® O WNERS MANUAL SPEAKER DISTRIBUTION SYSTEM.
Intr oduction 3 DS70 Features 3 Guided T our 4 Modes of Operation 5 Wiring Diagrams 6 Four-Zone 70V (Unbridged) 6 Two-Zone 70V (Bridged) 7 Four-Zone 25.
Intr oduction / DS70 Featur es Congratulations on purchasing the Samson DS70 Speaker Distribution System! The DS70 provides four high-quality toroidal step-up transformers in a single chassis. Each transformer can accept a nominal-level signal from any standard power amplifier, and can then convert it to a 70 volt, 25.
Guided T our 1: Channel inputs (1 - 4) - Connect output signal from a power amplifier to these four sets of binding post input connectors, making sure to follow the polarity markings silk-screened above each connector.
About Distributed Sound A distributed sound system (sometimes known as a “ constant voltage ” system) allows a single power amplifier to drive multiple loudspeakers over a single high-impedance line.
6 Four-Zone 70V (Unbridged) Wiring The illustration below shows the wiring for a single channel of a DS70 being used in standard 70 volt mode. In this kind of setup, the output level controls of the power amplifier can be used to control the volumes of each of the four zones.
7 The illustration below shows the wiring for two channels of a DS70 being used in Bridged 70 volt mode. Since the two input channels are bridged, a signal of up to 240 watts (into 8 ohms) can be received from the power amplifier.
CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN ! USE CLASS 2 WIRING AVIS; RISQUE DE CHOC ELECTRIQUE NE PAS OUVRIR DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE. emc EUR . USA . JPN BRIDGE OFF ON CH4 R CH3 R CH4 CH3 4 Ω 120W MAX. LOAD -++- CH2 L CH1 L -++- BRIDGE OFF ON SAMSON SERIAL NUMBER SERVO 4120 QUAD AMPLIFIER SAMSON TECHNOLOGIES CORP.
Two-Zone 100V (Bridged) Wiring The illustration below shows the wiring for a single channel of a DS70 being used in 100 volt mode. Because each transformer within the DS70 can deliver up to 70 volts, so to get a 100 volt output, two of the transformers have to be bridged (i.
Two-Zone 140V (Bridged) Wiring 10 The illustration below shows the wiring for a single channel of a DS70 being used in a non-standard 140 volt mode (which can be used with custom equipment where exceptionally long cable runs are required.
11 Note: The block diagram below shows the signal flow for a single channel of the DS70. Appendix A: Block Diagram Po w e r amplifier DS70 Speaker transf ormer Optional local s witcher and v olume con.
12 Specifications 1: Input Impedance 4 Ω (non-bridged modes) 8 Ω (bridged modes) 2 Ω (dual mode) 2: Maximum Power Each Input 120 Wrms (non-bridged modes) 240 Wrms (bridged and dual modes) 3: Output 70 V, 25.2 V (non-bridged), 100 V, 140 V (bridged) 4: Insertion Loss -0.
Produced by On The Right Wavelength for Samson Technologies Corp. Copyright 1998, Samson Technologies Corp. Printed January 1998 Samson Technologies Corp.
デバイスSamson DS70の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Samson DS70をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはSamson DS70の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Samson DS70の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Samson DS70で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Samson DS70を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はSamson DS70の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Samson DS70に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちSamson DS70デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。