S UPER S uper S erver 5016I-T S uper S erver 5016I-TF ® USER’S MANUAL Revision 1.0.
Manual Revision 1.0 Release Date: October 6, 2009 The information in this User ’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inac.
Preface About This Manual This manual is written for professional system integrators and PC technicians. It pro- vides information for the installation and use of the SuperServer 5016I-T/5016I-TF . Installation and maintenance shall be performed by experienced technicians only .
iv to this chapter when adding or removing processors or main memory and when recon fi guring the motherboard. Chapter 6: Advanced Chassis Setup Refer to Chapter 6 for detailed information on the SC81 1T -280 chassis.
v Preface Notes.
vi T able of Contents Chapter 1 Introduction 1-1 Overview ......................................................................................................... 1-1 1-2 Motherboard Features ..........................................................
vii T able of Contents Overheat/Fan Fail ........................................................................................... 3-2 NIC2 .............................................................................................................
viii Power On LED ......................................................................................... 5-16 Chassis Intrusion ...................................................................................... 5-17 A TX PS/2 Keyboard and PS/2 Mouse Ports .
Serial A T A Drive Installation ............................................................................ 6-4 SA T A Power Cables ................................................................................... 6-6 DVD-ROM Drive Installation ...
Notes S UPER S ERVER 5016I-T/5016I-TF User's Manual.
Chapter 1 Introduction 1-1 Overview The SuperServer 5016I-T/5016I-TF is a high-end server comprised of two main sub- systems: the SC81 1T -280 1U chassis and the X8SIL/X8SIL-F motherboard. Please refer to our web site for information on operating systems that have been certi fi ed for use with the SuperServer 5016I-T/5016I-TF (www .
1-2 S UPER S ERVER 5016I-T/5016I-TF User's Manual 1-2 Motherboard Features At the heart of the SuperServer 5016I-T/5016I-TF lies the X8SIL/X8SIL-F , a single processor motherboard based on the Intel® 3400/3420 chipset. Below are the main features of the X8SIL/X8SIL-F .
1-3 Chapter 1: Introduction 1-3 Chassis Features System Power The SC81 1T -280 chassis includes a single 280W power supply . Serial A T A Subsystem The SC81 1T -280 chassis was designed to support two Serial A T A drives, which are hot-swappable units.
1-4 S UPER S ERVER 5016I-T/5016I-TF User's Manual Figure 1-1. Intel 3400/3420 Chipset: System Block Diagram Note: This is a general block diagram.
1-5 Chapter 1: Introduction 1-4 Contacting Supermicro Headquarters Address: Super Micro Computer , Inc. 980 Rock A ve. San Jose, CA 95131 U.S.A. T el: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Email: marketing@supermicro.com (General Information) support@supermicro.
1-6 S UPER S ERVER 5016I-T/5016I-TF User's Manual Notes.
Chapter 2: Server Installation 2-1 Chapter 2 Server Installation 2-1 Overview This chapter provides a quick setup checklist to get your SuperServer 5016I- T/5016I-TF up and running. Following the steps in the order given should enable you to have the system operational within a minimal amount of time.
2-2 S UPER S ERVER 5016I-T/5016I-TF User's Manual Choosing a Setup Location Leave enough clearance in front of the rack to enable you to open the front • door completely (~25 inches). Leave approximately 30 inches of clearance in the back of the rack to allow for • suf fi cient air fl ow and ease in servicing.
Chapter 2: Server Installation 2-3 Use a regulating uninterruptible power supply (UPS) to protect the server from • power surges, voltage spikes and to keep your system operating in case of a power failure. Allow the power supply units and hot plug Serial A T A drives to cool before • touching them.
2-4 S UPER S ERVER 5016I-T/5016I-TF User's Manual Figure 2-1. Identifying the Sections of the Rack Rails A B 2-4 Installing the System into a Rack This section provides information on installing the SuperServer 5016I-T/5016I-TF into a rack unit. If the system has already been mounted into a rack, you can skip ahead to Sections 2-5 and 2-6.
Chapter 2: Server Installation 2-5 Installing the Chassis Rails Position the fixed chassis rail sections you just removed along the side of the chassis making sure the fi ve screw holes line up. Note that these two rails are left/right speci fi c. Screw the rail securely to the side of the chassis (see Figure 2-2).
2-6 S UPER S ERVER 5016I-T/5016I-TF User's Manual Figure 2-3. Installing the Server into a Rack Installing the Server into the Rack Y ou should now have rails attached to both the chassis and the rack unit. The next step is to install the server into the rack.
Chapter 2: Server Installation 2-7 Installing the Server into a T elco Rack If you are installing the server into a T elco type rack, follow the directions given on the previous pages for rack installation. The only dif ference in the installation procedure will be the positioning of the rack brackets to the rack.
2-8 S UPER S ERVER 5016I-T/5016I-TF User's Manual 2-5 Checking the Serverboard Setup After you install the 5016I-T/5016I-TF in the rack, you will need to open the unit to make sure the serverboard is properly installed and all the connections have been made.
Chapter 2: Server Installation 2-9 Figure 2-5. Accessing the Inside of the System.
2-10 S UPER S ERVER 5016I-T/5016I-TF User's Manual 2-6 Checking the Drive Bay Setup Next, you should check to make sure the peripheral drives and the Serial A T A drives have been properly installed and all essential connections have been made. Checking the Drives All drives can be accessed from the front of the server .
Chapter 3: System Interface 3-1 Chapter 3 System Interface 3-1 Overview There are several LEDs on the control panel as well as others on the Serial A T A drive carriers to keep you constantly informed of the overall status of the system as well as the activity and health of speci fi c components.
3-2 S UPER S ERVER 5016I-T/5016I-TF User's Manual Overheat/Fan Fail When this LED fl ashes, it indicates a fan failure. When on continuously it indicates an overheat condition, which may be caused by cables obstructing the air fl ow in the system or the ambient room temperature being too warm.
Chapter 3: System Interface 3-3 Power Indicates power is being supplied to the system's power supply units. This LED should normally be illuminated when the system is operating. 3-4 Serial A T A Drive Carrier LEDs Each Serial A T A drive has both a green and a red LED.
3-4 S UPER S ERVER 5016I-T/5016I-TF User's Manual Notes.
Chapter 4: System Safety 4-1 Chapter 4 System Safety 4-1 Electrical Safety Precautions ! Basic electrical safety precautions shall be followed to protect yourself from harm and the SuperServer 5016I-T.
4-2 S UPER S ERVER 5016I-T/5016I-TF User's Manual 4-2 General Safety Precautions Follow these rules to ensure general safety: Keep the area around the SuperServer 5016I-T/5016I-TF clean and free of • clutter . The SuperServer 5016I-T/5016I-TF weighs approximately 30 lbs.
Chapter 4: System Safety 4-3 4-3 ESD Precautions Electrostatic Discharge (ESD) is generated by two objects with different electrical charges coming into contact with each other . An electrical discharge is created to neutralize this difference, which can damage electronic com ponents and printed circuit boards.
4-4 S UPER S ERVER 5016I-T/5016I-TF User's Manual 4-4 Operating Precautions Care must be taken to assure that the chassis cover is in place when the 5016I- T/5016I-TF is operating to assure proper cooling. Out of warranty damage to the system can occur if this practice is not strictly followed.
Chapter 5: Advanced Motherboard Setup 5-1 Chapter 5 Advanced Motherboard Setup This chapter covers the steps required to install the X8SIL/X8SIL-F motherboard into the chassis, connect the data and power cables and install add-on cards. All jumpers and connections are described and a layout and quick reference chart are included for your reference.
5-2 S UPER S ERVER 5016I-T/5016I-TF User's Manual 5-2 Motherboard Installation This section explains the fi rst step of physically mounting the X8SIL/X8SIL-F into the SC81 1T -280 chassis. Following the steps in the order given will eliminate the most common problems encountered in such an installation.
Chapter 5: Advanced Motherboard Setup 5-3 cables (with their locations noted) should be connected. (See the layout on page 5-9 for connector locations.) SA T A drive data cable (I-SA T A0 ~ I-SA T A3) • Control Panel cable (JF1) • Important! Make sure the the cables do not come into contact with the fans.
5-4 S UPER S ERVER 5016I-T/5016I-TF User's Manual 5-4 I/O Ports The I/O ports are color coded in conformance with the PC 99 speci fi cation. See Figure 5-2 below for the colors and locations of the various I/O ports. Figure 5-2. I/O Ports 1. Keyboard (Purple) 6.
Chapter 5: Advanced Motherboard Setup 5-5 Installing the LGA1 156 Processor Press the load lever to release the load plate, which covers the CPU socket, 1. from its locked position. Ge ntly l if t the l oad l ever to op en t he lo ad pl ate. Remove t he pl ate ca p.
5-6 S UPER S ERVER 5016I-T/5016I-TF User's Manual Align the CPU key that is the semi-circle cutouts against the socket keys. 4. Once aligned, carefully lower the CPU straight down to the socket. (Do not drop the CPU on the socket. Do not move the CPU horizontally or vertically .
Chapter 5: Advanced Motherboard Setup 5-7 Installing a Passive CPU Heatsink Do not apply any thermal grease to the heatsink or the CPU die -- the re- 1. quired amount has already been applied. Place the heatsink on top of the CPU so that the four mounting holes are 2.
5-8 S UPER S ERVER 5016I-T/5016I-TF User's Manual Removing the Heatsink War ni ng: We do n ot rec o mme nd re movi ng th e CPU o r the h eat sink . Ho w- ever , if you do ne ed to r emove t he h eats ink , ple ase f oll ow th e inst r uct io ns be low to p revent dam age t o the C PU or ot her c omp one nts.
Chapter 5: Advanced Motherboard Setup 5-9 5-6 Installing Memory Note : Check the Supermicro web site for recommended memory modules. CAUTION Exercise extreme care when installing or removing DIMM modules to prevent any possible damage. DIMM Installation Insert the desired number of DIMMs into the memory slots, starting with 1.
5-10 S UPER S ERVER 5016I-T/5016I-TF User's Manual T able 2 - DDR3 ECC Registered (RDIMM) Memory Support RDIMM 1Gb (x8 DRAM) 2Gb (x8 DRAM) Single Rank Up to 4GB (4 x 1GB DIMM Modules) Up to 8GB (.
Chapter 5: Advanced Motherboard Setup 5-1 1 Figure 5-5. DIMM Installation Note: D u e t o m e m o r y a l l o c a t i o n t o s y s t e m d e v i c e s , t h e a m o u n t o f m e m o r y t h a t rem a in s avai la bl e fo r o p er at i on a l us e wi l l be r e du c e d w he n 4 G B of R A M i s us e d.
5-12 S UPER S ERVER 5016I-T/5016I-TF User's Manual 5-7 Installing a PCI Expansion Card The SC81 1T -280 chassis can accommodate one full-size PCI-Express expansion card with the use of a riser card. Installing an Expansion Card After powering down the system, remove the PCI slot shield.
Chapter 5: Advanced Motherboard Setup 5-13 Figure 5-6. X8SIL/X8SIL-F Layout 5-8 Motherboard Details 1 MAC CODE JPI2C JF1 JPW1 U26 J8 J6 J5 J14 1 J13 U61 T-SGPIO1 T -SGPIO2 J24 JLAN2 JLAN1 SPKR1 JBT1 1.
5-14 S UPER S ERVER 5016I-T/5016I-TF User's Manual X8SIL/X8SIL-F Jumpers Number Jumper Description Default 38 JPUSB1 BP USB0/1 W ake-up Pins 1-2 (Enabled) 25 JBT1 CMOS Clear (See Section 5-9) 13,.
Chapter 5: Advanced Motherboard Setup 5-15 5-9 Connector De fi nitions A TX Power 24-pin Connector Pin De fi nitions (JPW1) Pin# De fi nition Pin # De fi nition 13 +3.3V 1 +3.3V 14 -12V 2 +3.3V 15 COM 3 COM 16 PS_ON 4 +5V 17 COM 5 COM 18 COM 6 +5V 19 COM 7 COM 20 Res (NC) 8 PWR_OK 21 +5V 9 5VSB 22 +5V 10 +12V 23 +5V 1 1 +12V 24 COM 12 +3.
5-16 S UPER S ERVER 5016I-T/5016I-TF User's Manual HDD LED The HDD LED connection is located on pins 13 and 14 of JF1. This LED is used to display HDD activity .
Chapter 5: Advanced Motherboard Setup 5-17 Fan Headers The X8SIL/X8SIL-F has five fan headers, all of which are 4 - pi n fan s. Ho wever , p in s 1-3 o f th e fa n he ade r s are b ackward compatible with the tr adi ti ona l 3 - pi n fan s. Se e th e ta ble on t he r ig ht for p in de fi nitions.
5-18 S UPER S ERVER 5016I-T/5016I-TF User's Manual LAN1/LAN2 (Ethernet Ports) T wo Ethernet ports are located on the I/O backplane. These ports accept RJ45 type cables. NC = No Connection Serial Ports T wo serial ports are included on the X8SIL/X8SIL-F .
Chapter 5: Advanced Motherboard Setup 5-19 NC = No Connection Power Supply I 2 C Connector The Power Supply (I 2 C) connector is located at SMB_PS1 and is used to monitor the status of the power supply , fan and system temperature. See the table on the right for pin de fi nitions.
5-20 S UPER S ERVER 5016I-T/5016I-TF User's Manual 5-10 Jumper Settings Explanation of Jumpers T o modify the operation of the mother- board, jumpers can be used to choose between optional settings. Jumpers create shorts between two pins to change the function of the connector .
Chapter 5: Advanced Motherboard Setup 5-21 LAN1/LAN2 Enable/Disable Change the setting of jumper JPL1 or JPL2 to enable or disable the LAN1 and LAN2 Ethernet ports, respectively . See the table on the right for jumper set- tings. The default setting is enabled.
5-22 S UPER S ERVER 5016I-T/5016I-TF User's Manual 5-1 1 Onboard Indicators LAN1/2 LEDs The Ethernet ports (located on the I/O backplane) have two LEDs. On each port, one LED indicates activity while the other LED may be green, amber or off to indicate the speed of the con- nection.
Chapter 5: Advanced Motherboard Setup 5-23 5-12 SA T A and Floppy Drive Connections SA T A Port Pin De fi nitions (I-SA T A0 ~ I-SA T A5 ) Pin # De fi nition 1 Ground 2 TXP 3 TXN 4 Ground 5 RXN 6 RXP 7 Ground SA T A Ports Six Serial A T A (SA T A) ports (I-SA T A 0~5) are located on the X8SIL-F motherboard (4 SA T A ports on the X8SIL).
5-24 S UPER S ERVER 5016I-T/5016I-TF User's Manual Notes.
Chapter 6: Advanced Chassis Setup 6-1 Chapter 6 Advanced Chassis Setup This chapter covers the steps required to install components and perform mainte- nance on the SC81 1T -280 chassis. For component installation, follow the steps in the order given to eliminate the most common problems encountered.
6-2 S UPER S ERVER 5016I-T/5016I-TF User's Manual Figure 6-2. Chassis Rear View 6-2 Control Panel The control panel (located on the front of the chassis) must be connected to the JF1 connector on the serverboard to provide you with system control buttons and status indicators.
Chapter 6: Advanced Chassis Setup 6-3 6-3 System Fans T wo 10-cm blower fans provide the cooling for the SuperServer 5016I-T/5016I-TF . The chassis includes air seals under the blower fans and at the chassis cross sec- tion, which separates the drive bay area from the serverboard area of the chassis to promote better air fl ow .
6-4 S UPER S ERVER 5016I-T/5016I-TF User's Manual 6-4 Drive Bay Installation/Removal Accessing the Drive Bays Serial A T A Drives: Because of their hot-swap capability , you do not need to access the inside of the chassis or power down the system to install or replace Serial A T A drives.
Chapter 6: Advanced Chassis Setup 6-5 Use caution when working around the SA T A backplane. Do not touch the backplane with any metal objects and make sure no ribbon cables touch the backplane or obstruct the holes, which aid in proper air fl ow . ! Figure 6-4.
6-6 S UPER S ERVER 5016I-T/5016I-TF User's Manual SA T A Power Cables SA T A power cables should be routed so that they do not block the air fl ow through the chassis. See the serverboard layout diagram for the location of the cable con- nections.
Chapter 6: Advanced Chassis Setup 6-7 6-5 Power Supply The 5016I-T/5016I-TF has a single 280 watt power supply , which can operate at 100 or 240 input volts. Use the main power button on the front of the chassis to power off the system and then unplug the AC power cord before removing the power supply .
6-8 S UPER S ERVER 5016I-T/5016I-TF User's Manual Notes.
Chapter 7: BIOS 7-1 Chapter 7 BIOS 7-1 Introduction This chapter describes the AMI BIOS Setup Utility for the X8SIL/X8SIL-F . The AMI ROM BIOS is stored in a Flash EEPROM and can be easily updated. This chapter describes the basic navigation of the AMI BIOS Setup Utility setup screens.
7-2 S UPER S ERVER 5016I-T/5016I-TF User's Manual How to Start the Setup Utility Normally , the only visible Power-On Self-T est (POST) routine is the memory test. As the memory is being tested, press the <Delete> key to enter the main menu of the AMI BIOS Setup Utility .
Chapter 7: BIOS 7-3 When you fi rst enter the AMI BIOS Setup Utility , you will enter the Main setup screen. Y ou can always return to the Main setup screen by selecting the Main tab on the top of the screen. The Main BIOS Setup screen is shown below .
7-4 S UPER S ERVER 5016I-T/5016I-TF User's Manual 7-3 Advanced Setup Con fi gurations Use the arrow keys to select Boot Setup and hit <Enter> to access the submenu items: X BOOT Feature Quick Boot If Enabled, this option will skip certain tests during POST to reduce the time needed for system boot.
Chapter 7: BIOS 7-5 W ait For 'F1' If Error Th is fo r c es t he sy ste m to wai t unt il t he ' F 1' key is pre ss ed i f an e r r or o c c ur s. T he opt io ns ar e Dis able d and Enab led . Hit 'Del' Message Display Th is feat ure d isp lays " Pre ss D EL to r un S etup" d ur ing P OST .
7-6 S UPER S ERVER 5016I-T/5016I-TF User's Manual the components whenever needed. Select Disabled to enhance system stability . The options are Disabled and Enabled.
Chapter 7: BIOS 7-7 Intel® T urbo Boost T echnology (A vailable if Intel® EIST technology is Enabled) This feature allows processor cores to run faster than marked frequency in speci fi c conditions. The options are Disabled and Enabled. C1E Support Select Enabled to use the "Enhanced Halt State" feature.
7-8 S UPER S ERVER 5016I-T/5016I-TF User's Manual Active State Power Management Select Enabled to start Active-State Power Management for signal transactions between L0 and L1 Links on the PCI Express Bus. This maximizes power-saving and transaction speed.
Chapter 7: BIOS 7-9 SA T A#2 Con fi guration (Available if IDE is enabled under "Con fi gure SA T A#1 as" above) Selecting Enhanced will set SA T A#2 to native SA T A mode.
7-10 S UPER S ERVER 5016I-T/5016I-TF User's Manual Select Auto to allow the AMI BIOS to automatically detect the PIO mode. Use this value if the IDE disk drive support cannot be determined. Select 0 to allow the AMI BIOS to use PIO mode 0. It has a data transfer rate of 3.
Chapter 7: BIOS 7-1 1 Select UDMA4 to allow the BIOS to use Ultra DMA mode 4 . It has a data transfer rate of 100 MBs. The options are Auto , SWDMAn, MWDMAn, and UDMAn. S.M.A.R.T . For Hard disk drives Self-Monitoring Analysis and Reporting T echnology (SMART) can help predict impending drive failures.
7-12 S UPER S ERVER 5016I-T/5016I-TF User's Manual PCI Slots 5, 6, 7 & PCI Slot 4 OPROM Use this feature to enable or disable PCI slot Option ROMs. The options are Dis- abled and Enabled. Onboard LAN Option ROM Select This feature selects whether to load the iSCSI or PXE onboard LAN option ROM.
Chapter 7: BIOS 7-13 X Remote Access Con fi guration Remote Access This allows the user to enable the Remote Access feature. The options are Dis- abled and Enabled. If Remote Access is set to Enabled, the following items will display: Serial Port Number This feature allows the user decide which serial port to be used for Console Redirection.
7-14 S UPER S ERVER 5016I-T/5016I-TF User's Manual X Hardware Health Con fi guration This feature allows the user to monitor Hardware Health of the system and review the status of each item when displayed.
Chapter 7: BIOS 7-15 User intervention: No action is required. However , consider checking the CPU fans and the chassis ventilation for blockage. High – The processor is running hot.
7-16 S UPER S ERVER 5016I-T/5016I-TF User's Manual CPU on-die temperature increases, the fan speed will also increase, and vice versa. Select Workstation if your system is used as a W orkstation. Select Server if your system is used as a Server .
Chapter 7: BIOS 7-17 ACPI V ersion Features The options are ACPI v1.0, ACPI v2.0 and ACPI v3.0. Please refer to ACPI's website for further explanation: http://www .
7-18 S UPER S ERVER 5016I-T/5016I-TF User's Manual IP Address - Enter the IP address for this machine. This should be in decimal and in dotted quad form (i.e., 192.168.10.253). The value of each three-digit number separated by dots should not exceed 255.
Chapter 7: BIOS 7-19 on the system. The options are Enabled and Disabled. When enabled the following information are displayed along with their status.
7-20 S UPER S ERVER 5016I-T/5016I-TF User's Manual 7-4 Security Settings The AMI BIOS provides a Supervisor and a User password. If you use both pass- words, the Supervisor password must be set fi rst. Supervisor Password This item indicates if a supervisor password has been entered for the system.
Chapter 7: BIOS 7-21 Use t his fe ature t o co n fi gure Boot Se t tings: X Boot Device Priority This feature allows the user to specify the sequence of priority for the Boot Device. The settings are 1st boot device, 2nd boot device, 3rd boot device, 4th boot device, 5th boot device and Disabled.
7-22 S UPER S ERVER 5016I-T/5016I-TF User's Manual Select the Exit tab from the AMI BIOS Setup Utility screen to enter the Exit BIOS Setup screen.
Chapter 7: BIOS 7-23 Discard Changes and Exit Select this option to quit the BIOS Setup without making any permanent changes to the system con fi guration, and reboot the computer . Select Discard Changes and Exit from the Exit menu and press <Enter>.
7-24 S UPER S ERVER 5016I-T/5016I-TF User's Manual Notes.
Appendix A: POST Error Beep Codes A-1 Appendix A POST Error Beep Codes This section lists POST (Power On Self T est) error beep codes for the AMI BIOS. POST error beep codes are divided into two categories: recoverable and terminal. This section lists Beep Codes for recoverable POST errors.
A-2 S UPER S ERVER 5016I-T/5016I-TF User's Manual Notes.
Appendix B: Installing Windows B-1 Appendix B Installing Windows After all hardware components have been installed, you must fi rst con fi gure Intel South Bridge RAID Settings before you install the Windows OS and other software drivers.
B-2 S UPER S ERVER 5016I-T/5016I-TF User's Manual B-2 Installing Windows to a Non-RAID System Insert Microsoft's Windows OS Setup CD in the CD-ROM drive and the sys- 1. tem will start booting up from the CD. Continue with the installation. The Windows OS Setup screen will display .
C-1 Appendix C: System Speci fi cations Appendix C System Speci fi cations Processors One Intel® 3400 series processor in an LGA1 156 socket Note: Please refer to our web site for a complete listing of supported processors.
C-2 S UPER S ERVER 5016I-T/5016I-TF User's Manual Weight Gross Weight: 30 lbs. (13.6 kg.) System Cooling T wo 10-cm blower fans (F AN-0038L4) System Input Requirements AC Input V oltage: 100-240 V AC Rated Input Current: 5A max.
C-3 Appendix C: System Speci fi cations Notes.
C-4 S UPER S ERVER 5016I-T/5016I-TF User's Manual (continued from front) The products sold by Supermicro are not intended for and will not be used in life support systems, medical equipment, nucl.
デバイスSUPER MICRO Computer SuperServer 5016I-TFの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
SUPER MICRO Computer SuperServer 5016I-TFをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはSUPER MICRO Computer SuperServer 5016I-TFの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。SUPER MICRO Computer SuperServer 5016I-TFの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。SUPER MICRO Computer SuperServer 5016I-TFで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
SUPER MICRO Computer SuperServer 5016I-TFを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はSUPER MICRO Computer SuperServer 5016I-TFの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、SUPER MICRO Computer SuperServer 5016I-TFに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちSUPER MICRO Computer SuperServer 5016I-TFデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。