Page 1 Model PRO 9549UG Installation Manual SELECT ABLE FEA TURES Note : The method of manual override can either be selected to operate from the valet switch or operate as custom code. Be certain to place a check mark indicating the method used in the box located on the last page of the owner's manual.
Page 2 INST ALLA TION OF MAJOR COMPONENTS Control Module : Select a mounitng location inside the passenger compartment ( up behind the dash ), and secure using the two screws provided. The control module can also be secured in place using cable ties. Do not mount the control module in the engine compartment, as it is not waterproof.
Page 3 When installing this system into vehicles with electronic “ after fans “, it is recommended you disable the voltage sense circuit. In voltage sensing applications, the closer to the battery that the red wire is connected, the less sensitive the voltage sense circuitry will be.
Page 4 Mini 10 Pin Edge Connector : Light Green Wire : ( - ) Instant T rigger Zone 1 This is an instant on ground trigger wire. This wire ( zone ) should be reserved for connection to optional ground output trigger devices such as motion and / or shock impact sensors.
Page 5 This wire provides an immediate ground signal, and stays at ground for up to 8 seconds as long as the button(s) on the keychain transmitter remain pressed. W ARNING ! Connecting the dark green w/ black trace wire to the high current switched output of trunk release circuits will damage the control module.
5 Wire Alternating Door Lock Circuits : In this application, it is necessary to cut the existing door lock by - pass wires. These wires run from the master door lock switch to the slave door lock switch, and then on to the door lock motors. Cut the existing lock wire, and connect the yellow wire to the slave switch or motor side of the cut wire.
Page 7 RED 87A 85 86 30 CUT TO IGNITION SWITCH TO START SOLENOID 87 TO +12 VDC IGN./CRANK EXISTING LOW CURRENT SOLENOID FEED WIRE (+12VDC, CRANKING ONLY) PRO 9549UG CONTROL MODULE ORANGE TRUNK.
PRO 9549UG CONTROL MODULE BLACK 2 STEP UNLOCK RELAY OUTPUTS To Relay Terminal #85 To Relay Terminal #86 LT. BLUE L.E.D. ZONE 1 Optional Negative Triggering Alarm Accessories LT.
デバイスAudiovox PRO 9549UGの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Audiovox PRO 9549UGをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはAudiovox PRO 9549UGの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Audiovox PRO 9549UGの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Audiovox PRO 9549UGで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Audiovox PRO 9549UGを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はAudiovox PRO 9549UGの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Audiovox PRO 9549UGに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちAudiovox PRO 9549UGデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。