A+ SER VER 1022G-URF S UPER ® USER’S MANUAL Revision1.0e.
A+ Server 1022G-URF User's Guide ii Manual Revision 1.0e Release Date: March 06, 2014 The information in this User ’s Manual has been carefully reviewed and is believed to be accurate.
iii Preface Preface About This Manual This manual is written for professional system integrators and PC technicians. It provides information for the installation and use of the A+ SERVER 1022G-URF . Installation and maintenance should be performed by experienced technicians only .
A+ Server 1022G-URF User's Guide iv Chapter 5: Advanced Serverboard Setup This chapter provides detailed information on the H8DGU-F serverboard, including the locations and functions of connectors, headers and jumpers. Refer to this chap - ter when adding or removing processors or main memory and when reconguring the serverboard.
v Preface Contents Chapter 1 Introduction 1-1 Overview ......................................................................................................... 1-1 1-2 Serverboard Features .............................................................
A+ Server 1022G-URF User's Guide vi 2-5 Installing the System into a Rack ................................................................... 2-4 Identifying the Sections of the Rack Rails ...................................................... 2-4 Installing the Outer Rails .
vii Preface Chapter 5 Advanced Serverboard Setup 5-1 Handling the Serverboard ............................................................................... 5-1 Precautions .............................................................................
A+ Server 1022G-URF User's Guide viii 6-3 System Fans ................................................................................................... 6-2 System Fan Failure .....................................................................
Chapter 1 Introduction 1-1 Overview The A+ Server 1022G-URF is a high-end server comprised of two main subsys - tems: the SC815TQ-R700UB 1U server chassis and the H8DGU-F dual processor serverboard. Please refer to our web site for information on operating systems that have been certied for use with the system (www .
1-2 A + SE R VER 1022G-URF User's Manual • Product safety information: http://super-dev/about/policies/safety_information.cfm For support, email support@supermicro.com. 1-2 Serverboard Features At the heart of the A+ SERVER 1022G-URF lies the H8DGU-F , a dual processor serverboard based on the AMD SR5670/SP5100 chipset.
1-3 Chapter 1: Introduction Note: Y ou m ust have R A ID set u p to ena ble t he h ot- swap c a pabi lit y of t he S A T A dr ives. D oc um ent ati on o n R A ID s etup g uid eli nes c a n be fo und o n our we b site.
1-4 A + SE R VER 1022G-URF User's Manual PCI Expansion Slots A riser card (RSC-R1UU-UE16, optional) on the right side of the chassis can sup - port an AOC-PG-i2+ add-on card to provide two additional Gb LAN ports. The left side supports a UIO card and one PCI-E x16 card.
1-5 Chapter 1: Introduction Figure 1-1. AMD SR5670/SP5100 Chipset: System Block Diagram Note: This is a general block diagram. Please see Chapter 5 for details. AMD Socket G34 CPU2 DIMM A0 DIMM A1 DIMM A1 DIMM A0 HT3 Link (8+8)x(8+8)-3.2GT/s HT3 Link 16x16-5.
1-6 A + SE R VER 1022G-URF User's Manual 1-4 Contacting Supermicro Headquarters Address: Super Micro Computer , Inc. 980 Rock Ave. San Jose, CA 95131 U.S.A. T el: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Email: marketing@supermicro.com (General Information) support@supermicro.
Chapter 2: Server Installation 2-1 Chapter 2 Server Installation 2-1 Overview This chapter provides a quick setup checklist to get your A+ SERVER 1022G-URF up and running. Following these steps in the order given should enable you to have the system operational within a minimum amount of time.
2-2 A+ S ERVER 1022G-URF User's Manual installation only in a Restricted Access Location (dedicated equipment rooms, service closets and the like). • This product is not suitable for use with visual display work place devices acccording to §2 of the the German Ordinance for Work with V isual Display Units.
Chapter 2: Server Installation 2-3 Rack Mounting Considerations Ambient Operating T emperature If installed in a closed or multi-unit rack assembly , the ambient operating temperature of the rack environment may be greater than the ambient temperature of the room.
2-4 A+ S ERVER 1022G-URF User's Manual 2-5 Installing the System into a Rack This section provides information on installing the 1022G-URF into a rack unit with the rack rails provided. If the system has already been mounted into a rack, you can skip ahead to Sections 2-6 and 2-7.
Chapter 2: Server Installation 2-5 Installing the Outer Rails Begin by measuring the distance from the front rail to the rear rail of the rack. Attach a short bracket to the front side of the right outer rail and a long bracket to the rear side of the right outer rail.
2-6 A+ S ERVER 1022G-URF User's Manual Figure 2-3. Installing the Server into a Rack Installing the Server into the Rack Y ou should now have rails attached to both the chassis and the rack unit. The next step is to install the server into the rack.
Chapter 2: Server Installation 2-7 Figure 2-4. Installing the Server into a T elco Rack Installing the Server into a T elco Rack T o install the 1022G-URF into a T elco type rack, use two L-shaped brackets on either side of the chassis (four total). First, determine how far follow the server will extend out the front of the rack.
2-8 A+ S ERVER 1022G-URF User's Manual 2-6 Checking the Serverboard Setup After you install the 1022G-URF in the rack, you will need to open the top cover to make sure the serverboard is properly installed and all the connections have been made. Accessing the Inside of the System 1.
Chapter 2: Server Installation 2-9 Figure 2-5. Accessing the Inside of the System 2-7 Checking the Drive Bay Setup Next, you should check to make sure the peripheral drives and the SA T A drives and SA T A backplane have been properly installed and all connections have been made.
2-10 A+ S ERVER 1022G-URF User's Manual Checking the Airow Airow is provided by four sets of 4-cm fans (each set of fans consists of two fans that are mounted back to back). The system component layout was carefully designed to direct sufcient cooling airow to the components that generate the most heat.
Chapter 3: System Interface 3-1 Chapter 3 System Interface 3-1 Overview There are several LEDs on the control panel as well as others on the SAS/SA T A drive carriers to keep you constantly informed of the overall status of the system as well as the activity and health of specic components.
3-2 A + SE R VER 1022G-URF User's Manual Power The main power button is used to apply or remove power from the power supply to the server system. T urning off system power with this button removes the main power but keeps standby power supplied to the system.
Chapter 3: System Interface 3-3 NIC2 Indicates network activity on LAN2 when ashing. 2 1 Note: deactivating the UID LED must be performed in the same way it was activated. (If the UID LED was activated via IPMI, you can only turn the LED off via IPMI and not with the UID button.
3-4 A + SE R VER 1022G-URF User's Manual 3-4 Hard Drive Carrier LEDs Each hard drive carrier has two LEDs. • Green: When illuminated, the green LED on the front of the drive carrier in - dicates drive activity . A connection to the drive backplane enables this LED to blink on and off when that particular drive is being accessed.
4-1 Chapter 4: W arning Statements for AC Systems Chapter 4 Standardized W arning Statements for AC Systems 4-1 About Standardized W arning Statements The following statements are industry standard warnings, provided to warn the user of situations which have the potential for bodily injury .
4-2 A+ Server 1022G-URF User's Manual W arnung WICHTIGE SICHERHEITSHINWEISE Dieses Warnsymbol bedeutet Gefahr. Sie benden sich in einer Situation, die zu V erletzungen führen kann. Machen Sie sich vor der Arbeit mit Geräten mit den Gefahren elektrischer Schaltungen und den üblichen V erfahren zur V orbeugung vor Unfällen vertraut.
4-3 W arning Statements for AC Systems 안전을 위한 주의사항 경고! 이 경고 기호는 위험이 있음을 알려 줍니다. 작업자의 신체에 부상을 야기 할 수 있는 상태에 있게 됩니다.
4-4 A+ Server 1022G-URF User's Manual Installation Instructions W arning! Read the installation instructions before connecting the system to the power source. W arnung V or dem Anschließen des Systems an die Stromquelle die Installationsanweisungen lesen.
4-5 Chapter 4: W arning Statements for AC Systems Circuit Breaker W arning! This product relies on the building's installation for short-circuit (overcurrent) protection.
4-6 A+ Server 1022G-URF User's Manual Power Disconnection W arning 電源切断の警告 システムコン ポ ー ネ ン トの 取り 付 けまた は 取り外しの た め に 、 シャ.
4-7 Chapter 4: W arning Statements for AC Systems ¡Advertencia! El sistema debe ser disconnected de todas las fuentes de energía y del cable eléctrico quitado de los módulos de fuente de alimentación antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema.
4-8 A+ Server 1022G-URF User's Manual Equipment Installation 機器の設置 ト レ ー ニ ン グを受け認 定さ れた人だけが こ の 装 置の 設 置、 交 換、 ま たはサ.
4-9 Chapter 4: W arning Statements for AC Systems ア ク セ ス制限区域 こ のユニ ッ ト は、 ア ク セ ス制限区域 に 設置 さ れ る こ と を想定 し て い ま す 。 .
4-10 A+ Server 1022G-URF User's Manual Battery Handling W arning! There is the danger of explosion if the battery is replaced incorrectly . Replace the battery only with the same or equivalent type recommended by the manufacturer .
4-1 1 Chapter 4: W arning Statements for AC Systems W arnung Bei Einsetzen einer falschen Batterie besteht Explosionsgefahr . Ersetzen Sie die Batterie nur durch den gleichen oder vom Hersteller empfohlenen Batterietyp. Entsorgen Sie die benutzten Batterien nach den Anweisungen des Herstellers.
4-12 A+ Server 1022G-URF User's Manual W arnung Dieses Gerät kann mehr als eine Stromzufuhr haben. Um sicherzustellen, dass der Einheit kein trom zugeführt wird, müssen alle V erbindungen entfernt werden. ¡Advertencia! Puede que esta unidad tenga más de una conexión para fuentes de alimentación.
4-13 Chapter 4: W arning Statements for AC Systems Backplane V oltage バッ ク プレ ーン の 電 圧 シ ス テ ムの稼 働中は危 険な電 圧 ま たは電力 が、 バ ッ ク プ レ .
4-14 A+ Server 1022G-URF User's Manual Comply with Local and National Electrical Codes W arning! Installation of the equipment must comply with local and national electrical codes.
4-15 Chapter 4: W arning Statements for AC Systems Product Disposal W arning! Ultimate disposal of this product should be handled according to all national laws and regulations. יצראה למשחה יקוח םואית !הרהזא תנקתה םייצראהו םיימוקמה למשחה יקוחל תמאות תויהל תביי ח דויצה .
4-16 A+ Server 1022G-URF User's Manual W aarschuwing De uiteindelijke verwijdering van dit product dient te geschieden in overeenstemming met alle nationale wetten en reglementen. ¡Advertencia! Al deshacerse por completo de este producto debe seguir todas las leyes y reglamentos nacionales.
4-17 Chapter 4: W arning Statements for AC Systems W arnung Die Lüfter drehen sich u. U. noch, wenn die Lüfterbaugruppe aus dem Chassis genommen wird. Halten Sie Finger , Schraubendreher und andere Gegenstände von den Öffnungen des Lüftergehäuses entfernt.
4-18 A+ Server 1022G-URF User's Manual W arning! When installing the product, use the provided or designated connection cables, power cables and AC adaptors.
4-19 Chapter 4: W arning Statements for AC Systems Attention Lors de l'installation du produit, utilisez les bables de connection fournis ou désigné. L'utilisation d'autres cables et adaptateurs peut provoquer un dysfonctionnement ou un incendie.
4-20 A+ Server 1022G-URF User's Manual Notes.
Chapter 5: Advanced Serverboard Setup 5-1 Chapter 5 Advanced Serverboard Setup Thi s ch apter c over s t he ste ps re quir ed to i nst all p ro ce ss or s and h eat sin ks to th e H8DGU-F ser ver bo ard, c o nne ct t he dat a an d powe r ca ble s and i nst all a dd - o n ca rds .
5-2 A + SE R V ER 1022G-UTF User's Manual 5-2 Processor and Heatsink Installation Installing the Processors 1. Begin by removing the cover plate that protects the CPU. Lift the lever on the CPU socket until it points straight up. 2. With the lever raised, lift open the silver CPU retention plate.
Chapter 5: Advanced Serverboard Setup 5-3 T riangle 3. Use your thumb and your index nger to hold the CPU. Locate and align pin 1 of the CPU socket with pin 1 of the CPU. Both are marked with a triangle. 4. Align pin 1 of the CPU with pin 1 of the socket.
5-4 A + SE R V ER 1022G-UTF User's Manual Installing a Passive CPU Heatsink 1. Do not apply any thermal grease to the heatsink or the CPU die -- the re - quired amount has already been applied. 2. Place the heatsink directly on top of the CPU so that the heat sink screws are aligned with the mounting holes on the back plate.
Chapter 5: Advanced Serverboard Setup 5-5 5-3 Connecting Cables Now that the processors are installed, the next step is to connect the cables to the serverboard. These include the data (ribbon) cables for the peripherals and control panel and the power cables.
5-6 A + SE R V ER 1022G-UTF User's Manual Figure 5-1. Front Control Panel Header Pins (JF1) See the Connector Denitions section in this chapter for details and pin descrip - tions of JF1. 5-4 I/O Ports The I/O ports are color coded in conformance with the PC 99 specication.
Chapter 5: Advanced Serverboard Setup 5-7 5-5 Installing Memory Figure 5-3. Installing DIMM into Slot CAUTION! Exercise extreme care when installing or removing DIMM modules to prevent any possible damage.
5-8 A + SE R V ER 1022G-UTF User's Manual Memory Population for Optimal Performance -For a Motherboard with One CPU (CPU1) Installed # DIMMS CPU Branch 0 Branch 1 Branch 2 Branch 3 2 DIMMs CPU1 P.
Chapter 5: Advanced Serverboard Setup 5-9 Possible System Memory Allocation & Availability System Device Size Physical Memory A vailable (4 GB T otal System Memory) Firmware Hub ash memory (System BIOS) 1 MB 3.99 GB Local APIC 4 KB 3.99 GB Area Reserved for the chipset 2 MB 3.
5-10 A + SE R V ER 1022G-UTF User's Manual 5-6 Adding PCI Cards PCI Expansion Slots A riser card is used to support an add-on card to the system and comes pre- installed. Installing a PCI Expansion Card 1. Remove the chassis cover . 2. Install the riser card by sliding card into the appropriate slot in the mother - board.
Chapter 5: Advanced Serverboard Setup 5-1 1 Figure 5-4. SUPER H8DGU-F Layout (not drawn to scale) 5-7 Serverboard Details JD1 JPW1 JF1 JI2C1 JI2C2 JOH1 JL1 JWF1 JPL1 JWD JPG1 F AN3 F AN8 F AN2 F AN1 F.
5-12 A + SE R V ER 1022G-UTF User's Manual H8DGU(-F) Quick Reference Jumper Description Default Setting JBT1 CMOS Clear (See Section 5-9) JI2C1/JI2C2 I2C to PCI-E Slot Enable/Disable Both Closed .
Chapter 5: Advanced Serverboard Setup 5-13 5-8 Connector Denitions Power Connectors A 24-pin main power supply connector(JPW1) and three 8-pin CPU PWR connectors (JPW2/JPW3/JPW4) on the motherboard. These power connectors meet the SSI EPS 12V specication.
5-14 A + SE R V ER 1022G-UTF User's Manual Overheat/Fan Fail LED (OH) Connect an LED to the OH connection on pins 7 and 8 of JF1 to provide advanced warning of chassis overheating or fan failure. Refer to the table on the right for pin deni - tions and status indicators.
Chapter 5: Advanced Serverboard Setup 5-15 Universal Serial Bus Ports T wo Universal Serial Bus ports (USB 2.0) are located beside the Keyboard and Mouse PS2 ports. One additional T ype A port (USB6) is included on the motherboard. See the table on the right for pin denitions.
5-16 A + SE R V ER 1022G-UTF User's Manual T -SGPIO The T -SGPIO1/ T -SGPIO2 (Serial General Purpose Input/Output) headers provide a bus between the SA T A c ontroller and the backpane to provide SA T A enclosure man - agement functions.
Chapter 5: Advanced Serverboard Setup 5-17 A TX PS/2 Keyboard and PS/2 Mouse Ports The A TX PS/2 keyboard and PS/2 mouse are located next to the Back Panel USB Ports 0~3 on the motherboard.
5-18 A + SE R V ER 1022G-UTF User's Manual UID Button Pin Denitions Pin# Denition 1 Ground 2 Ground 3 Button In 4 Ground Unit Identier Button In addition to the UID (Unit Identier) button on the rear I/O panel, there is another UID button located on the control panel.
Chapter 5: Advanced Serverboard Setup 5-19 5-9 Jumper Settings Explanation of Jumpers T o modify the operation of the motherboard, jumpers can be used to choose between optional settings. Jumpers create shorts be - tween two pins to change the function of the connector .
5-20 A + SE R V ER 1022G-UTF User's Manual VGA Enable/Disable JPG1 allows you to enable or disable the VGA port. The default position is on pins 1 and 2 to enable VGA.
Chapter 5: Advanced Serverboard Setup 5-21 5-10 Onboard Indicators LAN1/LAN2 LEDs The Ethernet ports (located beside the VGA port) have two LEDs. On each Gb LAN port, one LED blinks to indicate activity while the other may be green, amber or off to indicate the speed of the connection.
5-22 A + SE R V ER 1022G-UTF User's Manual 5-1 1 SA T A Drive Connecti ons SA T A Ports There are no jumpers to congure the SA T A ports, which are designated SA T A0 through SA T A5 .
Chapter 5: Advanced Serverboard Setup 5-23 5-12 Enabling SA T A RAID Now that the hardware is set up, you must install the operating system and the SA T A RAID drivers, if you wish to use RAID with your SA T A drives.
5-24 A + SE R V ER 1022G-UTF User's Manual Figure 5-5. BIOS Setup Screen Enabling SA T A RAI D in the BIOS Before installing the Windows operating system, you must change some settings in the BIOS. Boot up the system and hit the <Delete> key to enter the BIOS Setup Utlility .
Chapter 5: Advanced Serverboard Setup 5-25 Figure 5-7. Adaptec RAID Utility Program Screen Using the DotHill and Adaptec RAID Utility The RAID Utility program allows you to dene the drives you want to include in the RAID array and the mode and type of RAID.
5-26 A + SE R V ER 1022G-UTF User's Manual Installing the RAID Driver During OS Installation Y ou may also use the procedure below to install the RAID driver during the Win - dows OS installation: 1. With the Windows OS installation CD-ROM in the CD drive, restart the sys - tem.
Chapter 5: Advanced Serverboard Setup 5-27 Note: Click the icons showing a hand writing on paper to view the readme les for each item. Click the computer icons to the right of these items to install each item (from top to the bottom) one at a time.
5-28 A + SE R V ER 1022G-UTF User's Manual Note: The SuperDoctor III program and User ’s Manual can be downloaded from the Supermicro web site at http://www .supermicro.com/products/accessories/software/ SuperDoctorIII.cfm .For Linux, we recommend that you use the SuperoDoctor II application instead.
Chapter 5: Advanced Serverboard Setup 5-29 5-14 Serverboard Battery Caution : There is a danger of explosion if the onboard battery is installed upside down, which will reverse its polarites (see Figure 5-1 1). This battery must be re - placed only with the same or an equivalent type recommended by the manufacturer (CR2032).
5-30 A + SE R V ER 1022G-UTF User's Manual Notes.
Chapter 6: Advanced Chassis Setup 6-1 Chapter 6 Advanced Chassis Setup This chapter covers the steps required to install components and perform maintenance on the 815TS-R700UBP chassis. For component installation, follow the steps in the order given to eliminate the most common problems encountered.
6-2 A + SE R VER 1022G-URF User's Manual Figure 6-1. Chassis: Front and Rear Views 6-2 Control Panel The control panel (located on the front of the chassis) must be connected to the JF1 connector on the serverboard to provide you with system status indications.
Chapter 6: Advanced Chassis Setup 6-3 System Fan Failure Fan speed is controlled by system temperature via a BIOS setting. If a fan fails, the remaining fan will ramp up to full speed and the overheat/fan fail LED on the control panel will turn on.
6-4 A + SE R VER 1022G-URF User's Manual Accessing the Drive Bays Hard Drives: Because of their hotswap capability , you do not need to access the inside of the chassis or power down the system to install or replace SA T A drives. Proceed to the next section for instructions.
Chapter 6: Advanced Chassis Setup 6-5 Use caution when working around the hard drive backplane. Do not touch the backplane with any metal objects and make sure no ribbon cables touch the backplane or obstruct the holes, which aid in proper airow .
6-6 A + SE R VER 1022G-URF User's Manual Installing/Removing a Hard Drive 1. T o remove a carrier, push the release button located beside the drive LEDs. 2. Swing the colored handle fully out and use it to pull the unit straight out (see Figure 6-5).
Chapter 6: Advanced Chassis Setup 6-7 2. Depress the two buttons on the top of the chassis to release the top cover and at the same time, push the cover away from you until it stops. Y ou can then lift the top cover from the chassis to gain full access to the inside of the server .
6-8 A + SE R VER 1022G-URF User's Manual Replacing the Power Supply Y ou do not need to shut down the system to replace a power supply module. The redundant feature will keep the system up and running while you replace the failed hot-swap module.
Chapter 7: BIOS 7-1 Chapter 7 BIOS 7-1 Introduction This chapter describes the AMI BIOS Setup Utility for the A+ SERVER 1022G-URF . The AMI ROM BIOS is stored in a Flash EEPROM and can be easily updated. This chapter describes the basic navigation of the AMI BIOS Setup Utility setup screens.
A+ Server 1022G-URF User's Manual 7-2 System Time/System Dat e Y ou can edit this eld to change the system time and date. Highlight System Time or System Date using the <Arrow> keys. Enter new values through the keyboard. Press the <T ab> key or the <Arrow> keys to move between elds.
Chapter 7: BIOS 7-3 W atch Dog Function Allows system to restart when system is inactive more than 5-minutes. The options are Enabled and Disabled . Power Button Function This sets the function of the power button when you turn off the system. Options include 4-second Overide and Instant Off .
A+ Server 1022G-URF User's Manual 7-4 Power Cap This option can decide the highest P-state in the OS. Options include P-state 0 through P-state 4. ACPI SRA T T able This option Enables or Disables the building of the ACPI SRA T T able. CPU Down Core This option sets down core support for the CPU.
Chapter 7: BIOS 7-5 Bank Swizzle Mode This setting Enables or Disables the bank swizzle mode. ECC Conguration ECC Mode This submenu affects the DRAM scrub rate based on its setting. Options include Disabled, Basic , Good, Super , Max and User .
A+ Server 1022G-URF User's Manual 7-6 Legacy USB Support Select "Enabled" to enable the support for USB Legacy . Disable Legacy support if there are no USB devices installed in the system. "Auto" disabled Legacy support if no USB devices are connected.
Chapter 7: BIOS 7-7 Select "Disabled" to allow the data to be transferred from and to the device one sector at a time. Select "Auto" to allows the data transfer from and to the device occur multiple sectors at a time if the device supports it.
A+ Server 1022G-URF User's Manual 7-8 PCI/PnP Conguration Clear NVRAM Select Y es to clear NVRAM during boot-up. The options are Y es and No . Plug & Play O/S Select Y es to allow the OS to congure Plug & Play devices. (This is not required for system boot if your system has an OS that supports Plug & Play .
Chapter 7: BIOS 7-9 I/O port address and IRQ 4 for the interrupt address. Options include Disabled, 3F8/IRQ4 , 3E8/IRQ4 and 2E8/IRQ3 Serial 2 Address This option species the base I/O port address and Interrupt Request address of serial port 2. Select "Disabled" to prevent the serial port from accessing any system resources.
A+ Server 1022G-URF User's Manual 7-10 T erminal T ype Selects the type of the target terminal. Options are ANSI , VT100 and VT -UTF8. VT -UTF8 Combo Key Support Allows you to Enable or Disable VT -UTF8 combination key support for ANSI/ VT100 terminals.
Chapter 7: BIOS 7-1 1 ACPI APIC Support Determines whether to include the ACPI APIC table pointer in the RSDT pointer list. The available options are Enabled and Disabled. Headless Mode Use this setting to Enable or Disable headless operation mode through ACPI.
A+ Server 1022G-URF User's Manual 7-12 IP Address This submenu sets the IP address source as either Static or DHCP . Selecting Static allows you to manually set the IP Address, Subnet Mask and Gateway Address. In the eld provided here enter the IP address in the decimal form of xxx.
Chapter 7: BIOS 7-13 SR56x0 (RD890S) PCIE Error Log This setting allows you set an error log ofr PCIE errors. Options include Y es or No . 7-4 Security Menu AMI BIOS provides a Supervisor and a User password. If you use both passwords, the Supervisor password must be set rst.
A+ Server 1022G-URF User's Manual 7-14 This feature allows you to specify the boot sequence from the list of available CD/ DVD drives. A device that is in parenthesis has been disabled in the corresponding type menu. Retry Boot Devices This option allows you to retry boot devices.
A-1 Appendix A: BIOS Error Beep Codes Appendix A BIOS Error Beep Codes During the POST (Power-On Self-T est) routines, which are performed each time the system is powered on, errors may occur . Non-fatal errors are those which, in most cases, allow the system to continue the boot-up process.
A-2 A + SE R V ER 1022G-URF User's Manual Notes.
Appendix B: Installing Windows B-1 Appendix B Installing Windows After all hardware components have been installed, you must rst congure Intel South Bridge RAID Settings before you install the Windows OS and other software drivers. T o congure RAID settings, please refer to RAID Conguration User Guides posted on our web site at www .
B-2 A + SE R V ER 1022G-URF User's Manual 9. From the Windows XP/Windows 2003 Setup screen, press the <Enter> key . The XP/2003 Setup will automatically load all device les and then, continue the Windows XP/Windows 2003 installation. 10.
Appendix C: System Specications C-1 Appendix C System Specications Processors Dual AMD Opteron 6000 series (AMD Socket G34 type) processors Note: Y ou must install at least two processors for full functions to be supported. Note: Please refer to our web site for a complete listing of supported processors.
C-2 A + SE R V ER 1022G-URF User's Manual Ex pansion Slots One UIO card and one PCI Express x16 slot Serverboard H8DGU-F (Proprietary form factor) Dimensions: 12.28" x 13.05" (312 x 331 mm) Chassis SC815TQ-R700UBP Form Factor: 1U rackmount Dimensions: (WxHxD) 17 x 1.
Appendix C: System Specications C-3 Regulatory Compliance Electromagnetic Emissions: FCC Class A, EN 55022 Class A, EN 61000-3-2/- 3-3, CISPR 22 Class A Electromagnetic Immunity: EN 55024/CISPR 24,.
C-4 A + SE R V ER 1022G-URF User's Manual (continued from front) The products sold by Supermicro are not intended for and will not be used in life support systems, medical equipment, nuclear faci.
デバイスSUPER MICRO Computer 1022G-URFの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
SUPER MICRO Computer 1022G-URFをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはSUPER MICRO Computer 1022G-URFの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。SUPER MICRO Computer 1022G-URFの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。SUPER MICRO Computer 1022G-URFで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
SUPER MICRO Computer 1022G-URFを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はSUPER MICRO Computer 1022G-URFの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、SUPER MICRO Computer 1022G-URFに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちSUPER MICRO Computer 1022G-URFデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。