Baldorメーカー3KW-9KWの使用説明書/サービス説明書
ページ先へ移動 of 36
OPERATOR'S MANUAL FOR YOUR PREMIER POW’R PRODUCTS GENERATORS OHV Series 3KW-9KW BALDOR GENERATORS 3815 Oregon. Street • Oshkosh WI 54902 Telephone 236-4200 • Fax 920-236-4219 FORM#: S-PSG-0.
FORWARD This manual contains the information you need to safely and efficiently operate your generator set. During the preparation of this manual every effort was made to ensure the accuracy of its contents.
♦ Place protective covers and gu ards over the rotating parts, if rotating parts such as the drive shaft, pulley, belt, etc. are left exposed, they are potentially hazardous. ♦ When cleaning, repairing or in specting, make sure all moving parts h ave stopped.
♦ Know how to stop the engine quickly and und erstan d the operation of all controls. ♦ Never permit anyone to operate the genera tor set without proper instruction s.
♦ Always treat the electrical circui ts as if they were energi zed. ♦ Disconnect all leads plugged into the unit Prior to worki ng on it. ♦ Have the electrical circuits se rviced only by qualified technicians. ♦ Inspect wiring frequently and replace frayed, broken or poor leads.
○ ○ ○ ○ FOR GASOLINE OR DIESEL POWERED GENERATOR SETS ○ ○ ○ ○ ♦ Check all fuel supply piping and thei r connec tions on a monthly basis for fuel leaks. ♦ Use only approved piping and componentry in your fuel supply system. ♦ A professional, experience d technician should only install the fuel supply system.
TABLE OF CONTENTS SECTION PAGE Basic Location Information…………………………………………………………………………………………………..1 Basic Connection Information…………………………………………………………………………………………….
LOCATION For best service from your statio nary generator set there are several factors which should be taken into consideration when choosi ng the best location in wh ich to permanently mount it: MOISTURE: All ele ctrical equipment shoul d be protected from ex cessive moisture.
CONNECTIONS WIRING: Use sufficiently large insu lated wire to connect the generator set to the load. The gauge of the wire will depend largely on the distance, the pe rmissible voltage drop, and the size and type of load. If you are not sure of the gaug e wire needed for your application, consult a competent electrician.
ENGINE INFORMATION This operator's manual only covers basic day-to-d ay engine operating inst ructions. However, the engine manufacturer's manual is includ ed with your generator s et and should be referred to for any additional information you may need.
MAINTENANCE MAINTENANCE SHOULD ONLY BE PERFORMED ON THE GENERATOR SET AFTER THE ENGINE HAS STOPPED AN D THE GENERA TOR SET HAS COOLED DOWN. THE BATTERY AND SPARK PLU G SHOULD ALSO BE DISCONNECTED PRIOR TO PERFORMING MAINTENANC E.
equipped with this feature) . Make sure that the auto idl er magnet does not touch th e throttle lever of the engine when it is ru nni ng and the auto idler switch is turned off. √ Adjust the engine s peed to 3720 RPM's (62 Hz) with no load applied to the generator set.
STORAGE If you will not be using the generato r set for a si gnificant amount of time (3 months or longer) you should store the generator to pr event any problems th at coul d arise from sitting idle. Please fully read the following guidelines pr ior to storing the unit.
USE OF ELECTRIC MOTORS Electric motors require much more current (am peres ) to start them than to run them. Some m otors, particularly split-phase motors are very difficult to start and requires 5 to 7 times as much cur rent to start them as it does to run them.
ORDERING PARTS When Generator repair parts are ne eded, they may be obtained by calling the Parts Department at Baldor Generators or the nearest local office of Bald or Electric C ompany. Accurate information such as the following will assure that you receive accu rate parts for your particular generator: 1.
OPERATION PRIOR TO STARTING THE UNIT: 1. Locate and set up the generator set in an open, dry, well ventilated and reasonably level location. OPERATING THIS UNIT IN AN AREA NOT SUITABLE FOR IT'S PROPER USE MAY CAUSE DAMAGE TO THE UNIT, SEVERE INJURY, OR DEATH.
If the engin e does not start after tur ning the engine over a few times, smell for fuel n ear the air cleaner. If there is a sig nificant gasoline smell coming from the air cleaner, turn the choke lev er off and attempt to s tart the engine with the choke off.
SIMPLE TROUBLESHOOTING Listed below are the mor e simple solutions to some of th e more co mmon problems that are reported to the Service D epartment at Baldor Gen erators. These troublesho oting solutions are meant to be an aid for a person who has minimal electrical knowledge an d experience.
E. Restart the unit and ch eck for voltage output. BE EXTREMELY CAREFUL WHEN US ING THE ALTERNATE METHOD FOR FLASHING THE GENERATOR AS YOU WILL BE WORKING AROU ND FAST, ROTATING COMPONENTS ALONG WITH LIVE WIRES AND BARE CONNECTIONS. LOW VOLTAGE OUTPUT Possible Problems: 1.
CONTROL PANEL For OHV30 A = NEMA 515R GFCI D UPLEX. This receptacle is a gr ound fault circuit i nterrupter duplex rated at 20 amps. This receptacl e must be tested on a regular basis (monthly). B = STANDARD DUPLEX RECEPTACLE. This is your st andar d household duplex receptacle, it is rated for 120 VAC, 15 Amps.
CONTROL PANEL FOR OHV40, OHV50, OHV60 A = NEMA 515R GFCI DUPLEX. This ground fault circuit interrupter duplex is rated at 125VAC , 20 Amps. This receptacle must be tested on a regular basis (Monthly). B = AC Circuit Breakers. These Circuit Brea kers provide overload protecti on for the generator set.
CONTROL PANEL F O R O H V 8 5 A = THE AUTO IDLER FEATURE ON/OFF SWITCH. Th e Auto Idler Feature a llows the engine on the generator set to slow down t o a "slow speed position" when there is no l oad being applied to the unit.
Generator-End Componentry OHV30 Genset - 16 -.
PARTS BREAKDOWN FOR OHV30 GENERATOR SETS: REF LETTER OLD PART # NEW PART # DESCRIPTION A 46.10025C 61SA0019A01 Stator assembly B 66.00025 61RA0011A00 Rotor Assembly D 230.02020 10XN3124K12 Bolt to attach Rotor E 230.04020 10XN3124Y14 Bolt to Attach Engine Adaptor F 230.
Generator-End Componentry OHV40, OHV50, OHV60 Control Box Componentry OHV40, OHV50, OHV60 - 18 -.
PARTS BREAKDOWN FOR OHV40, OHV50, OHV60 GENERATOR SETS: REF LETTER OLD PART # NEW PART # DESCRIPTION A 46.00045D 61SA0010A02 Stator asse mbly for 4000 to 5000 Watt Units A 46.00055B 61SA0013A00 Stator assembly for 6000 Watt Units B 66.00045 61RA0013A00 Rotor Assemb ly for 4000 to 5000 Watt Units B 66.
Generator-End Componentry OHV85 Control Box Componentry OHV85 - 20 -.
PARTS BREAKDOWN FOR OHV85 GENERATOR SETS: REF LETTER OLD PART # NEW PART # DESCRIPTION A 46.10075B 61SA0022A01 Stator assembly B 66.00075 61RA0016A00 Rotor Assembly C 140.00200 CT0046A00SP Idler Transformer D 230.04040 Consult Factory Bolt to atta ch Rotor ***** E 230.
Wiring Diagram OHV30 - 22 -.
Wiring Diagram OHV40, OHV50, OHV60 - 23 -.
Wiring Diagram OHV85E - 24 -.
.
LIMITED WARRANTY Effective Au gust 1, 2003 Unless otherwise provided, Baldor generators are warrant ed agains t defects in Baldor workmanship and materials for a period of time as set forth in the Warranty Period chart below.
*Labor coverage for warra ntable repairs is provide d for the app licable period not to exceed published rates as contained in the Baldor Generators Warranty Policy. Mileage is a llowe d only for permanent installations not to exceed published rates as contained in the Baldor Generators Warra nty Policy.
CALIFORNIA PROPOSITION 65 WARNING Engine exhaust from th is product contains chemicals known to the state of California to cause cancer, birth defects, and other reproductive harm.
Service is just a phone call away: 800-872-7697 www.baldor.com/products/generators.asp 3815 Oregon Street Oshkosh WI 54902 Phone: (920) 236-4200 Fax: (920) 236-4219.
デバイスBaldor 3KW-9KWの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Baldor 3KW-9KWをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはBaldor 3KW-9KWの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Baldor 3KW-9KWの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Baldor 3KW-9KWで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Baldor 3KW-9KWを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はBaldor 3KW-9KWの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Baldor 3KW-9KWに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちBaldor 3KW-9KWデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。