Kenmore 1700 11 GALLON CENTRAL HUMIDIFIER Installation Maintenance Repair Parts Troubleshooting Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A.
contents WARRANTY ........................................... 2 BEFORE YOU START Rules for Safe Installation and Operation ................................... 2 Tools and Materials Needed .................. 2 UNDERSTANDING HUMIDITY .............. 3 SELECTING A LOCATION .
THANK YOU? Thank you for selecting a Sears Humidifier. It will provide years of service if you give it a little care, UNDERSTANDING HUMIDITY Humidity can be puzzling, it cannot be seen, heard, touched, smelled or tasted. Many people do not understand what a humidi- fier will or will not do.
selecting a location Consider these points as you choose the location for your hu- midifier. Locate humidifier on supply air plenum (Fig. 1) or return air plenum. If the humidifier is installed on the return air plenum, the flexible hose, round opening, is connected to the supply air plenum.
Motor Bracket _ B Install motor bracket on left side. Make sure bracket is firmly seated (Fig. 6). Nylon Lance C Install wire support and nylon bearing in lances. Be sure groove in nylon bearing is toward inside of humidifier. Bend that portion of the wire support leg ex- tending below the lance, outward, to lock support in lances (Fig.
Top Humidifier Plenum---> _.5" Minimum Clearance O o -Drill (3) Holes 1/8" Dia. - Cut Opening • Level Line & Bottom of Humidifier 2 Mount the humidifier to the hot air plenum using the three screws provided. Bend the two tabs 180 ° inward to seal the humidifier to the Plenum (Fig.
Turn handle clockwise until it has pierced the water line and valve is completely closed (Fig. 16). , _ Partially uncoil the tubing. Slide the brass compres- sion nut over the tubing. The threads in the nut must face the tubing end. Place the brass compression sleeve as shown in Fig.
humidistat The humidistat is designed to mount on the cold air plenum of your furnace or on an interior wall of the home. The cold air ple- num, however is the preferred location for sensing the average humidity throughout your home. Select your location and follow the appropriate instructions.
Mountin( Screws (4) Cover-_ Hole In Wall Mounting Screws Wall Mount )_--Spacers Control Unit Humidifier Spade _ Terminals f Wall Outlet I NOTE: Make sure wall outlet is not controlled by a switch. I operation 1 Set knob to the lowest temperature predicted for a 24-hour period.
12. Close top metal hinged cover and replace front plastic cover. 13. Plug in transformer. 14. Turn humidistat to "test" momentarily and check for media wheel rotation. Reset humidistat according to outdoor tem- perature as instructed on label and reinstall front cover.
repair parts KENMORE "1700" CENTRAL HUMIDIFIER MODEL NO. 303.14601 I I I I I / KEY PART KEY PART NO. NO. DESCRIPTION NO. NO. DESCRIPTION 1 43134913 2 43160803 3 21605701 4 40437001 5 4400650.
Kenmore 303.14601 FURNACE HUMIDIFIER MAINTENANCE NOTE: APPLY THIS LABEL WHERE IT WILL BE EASILY SEEN AND SERVE AS A REMINDER TO PERFORM THIS ROUTINE SERVICE. Regular cleaning is necessary to keep the parts free of lime deposits. Service every month during the heating season or more often depending on the water conditions.
Kenmore 1700 11 GALLON CENTRAL HUMIDIFIER For the repair or replacement parts you need Call 7:00 a.m. - 7:00 p.m., 7 days a week 1-800-366-PART (1-800-366-7278) For in-home major brand repair service .
デバイスSears KENMORE 1700の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Sears KENMORE 1700をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはSears KENMORE 1700の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Sears KENMORE 1700の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Sears KENMORE 1700で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Sears KENMORE 1700を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はSears KENMORE 1700の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Sears KENMORE 1700に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちSears KENMORE 1700デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。