATEGIE DE DEPA NNAGE F RANÇAIS S TRATEGIE DE DEPANNAGE En cas de pro blème, reportez-vous au x suggestions suivantes. Si le problème persiste, contactez votre prestat aire de santé ou ResMed.
94 fre.book Page 94 Friday, November 3, 2006 2:45 PM.
95 G LOSSAIR E F RANÇAIS G LOSSAIRE Alarmes : lorsque plusieurs alarmes sont activées simult anément, c’est l’alarme de la plus haute priorité q ui est affichée. bpm : respirations par minute. l/min : litres par minute. Manchon proximal : un raccord entre le circuit respiratoire et le masque.
96 fre.book Page 96 Friday, November 3, 2006 2:45 PM.
97 C ARACTERIS TIQUES F RANÇAIS C ARACTERISTIQUES D IMENS IONS (H X L X P) 142 x 248 x 293 mm P OIDS Appareil avec pro tection : 3,7 kg Appareil avec l’ H UMID A IR E 2 I (vide) : 4,2 k g C ONDI TI.
98 • A LARM E D ’ AIDE INS PIRATOIRE INSUFFISANTE Se déclenche si, pendant 3 respirations consécutives, la pression maximale au masque atteint e entre l’inspiration et l’exp iration est <.
99 C ARACTERIS TIQUES F RANÇAIS T ableau 4 : Débit maximum à faible i mpédanc e aux pressi ons indiq uées V ARIATIO N DE PRESSION C OURBE V OLUME /P RESSIO N R EMARQUE Le fabr icant s e réserv e le droit de modifier ces car actéristi ques sans notifica tion préa lable.
100 G LOSSAI RE DES SYMB OL ES Lire le manuel d’utilisat ion avant emploi Appa reil de cla sse CF Interrupteur CA Classe II Informations concerna nt l’environnement DEEE 2002 /96/CE est une directive eur opéenne relative à l’élimina tion des déchets d’équipements éle ctriques et électroniq ues.
101 C ARACTERIS TIQUES F RANÇAIS G UIDE ET DECL ARATIO N DU FABRI CAN T — E MISS IONS ET IMMUNITE ELECTROMAGNET IQUES Guide et déc laration du fa bricant – Em issions électroma gnétiques L ’Aut oSet CS 2 est pr évu pou r une ut ilisa tion dan s l’e nviro nnemen t élec troma gnétiq ue déc rit ci -des sou s.
102 (suite page suivante) Guide et déclar ation du fabric ant – Immunité éle ctromagnéti que L ’AutoSet CS 2 est prévu pour une utilisation dans l’environnement é lectromagnétique décrit ci-dessous. Le cl ient ou l’utili sateur de l’Auto Set CS2 do it s’assu rer que celui-ci est util isé da ns un envi ronnem ent de ce type.
103 C ARACTERIS TIQUES F RANÇAIS Guide et décl aration du fa bricant – Immunité électromagné tique (suite ) L ’Au toSe t CS2 est prév u pour un e utili satio n dans l’ envir onnemen t élec tromag nétiq ue décr it ci-de ssous.
104 Distance s de séparation recomma ndées entre les équipeme nts de communicati on RF portables et mobiles et l’Auto Set CS2 L ’AutoSet CS2 est prévu pour une ut ilisation dans un environnement dans lequel l es perturbations radioélectriques par radiation sont contrôlées.
105 G ARANTIE LIMITEE F RANÇAIS G ARANTIE LIMI TEE ResMed garantit v otre produit ResMed contre t out défaut de matériaux et d e main- d’œuvre pour la pério de spécifiée ci-après à compter de l a date d’achat par le client d’origine. Cette gar antie n’est pas cessible.
106 fre.book Page 106 Friday, November 3, 2006 2:45 PM.
107 I NDEX F RANÇAIS I NDEX A alarme fuite imp ortante 87 panne de cour ant 86 pression élevée 86 alarme de fuite 81 alarmes menu 81 niveau de son 81 pression au masq ue basse 85 arrêt du traiteme.
108 S Smar t Da ta 82 SmartS top 81 T témoin d’alarme 77 touc he accès aux données réelles 77 déplacement vers le haut/bas 76 désactivation de l’alarme 77 , 85 droite 77 gauche 77 Marche /Arrêt 76 touche d’accès aux données réelles 83 tube cap teur de pression racc ordem ent 66 fre.
デバイスResMed AutoSet CS 2の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
ResMed AutoSet CS 2をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはResMed AutoSet CS 2の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。ResMed AutoSet CS 2の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。ResMed AutoSet CS 2で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
ResMed AutoSet CS 2を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はResMed AutoSet CS 2の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、ResMed AutoSet CS 2に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちResMed AutoSet CS 2デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。