Documentat ion Number FBDA0797 M anual Cover Page B&B Electronics -- P O Box 1040 -- Ottaw a, IL 61350 PH (815) 433-5100 -- FA X (815) 433-5105 Strain Gauge/Load Cell Bridge Amplifier Model FBDA D.
Documentat i on Num ber FBDA0797 Manual Table of Content s i B&B Electronics -- P O Box 1040 -- Ottaw a, IL 61350 PH (815) 433-5100 -- FA X (815) 433-5105 TABLE OF CONTENTS CHAPTER 1: INTRODUCTION...................................................
Documentat ion Number FBDA0797 M anual 1 B&B Electronics -- P O Box 1040 -- Ottaw a, IL 61350 PH (815) 433-5100 -- FA X (815) 433-5105 Chapter 1: Intr oduction Features The FBDA is a s ignal conditioning module that allows you to measure voltages produced by full- bridge sensor s using a data acquisition module.
2 Documentation Number FBDA 0797 M anual B&B Electronics -- P O Box 1040 -- Ottaw a, IL 61350 PH (815) 433-5100 -- FA X (815) 433-5105 Packing List Examine the shipping ca rton and the contents for physical damage. The following items should be in the s hipping carton: 1.
Documentat ion Number FBDA0797 M anual 3 B&B Electronics -- P O Box 1040 -- Ottaw a, IL 61350 PH (815) 433-5100 -- FA X (815) 433-5105 Chapter 2: Connections Power Supply Connections The FBDA module requires 13 to 18VDC @ 10mA. Model 232PS2 available from B&B Electr onics is recommended.
4 Documentation Number FBDA 0797 M anual B&B Electronics -- P O Box 1040 -- Ottaw a, IL 61350 PH (815) 433-5100 -- FA X (815) 433-5105 Data Acquisition Connec tions The connections to the Data Acquisition Module are made through a DB-25 (male) connector.
Documentat ion Number FBDA0797 M anual 5 B&B Electronics -- P O Box 1040 -- Ottaw a, IL 61350 PH (815) 433-5100 -- FA X (815) 433-5105 Figure 2.1: Block Di agram of FBDA Connecti ons A / D Note: C.
Documentat ion Number FBDA0797 M anual 7 B&B Electronics -- P O Box 1040 -- Ottaw a, IL 61350 PH (815) 433-5100 -- FA X (815) 433-5105 Chapter 3: Gain Selection The FBDA has sev eral different gain settings to provide the largest poss ible voltage range for an A/D conv erter.
8 Documentation Number FBDA 0797 M anual B&B Electronics -- P O Box 1040 -- Ottaw a, IL 61350 PH (815) 433-5100 -- FA X (815) 433-5105 Sensors that inc orporate bridge c ircuitry usually have noticeable zero offs ets. This s hould be considered when tak ing measurements and deter mining gain.
Documentat ion Number FBDA0797 M anual 9 B&B Electronics -- P O Box 1040 -- Ottaw a, IL 61350 PH (815) 433-5100 -- FA X (815) 433-5105 Chapter 4: Excitation V o ltage Sensors that ar e based on a Wheatstone bridge need an excitation voltage to ex cite the bridge.
デバイスB&B Electronics FBDAの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
B&B Electronics FBDAをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはB&B Electronics FBDAの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。B&B Electronics FBDAの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。B&B Electronics FBDAで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
B&B Electronics FBDAを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はB&B Electronics FBDAの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、B&B Electronics FBDAに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちB&B Electronics FBDAデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。