CVW-EXA284 / CVW-EXA224 (H: 84 7/8”, L: 96 3/8”) / (H: 84 7/8”, L: 144 5/8”) MULTI-DECK FRESH PRODUCE CASES INSTALLATION & SERVICE MANUAL REMOTE TYPE DISPLAY CASE 2010 CVW-EXA184 / CVW-EXA.
2 Activity Safety Precautions In order to prevent any i njuries to person, equi pment and/or damage to the SANYO Cases, sections requi ring additi onal care to be undertaken will hav e one or all of t.
3 T ABLE OF C ONTENTS 1 SPECIFICAT IONS .................................................................................................................................................. 5 1.1 CVW-EXA284 / CVW-EXA224 ..................................
4 6 CARE AND CLEANING GUIDELINES ................................................................................................... .......... 21 6.1 E XTERIOR P ANELS (D AILY C LEANING ) ..............................................................
5 1 Specifications 1.1 CVW-EXA284 (H: 84 7/8”, L: 96 3/8”) / CVW-EXA224 (H: 84 7/8”, L: 144 5/8”) Model Name CVW-EXA284 CVW-EXA224 General Application: Medium Temperature (Fresh Produce) Medium Temperature (Fresh Produce) Cooling Capacity: 1224 BTU/h/ft.
6 1.2 CVW-EXA184 (H: 80 7/8”, L: 96 3/8”) / CVW-EXA124 (H: 80 7/8”, L: 144 5/8”) Model Name CVW-EXA184 CVW-EXA124 General Application: Medium Temperature (Fresh Produce) Medium Temperature (Fresh produce) Cooling Capacity: 1146 BTU/h/ft. ( 2682W ) 1146 BTU/h/ft.
2 Dimensions 2.1 External Dimensions 2.2 Footprint ① Waste Outlet ② Electrical Connection ③ Refrigeration Outlet * Dimensions given in inches and millimeters (mm in parentheses).
2.3 External Dimensions 2.4 Footprint * Dimensions given in inches and millimeters (mm in parentheses). CVW-EXA184 / CVW-EXA124 ① W a s t e O u t l e t ② E l e c t r i c a l C o n n e c t i o n .
9 3 Unloading and Carpentry P rocedures 3.1 NSF Certification The SANYO Cases described in this manual are built to meet the requirements of American Nation al Standard/NSF International Standard 7.
10 3.5 Aligning Cases WARNING SANYO Cases are heavy and bulky, an d require at least two people for unloading, mov ing, and inst allation. Do not walk on the top of the SANYO Case s. Walking on the top of the SANYO Case may lead to serious injury and/or damage to the SANYO Case.
11 3.7 Joining Instructions 3.7.1 Applying gasket (for connecting cases or installing side panels). ① Make sure that all SANYO Cases are resting level. ② Make sure that all required parts for joining are present (gasket, bolts, joint covers, nuts, etc.
12 3.7.2 Connecting cases. ① Apply gasket as described above. ② Connect cases by using the attached bolts, joint covers, and nuts. Silicone seal Note: Gasket ends that are open must be sealed off by applying silicone at the installation site. Note: Connection point must be silicone sealed.
13 3.8 Installing Patch Ends 1. Apply gasket to case body (per previo us inst ructions). 2. If present, remove protective film from inside wall of Patch End. 3. Place Patch End to line up with bolt holes. 4. From inside unit ratchet in M8 & op tional M5 bolt into Patch End until secure.
14 3.9 Installing Kickplate 1. Align the mounting hole in the Kickplate with the sl ot in the Kickplate Mounting Bracket on the SANYO Case and tighten accordingly.
15 3.10 Installing Handrail and Bumper Attaching the Bumper 1. Attach Maintenance Bumper (length 39-3/8 inches ) to Bumper Brackets over the electrical connection box (“Raceway”) on each SANYO Case. Th e Raceway is located on the right end of each SANYO Case.
16 4 R efrigeration, Plumbing & Electrical P rocedures 4.1 Piping (Plumbing, Refrigeration) ● U-trap installation Install U-trap referring to the drawing below.
17 4.2 Electrical Data Please refer to Specifications sectio n and nameplate attached to merchand iser for electrical information. 4.3 Electrical – Guidelines & Precautions All wiring and electrical field wo rk must comply with the National Electrical Co de (“NEC”) and other applicable local codes.
18 4.4.2 Wiring Diagram CVW-EXA284/184 C VW-EXA224 / 124.
19 5 Operation 5.1 Load Limits In order to maintain proper temperatur e and unit performance, the Dual Air Curt ains in each SANYO Case must remain unobstructed: Do not stock shelves beyond the marked load limits. Do not block Honeycombs or Return Air Grilles.
20 Installing FDA/NSF Thermometer Suggested locations for the thermometer re quired by NSF/ANSI 7 and the FDA Food Code are indicated above. It is the respon sibility of the Purchaser/End User of the SANYO Case to determine the location wi th in the food storage area that best meets these code requirements.
21 6 Care and Cleaning Guidelines In order to keep SANYO Cases sanitary and in good working order, we recommend thorough periodic cleaning as follows: 6.1 Exterior Panels (Daily Cleaning) a. Exterior panels should be cleaned wi th water only. Wet a soft cloth and wring it out to wip e down panels.
22 Please make sure to check and clean the drain trap at least once a month. Remove any material that has gathered in the drain trap and dispose of it.
23 7 Service 7.1 Replacing Fan Motors and Blades HAND PROTECTION REQUIRED! Activities to be undertaken require finger and palm protection to prevent personal injuries. To replace the fan motors: ① Remove the outer Air Curtain Duct Cover and socket covers.
24 For models with Standard-type (AC) Fan Motors: CVW-EXA124/224 CVW-EXA184/284 No. Part Name Model Part Number Quantity Quantity Hex Nut - HN44162520U18 5 3 Spring Washer - SW49266225U18 5 3 ① -a .
25 For models with high-efficiency-type (DC) fan motors: CVW-EXA124/224 CVW-EXA184/284 No. Part Name Model Part Number Quantity Quantity Hex Nut - HN44162520U18 5 3 Spring Washer - SW49266225U18 5 3 .
26 7.2 Replacing Electronic Ballasts CVW-EXA124/224 CVW-EXA184/284 Type Model Part Number Quantity used Quantity used 3-lamp QHE3X32T8/UNV ISN-SC-1-CC-B 8FC05400000301 2 - 2-lamp QHE2X32T8/UNV ISN-SC-.
27 7.3 Replacing Fluorescent Lamps The unit comes with covers placed over each fluorescent lamp. Ensure that these covers are placed over the new lamps before reinstallation. LAMP END CAP CAUTION! Always use Sanyo lamp covers and end caps wh en replacing lamp covers and end caps.
28 7.3 Expansion Valve D a n f o s s MODEL Valve Body P.N. Body Type Refrig erant Valve Orifice P.N. Orifice Type 9FT2450000110 TUAE 068U2287 R404A 9FT2450000100 TU7 068U1037 CVW-EXA124 CVW-EXA224 9FT.
29.
SANYO E & E Corporation 2001 Sanyo Avenue, San Diego, CA 92154-6229 USA Toll Free USA 800-95-SANYO (72696) · Fax 619-661-4183 http://us.sanyo.com/Food-Solutions Manufactured and Distributed by: MCVW V01.
デバイスSanyo CVW-EXA224の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Sanyo CVW-EXA224をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはSanyo CVW-EXA224の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Sanyo CVW-EXA224の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Sanyo CVW-EXA224で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Sanyo CVW-EXA224を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はSanyo CVW-EXA224の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Sanyo CVW-EXA224に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちSanyo CVW-EXA224デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。