Searsメーカー005735-0の使用説明書/サービス説明書
ページ先へ移動 of 22
Owner ’s Manual • SAFETY • AS SEMBL Y • OPER A TION • TROUBLESHOOTING • W ARR ANTY www .generac.com or 1-888-436-3722 AUTHORIZED DEALER SUPPORT : GP Series P or table Generator COMMERCIAL .
T able of Contents OWNER'S MANUAL Introduction ..............................................................................1 Read This Manual Thoroughly .................................................1 Safety Rules ...........................
INTRODUCTION Thank you for purchasing this model by Generac P ower Systems, Inc. ® This model is a compact, high per for mance, air -cooled, engine driven generator designed to supply electrical power to operate electrical loads where no utility power is available or in place of utility due to a power outage.
2 Never star t or stop the unit with electrical loads connected to • receptacles AND with connected devices turned ON. Star t the engine and let it stabilize before connecting electrical loads. Disconnect all electrical loads before shutting down the generator .
ELECTRICAL HAZARDS All generators covered by this manual produce dangerous electrical • voltages and can cause fatal electrical shock. Utility power delivers extremely high and dangerous voltages as does the generator when it is in operation.
4 1.1 UNP ACKING Set the palleted car ton on a rigid flat sur face. • Remove staples along bottom of car ton that fasten car ton to pallet. • Open car ton from top. Remove all packaging material. • Remove separate accessory box. • Lif t car ton off the generator .
5 5 1.2.3 BA TTERY CONNECTION The batter y shipped with the generator has been provided fully charged. • Caution must be taken when connecting the batter y . NOTE: A battery may lose some of it’s charge when not in use for prolonged periods of time.
6 6 Section 2 – Operation 2.1 KNOW THE GENERA TOR Read the Owner ’s Manual and Safety Rules before operating this generator . Compare the generator to Figures 4 through 6 to become familiarized with the locations of various controls and adjustments.
7 2.2 HOURMETER The Hourmeter tracks hours of operation for scheduled maintenance: There will be a one time break in "CHG OIL" message that flashes with the elapsed time in hours and tenths af ter the first 30 hours of operation.
8 2.3.3 120 VAC, 30 AMP RECEPT ACLE Use a NEMA L5-30 plug with this receptacle. Connect a 3-wire cord set rated for 125 V olts AC at 30 Amps (or greater) to the plug (Figure 9). Figure 9 - 120 VAC, 30 Amp Receptacle Use this receptacle to operate 120 V olt AC, 60 Hz, single phase loads requiring up to 3600 watts (3.
9 Figure 13 - Grounding the Generator Proper grounding of the generator will help prevent electrical shock in the event of a ground fault condition in the generator or in connected electrical devices. Proper grounding also helps dissipate static electricity , which of ten builds up in ungrounded devices.
10 10 Section 2 – Operation *T able Saw (10") . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1750 to 2000 T elevision . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .200 to 500 T oaster . . . . . . . . . . . .
11 Open the fuel shut-off valve (Figure 15). • Figure 15 - F uel Shut-off Valve Locate the Idle Control ON/OFF switch on the control panel and set it • to the “OFF” position (Figure 16). Figure 16 - Idle Control Switch Move engine CHOKE knob outward to • “Full Choke” position (Figure 17).
12 2.12.1 INITIAL ST ART -UP A delay built into the low oil shutdown system allows oil pressure to build during star ting. The delay allows the engine to r un for about 10 seconds before sensing oil pressure. 2.12.2 SENSING L OW OIL PRESSURE If the system senses low oil pressure during operation, the engine shuts down.
13 13 Section 3 — Maintenance 3.2.2 ENGINE SPECIFIC ATIONS Rated Horsepower @ 3600 RPM 30 Displacement 992cc Spark Plug T ype Champion RC14Y C or Equivalent Spark Plug Gap 0.040 inch or (1.01 mm) Gasoline Capacity 16 U.S. gallons Oil T ype Summer – SAE 30, Winter – 5W-30 Synthetic or 10W -30 Oil Capacity w/ Filter Change = 1.
14 14 Section 3 — Maintenance 3.3.6 REPLACING THE SP ARK PLUGS Use Champion RC14Y C spark plug or equivalent. The correct air gap is 1.01 mm (0.040 in.). Replace the plugs once each year . This will help the engine star t easier and r un better . 1.
15 15 3.6 ADJUSTING V AL VE CLEARANCE After the first 50 hours of operation, check the valve clearance in the engine and adjust if necessary . Important: If feeling uncomfor table about doing this procedure or the proper tools are not available, please take the generator to the nearest ser vice center to have the valve clearance adjusted.
16 Avoid spray from spark plug holes when cranking engine. Install and tighten spark plugs. Do not connect spark plug wires. • Clean the generator outer sur faces. Check that cooling air slots and • openings on generator are open and unobstr ucted.
17 17 Section 4 — T roubleshooting 4.1 TROUBLESHOOTING GUIDE PROBLEM CAUSE CORRECTION Engine is running, but no AC output is available. 1. Circuit breaker is open. 2. P oor connection or defective cord set. 3. Connected device is bad. 4. Fault in generator .
18 CALIFORNIA EMISSION CONTROL WARRANTY ST ATEMENT YOUR W ARRANTY RIGHTS AND OBLIGATIONS The California Air Resources Board (CARB) and Generac P ower Systems, Inc. (Generac) are pleased to explain the Emission Control System warranty on your new engine.
19 Section 5 – W arranty EMISSION CONTROL SYSTEM WARRANTY Emission Control System Warranty (ECS warranty) for 2001 and later model year LSI engines: (a) Applicability: This warranty shall apply to 2001 and later model year engines.
Section 5 – W arranty P ar t No. 0H0676 Rev . B (02/18/09) Printed in U.S.A. GENERAC POWER SYSTEMS “TWO YEAR” LIMITED WARRANTY FOR GP SERIES PORT ABLE GENERATORS For a period of two years from the date of original sale, Generac P ower Systems, Inc.
デバイスSears 005735-0の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Sears 005735-0をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはSears 005735-0の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Sears 005735-0の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Sears 005735-0で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Sears 005735-0を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はSears 005735-0の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Sears 005735-0に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちSears 005735-0デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。