SherwoodメーカーSRB5900の使用説明書/サービス説明書
ページ先へ移動 of 29
As sembly & Maintenanc e Guide (SRB53 00) (SRB5900) (SRB5700) (SRB5100) ® ™ ® REGUL A T ORS ® ®.
FIRS T ST AGE - OA SIS™ SRB5700, BLIZZARD™ SRB5900, MAGNUM® SRB5300, BRUT™ SRB5100 T o determine the first stage of a particular regulator , compare the r egulator with the pictures and diagrams in this guide. The model number of the regulator is laser stamped on the first stage between two of the outlet ports.
T ABLE OF CONTENTS Page 1.0 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 2.0 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 2.1 SRB5700 (Oasis), SRB5900 (Blizzard), SRB5300 (Magnum) .
1 1.0 INTRODUCTION 1. The procedur es in this manual apply to the Sherwood Scuba SRB5900 Blizzard, SRB5700 Oasis, SRB5300 Magnum and SRB5100 Brut regulators only . The older SRB3900 Blizzard, SRB3700 Oasis, SRB3300 Magnum and SRB2100 Brut regulators have dif ferent part and service procedur es.
6. Companion instructional VHS videotapes to this and other Sherwood Scuba repair manuals ar e available from Sherwood Scuba at a nominal cost. Ask your Sherwood Scuba Sales Representative for details. 7. If you have any questions, or need more information, contact your Sherwood Scuba Sales Representative or Sherwood Scuba Customer Service.
2.0 SPECIFICA TIONS 2.1 SPECIFICA TIONS FOR THE SRB5900 BLIZZARD, SRB5700 OASIS, AND SRB5300 MAGNUM REGULA TOR MODEL: Sherwood SRB5900 Blizzard, SRB5700 Oasis, SRB5300 Magnum AIR FLOW: 33 cu. ft. (935 liters)/min. @ 1 atmosphere INHALA TION RESIST ANCE: .
2. 2 SPECIFICA TIONS FOR THE SRB5100 BRUT REGUL A T OR REGULA TOR MODEL: Sherwood SRB5100 Brut AIR FLOW: 30 cu. ft. (850 liters)/min. @ 1 atmosphere INHALA TION RESIST ANCE: 1" (2.5 cm) w .c @ 1 atmosphere EXHALA TION RESIST ANCE: 0.7" (1.8 cm) w .
3.0 O-RINGS REFERENCE CHART 1. Before you begin disassembly of the r egulator , test the first and second stages for output pressur es and leakage. Pre-testing in this way will help the technician to pinpoint any specific problems r equiring repair . 2.
4 .0 FIRS T S T AGE PROCEDURE S 4 .1 T OOLS REQUIRED FOR FIRS T S TAGE SERVICING – Bench vise – 3/32" Allen wrench – 5/32" Allen wrench – 6" or 8" adjustable wrenches – 1.
4. Install a Sherwood regulator support handle (p/n TL113) into one of the low-pr essure ports. Use the support handle and a 15" adjustable wrench or bench vise to loosen the yoke nut fr om the body . See Photo #1. 5. Remove the yoke and yoke nut from the body .
11. Use a pocket screw driver to r emove the black washer that was beneath the element assembly . Save this washer as it can usually be reused. Be car eful not to scratch the metal surface under the washer . 12. Use a pocket screwdriver to r emove the retaining ring or star washer that holds the inlet filter in place.
The sealing surface on the body where the one-way valve seals must be totally clean of deposits. If any deposits remain on the sealing surface after initial cleaning, take a fine abrasive polishing stick or a pencil with a new eraser and polish the surface to remove deposits (see Photo #3).
4 .3 ASSEMBL Y OF FIRS T S T AGE 1. The part number for each regulator kit can be found in Sherwood ’ s T ools, Repair Kit and Accessories – Assembly & Maintenance Guide . The kits contain the parts that are always replaced at every annual service interval.
16. If the first stage has a SAA-5300 DIN adapter installed instead of a standard yoke, see the installation instructions given in Sherwood T echnical Bulletin #104 for overhaul and installation instructions of the DIN adapter . 4 .4 TES TING OF FIRST S T AGE A .
C. Intermediate Pr e ssur e T e st 1. Attach any Sherwood second stage to one of the low pressur e ports, and the Sherwood intermediate pressur e gauge (p/n TL119) to another low pressure port.
13 5.0 SECOND S T AGE PROCEDURES 5.1 T OOLS REQUIRED FOR SECOND S TAGE SERVICING – T wo good quality 6" or 8" (15 or 20 cm) adjustable wrenches – #10 T orx screwdriver – Side cutting p.
9. Use the Sherwood in-line adjusting tool (p/n TL102) to back the adjusting orifice out of the orifice housing until the threads disengage. Remove the in-line adjusting tool, and push the adjusting orifice the rest of the way out of the orifice housing with the Sherwood Plastic Pr obe (p/n TL111).
corrosion. Corr osion or minor scratches can be polished out using a fine-grit rubberized polishing stick or a clean new pencil eraser . Do not apply heavy pressure when r otating the polishing stick. Stop polishing immediately after the corrosion or scratch disappears.
8. Tighten the screws using a # 10 T orx screw driver just enough to seat them snugly . There is no reason to turn these screws beyond the first contact point. Do not overtighten . This scr ew is threading into plastic, which will hold well in service but is easily stripped if overtightened.
7. Look across the case and gauge tool. The tip of the lever should be even with the bottom surface of the gauge. If you are r e-using the same major parts of the regulator , this measurement will most likely be corr ect, and no adjustment will be needed.
11. Replace the diaphragm. Continue to test the gap between the lever and the diaphragm after each bending until the lever is in the correct position. 12. Return to Section 5.3.4 of this manual to complete assembly of the regulator . 5.5 TES TING OF SECOND S T AGE A .
D. External Air Leaks 1. Attach the regulator first stage to a tank short enough to totally submer ge the first and second stage in your filling station cooling water . 2. With the tank valve still turned off, flood the second stage completely with water , and then position it mouthpiece up.
6.0 HELPFUL HINTS 6.1 TROUBLESHOO TING REGUL A TORS POSSIBLE CAUSE RECOMMENDED ACTION A . High Inhalation Effort at Depth: 1. Inlet filter clogged. Replace the filter . 2. No air flowing through the dry air bleed system. Check the flow rate coming out of the one-way bleed valve .
C. W et Breathing: 1. Improper clearing, or diver diving in total Instruct the diver on proper clearing head-down position. technique. 2. Diaphragm improperly installed. Visually check position of diaphragm. 3. Hole in the mouthpiece at tie area. Replace the mouthpiece.
6. 2 PARTS CLEANING RECOMMENDA TIONS Regulators which see heavy use, particularly those used in salt water , often require extra ef fort to remove dirt and corr osion from the parts of the regulator . Some suggested cleaning solutions are listed at the end of this section, and ther e are probably many others being used successfully .
mounting the regulator on the tank valve. Slide the hose pr otectors back to inspect the areas of the hose normally covered. Be sur e all hose connections are tight. 2. Before turning on the tank air valve, check to make sure that the yoke nut or DIN connection is tight and the regulator body is aligned pr operly , with no kinks in the hoses.
7 .0 TWO YEAR WARRANTY AND MAINTENANCE INFORMA TION 7 .1 PROPER PROCEDURE FOR WARRANTY PAPERWORK 1. For detailed information on the operation of the Sherwood Scuba T wo Y ear Limited Warranty , please refer to Sherwood Scuba T echnical Bulletin #112. Y ou can also contact Sherwood Customer Service if you still have questions about the warranty .
ITEM # CA T ALOG # DESCRIPTION 1 . . . . . . . . . . . . .5100-7WH . . . . . . . . . . . . . Label Insert for the Brut 1 . . . . . . . . . . . . .5300-7WH . . . . . . . . . . . . . Label Insert for the Magnum 1 . . . . . . . . . . . . .5700-7Y . . . .
Printed in the U.S.A on recycled paper Part Number S-MAN2004 Sherwood Scuba, the SS symbol, Oasis, Blizzard, Magnum, Brut and Wisdom are trademarks of Sherwood, Harsco Corporation Gas and Fluid Control Gr oup. All other names are trademarks of their respective owners.
デバイスSherwood SRB5900の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Sherwood SRB5900をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはSherwood SRB5900の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Sherwood SRB5900の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Sherwood SRB5900で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Sherwood SRB5900を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はSherwood SRB5900の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Sherwood SRB5900に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちSherwood SRB5900デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。