Supermicroメーカー5038D-Iの使用説明書/サービス説明書
ページ先へ移動 of 114
S UPER S ER VER 5038D-i S UPER ® USER’S MANUAL 1.0a.
The information in this User ’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccuracies that may be contained in this document, makes no commitment to update or to keep current the information in this manual, or to notify any person or organization of the updates.
iii Preface Preface About This Manual This manual is written for professional system integrators and PC technicians. It provides information for the installation and use of the SuperServer 5038D-i. In- stallation and maintenance should be performed by experienced technicians only .
S UPER S ERVER 5038D-i User's Manual iv Chapter 5: Advanced Serverboard Setup Chapter 5 provides detailed information on the X10SLL-F serverboard, including the locations and functions of connections, headers and jumpers. Refer to this chapter when adding or removing processors or main memory and when recon fi guring the serverboard.
v Preface Notes.
vi T able of Contents Chapter 1 Introduction 1-1 Overview ......................................................................................................... 1-1 1-2 Motherboard Features ..........................................................
vii T able of Contents Redundant Power Supplies .......................................................................... 4-12 Backplane V oltage ........................................................................................ 4-13 Comply with Local and National Electrical Codes .
viii S UPER S ERVER 5038D-i User's Manual Fan Failure ...................................................................................................... 6-6 Replacing the System Fan ............................................................
Chapter 1 Introduction 1-1 Overview The SuperServer 5038D-i is a high-end server comprised of two main subsystems: the SC731i-300B server chassis and the X10SLL-F single processor motherboard. Please refer to our web site for information on operating systems that have been certi fi ed for use with the system (www .
1-2 S UPER S ERVER 5038D-i User's Manual 1-2 Motherboard Features At the heart of the SuperServer 5038D-i lies the X10SLL-F , a single processor motherboard based on the Intel® C222 chipset. Below are the main features of the X10SLL-F (see Figure 1-1 for a block diagram of the chipset).
1-3 Chapter 1: Introduction 1-3 Chassis Features The SC731i-300B is a mini-tower chassis with a unique design that allows most con fi gurations to be performed without the need for tools The following is a general outline of the main features of the SC731i-300B chassis.
1-4 S UPER S ERVER 5038D-i User's Manual Figure 1-1. Intel C222 Chipset: System Block Diagram Note: This is a general block diagram. Please see Chapter 5 for details.
1-5 Chapter 1: Introduction 1-4 Contacting Supermicro Headquarters Address: Super Micro Computer , Inc. 980 Rock Ave. San Jose, CA 95131 U.S.A. T el: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Email: marketing@supermicro.com (General Information) support@supermicro.
1-6 S UPER S ERVER 5038D-i User's Manual Notes.
Chapter 2: System Setup 2-1 Chapter 2 System Setup 2-1 Overview This chapter provides a quick setup checklist to get your SuperServer 5038D-i up and running. Following the steps in the order given should enable you to have the system operational within a minimal amount of time.
2-2 S UPER S ERVER 5038D-i User's Manual Figure 2-1. Accessing the Inside of the 5038D-i 1 3 Release T ab Handle.
Chapter 3: System Interface 3-1 Chapter 3 System Interface 3-1 Overview There are four LEDs on the control panel to keep you constantly informed of the overall status of the system as well as the activity and health of speci fi c components. The control panel also is where to fi nd the main power on/off button.
3-2 S UPER S ERVER 5038D-i User's Manual NIC Indicates network activity on the Gigabit LAN port when fl ashing. Overheat/Fan Fail When this LED fl ashes it indicates a fan failure.
4-1 Chapter 4: W arning Statements for AC Systems Chapter 4 Standardized W arning Statements for AC Systems 4-1 About Standardized W arning Statements The following statements are industry standard warnings, provided to warn the user of situations which have the potential for bodily injury .
4-2 S UPER S ERVER 5038D-i User's Manual W arnung WICHTIGE SICHERHEITSHINWEISE Dieses W arnsymbol bedeutet Gefahr . Sie be fi nden sich in einer Situation, die zu V erletzungen führen kann.
4-3 W arning Statements for AC Systems 안전을 위한 주의사항 경고! 이 경고 기호는 위험이 있음을 알려 줍니다. 작업자의 신체에 부상을 야기 할 수 있는 상태에 있게 됩니다.
4-4 S UPER S ERVER 5038D-i User's Manual Installation Instructions W arning! Read the installation instructions before connecting the system to the power source. W arnung V or dem Anschließen des Systems an die Stromquelle die Installationsanweisungen lesen.
4-5 Chapter 4: W arning Statements for AC Systems Circuit Breaker W arning! This product relies on the building's installation for short-circuit (overcurrent) protection.
4-6 S UPER S ERVER 5038D-i User's Manual Power Disconnection W arning 電源切断の警告 システムコン ポ ー ネ ン トの 取り 付 けまた は 取り 外し の た め に 、 .
4-7 Chapter 4: W arning Statements for AC Systems ¡Advertencia! El sistema debe ser disconnected de todas las fuentes de energía y del cable eléctrico quitado de los módulos de fuente de alimentación antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema.
4-8 S UPER S ERVER 5038D-i User's Manual Equipment Installation 機器の設置 ト レー ニ ン グを受 け認定さ れた人だけが こ の 装 置の 設 置、 交換、 ま たはサ.
4-9 Chapter 4: W arning Statements for AC Systems ア ク セ ス 制限区域 この ユ ニ ッ ト は 、 ア ク セ ス制限区域 に 設置 さ れ る こ と を想定 し て い ま す .
4-10 S UPER S ERVER 5038D-i User's Manual Battery Handling W arning! There is the danger of explosion if the battery is replaced incorrectly . Replace the battery only with the same or equivalent type recommended by the manufacturer .
4-1 1 Chapter 4: W arning Statements for AC Systems W arnung Bei Einsetzen einer falschen Batterie besteht Explosionsgefahr . Ersetzen Sie die Batterie nur durch den gleichen oder vom Hersteller empfohlenen Batterietyp. Entsorgen Sie die benutzten Batterien nach den Anweisungen des Herstellers.
4-12 S UPER S ERVER 5038D-i User's Manual W arnung Dieses Gerät kann mehr als eine Stromzufuhr haben. Um sicherzustellen, dass der Einheit kein trom zugeführt wird, müssen alle V erbindungen entfernt werden. ¡Advertencia! Puede que esta unidad tenga más de una conexión para fuentes de alimentación.
4-13 Chapter 4: W arning Statements for AC Systems Backplane V oltage バ ッ ク プ レー ン の電圧 シ ス テ ムの稼働 中は危 険な電圧 ま た は電 力が、 バッ ク プレ .
4-14 S UPER S ERVER 5038D-i User's Manual Comply with Local and National Electrical Codes W arning! Installation of the equipment must comply with local and national electrical codes.
4-15 Chapter 4: W arning Statements for AC Systems Product Disposal W arning! Ultimate disposal of this product should be handled according to all national laws and regulations. יצראה למשחה יקוח םואית ! הרהזא תנקתה םייצראהו םיימוקמה למשחה יקוחל תמאות תויהל תבייח דויצה .
4-16 S UPER S ERVER 5038D-i User's Manual W aarschuwing De uiteindelijke verwijdering van dit product dient te geschieden in overeenstemming met alle nationale wetten en reglementen. ¡Advertencia! Al deshacerse por completo de este producto debe seguir todas las leyes y reglamentos nacionales.
4-17 Chapter 4: W arning Statements for AC Systems W arnung Die Lüfter drehen sich u. U. noch, wenn die Lüfterbaugruppe aus dem Chassis genommen wird. Halten Sie Finger , Schraubendreher und andere Gegenstände von den Öffnungen des Lüftergehäuses entfernt.
4-18 S UPER S ERVER 5038D-i User's Manual W arning! When installing the product, use the provided or designated connection cables, power cables and AC adaptors.
4-19 Chapter 4: W arning Statements for AC Systems Attention Lors de l'installation du produit, utilisez les bables de connection fournis ou désigné. L'utilisation d'autres cables et adaptateurs peut provoquer un dysfonctionnement ou un incendie.
4-20 S UPER S ERVER 5038D-i User's Manual Notes.
Chapter 5: Advanced Motherboard Setup 5-1 Chapter 5 Advanced Motherboard Setup Th is ch apter c ove rs t he ste ps re quir ed to i nst all p ro ce ss or s and h eat sinks t o the X10SLL-F mot her b oar d, c onn ec t the d ata a nd po wer c ab les a nd ins ta ll add - on c ard s.
5-2 S UPER S ERVER 5038D-i User's Manual 5-2 Processor and Heatsink Installation Notes: • Always connect the power cord last and always remove it before adding, re- moving or changing any hardware components. Make sure that you install the processor into the CPU socket before you install the CPU heatsink.
Chapter 5: Advanced Motherboard Setup 5-3 5. Align the CPU key , which is a semi- circle cutout, against the socket key , which is the notch below the gold color dot on the side of the socket. 6. Align pin 1 of the CPU against pin 1 of the CPU socket.
5-4 S UPER S ERVER 5038D-i User's Manual Thermal Grease Heatsink Fins Installing the Heatsink 1. Locate the CPU Fan power connec- tor on the motherboard. 2. Position the heatsink so that the heatsink fan wires are closest to the CPU fan power connector and are not interfered with other compo- nents.
Chapter 5: Advanced Motherboard Setup 5-5 8. Repeat Step 7 to insert all four heatsink fasteners into the mounting holes. 9. Once all four fasteners are securely inserted into the mounting holes, and the heatsink is properly installed on the motherboard, connect the heatsink fan wires to the CPU Fan connector .
5-6 S UPER S ERVER 5038D-i User's Manual 5-3 Connecting Cables Now that the processors are installed, the next step is to connect the cables to the motherboard. These include the data (ribbon) cables for the peripherals and control panel and the power cables.
Chapter 5: Advanced Motherboard Setup 5-7 Figure 5-1. Front Control Panel Header Pins (JF1) 5-4 I/O Ports The I/O ports on the motherboard are located at the rear of the system. See Figure 5-2 below for the locations of the various I/O ports. Figure 5-2.
5-8 S UPER S ERVER 5038D-i User's Manual 5-5 Installing Memory Note: Check the Supermicro web site for recommended memory modules. CAUTI O N E x e r c i s e e xt r e m e ca r e w h e n i n s ta l l i n g o r r e m o v i n g D I MM m o d u l es to pr event any po ss ibl e dam age.
Chapter 5: Advanced Motherboard Setup 5-9 Pop ulat ing t he se DI M M mo dul es wi th a pa ir of m emo r y m odu le s of the s am e ty pe an d s am e si ze wi ll re s ul t i n i nt er le av e d m em ory , wh ich wi ll im pr o v e me mo ry pe r fo r man ce.
5-10 S UPER S ERVER 5038D-i User's Manual Possible System Memory Allocation & A vailability System Device Size Physical Memory Remaining (-A vailable) (4 GB T otal System Memory) Firmware Hub fl ash memory (System BIOS) 1 MB 3.99 Local APIC 4 KB 3.
Chapter 5: Advanced Motherboard Setup 5-1 1 5-6 Adding PCI Cards PCI Expansion Slots Three standard size PCI expansion (add-on) cards may be added to the system.
5-12 S UPER S ERVER 5038D-i User's Manual Figure 5-4. SUPER X10SLL-F Layout 5-7 Motherboard Details FA N 2 JP9 SW1 T -SGPIO1 JSTBY1 JIPMB1 JPW2 JSD1 LED3 LED2 JD1 LED5 LED1 JPI2C1 BT1 JPW1 JTPM1 FA N A FA N 3 FA N 1 FA N 2 FA N 4 JPL1 JPL2 JPME2 JWD1 JPG1 JBR1 JPME1 J19 J18 J7 JVR1 JI2C1 JI2C2 JOH1 JP8 JL1 JP2 JP1 JP7 USB 3.
Chapter 5: Advanced Motherboard Setup 5-13 US B 4/ 5, 6/ 7 ( 2 .0) Bac k pane l US B 2.0 Po r t s 4/ 5, 6 / 7 US B 8/ 9 Front Panel Accessible USB 2.0 Headers 8/9 VGA Backpanel VGA Port Jumper Descrip.
5-14 S UPER S ERVER 5038D-i User's Manual 5-8 Connector De fi nitions Processor Power Pin De fi nitions (JPW2) Pins De fi nition 1/2 Ground 3/4 +12V A TX Power 24-pin Connector Pin De fi nitions (JPW1) Pin# De fi nition Pin # De fi nition 13 +3.
Chapter 5: Advanced Motherboard Setup 5-15 NIC1/NIC2 (LAN1/LAN2) The NIC (Network Interface Controller) LED connection for LAN port 1 is located on pins 1 1 and 12 of JF1, and the LED connection for LAN Port 2 is on pins 9 and 10. Attach NIC LED cables to NIC1 LED and NIC2 LED to display network activities for LAN 1 and LAN2.
5-16 S UPER S ERVER 5038D-i User's Manual Power Button The Power Button connection is located on pins 1 and 2 of JF1. Momentarily contacting both pins will power on/off the system. This button can also be con fi g- ured to function as a suspend button (see BIOS Setup).
Chapter 5: Advanced Motherboard Setup 5-17 Fan Header Pin De fi nitions Pin# De fi nition 1 Ground (Black) 2 +12V (Red) 3 T achometer 4 PWM_Control Fan Headers The X10SLL-F has five fan headers (Fan1 ~ Fan4 and FanA). These are 4-pin fan headers and work with IPMI to moni- tor and change fan speed as required based on the system temperature.
5-18 S UPER S ERVER 5038D-i User's Manual Power Supply I 2 C Connector The Power Supply (I 2 C) connector is located at JPI 2 C on the motherboard. This connector monitors the status of the power supply , fan and system tempera- ture. See the table on the right for pin de fi nitions.
Chapter 5: Advanced Motherboard Setup 5-19 DOM PWR Connector The Disk-On-Module (DOM) power con- nector , located at JSD1, provides 5V (Gen1/Gen) power to a solid state DOM storage device connected to one of the SA T A ports. See the table on the right for pin de fi nitions.
5-20 S UPER S ERVER 5038D-i User's Manual 5-9 Jumper Settings Explanation of Jumpers T o modify the operation of the mother- board, jumpers can be used to choose between optional settings. Jumpers cre- ate shorts between two pins to change the function of the connector .
Chapter 5: Advanced Motherboard Setup 5-21 LAN Port Enable/Disable Use J PL 1 /JP L 2 to en abl e or di sa ble L AN Por ts 1 an d 2 on t he mot he rb oa rd. Se e th e ta ble o n th e ri ght f or ju mpe r set t ing s. Th e defa ult s et tin g is en abl ed.
5-22 S UPER S ERVER 5038D-i User's Manual Management Engine (ME) Recovery Use Jumper JPME1 to select ME Firmware Recovery mode, which will limit resource allocation for essential system operation only in order to maintain normal power operation and management.
Chapter 5: Advanced Motherboard Setup 5-23 5-10 Onboard Indicators LAN1/LAN2 LEDs The Ethernet ports (located beside the VGA port) have two LEDs. On each Giga- bit LAN port, one LED indicates activity when blinking while the other LED may be green, amber or off to indicate the speed of the connection.
5-24 S UPER S ERVER 5038D-i User's Manual 5-1 1 SA T A Drive Connections SA T A Port Pin De fi nitions Pin # De fi nition 1 Ground 2 TXP 3 TXN 4 Ground 5 RXN 6 RXP 7 Ground SA T A Ports T wo SA T A 3.0 and four SA T A 2.0 ports are included on the motherboard.
Chapter 5: Advanced Motherboard Setup 5-25 5-12 Installing Software The Supermicro ftp site contains drivers and utilities for your system at ftp://ftp. supermicro.com . Some of these must be installed, such as the chipset driver . After accessing the ftp site, go into the CDR_Images directory and locate the ISO fi le for your motherboard.
5-26 S UPER S ERVER 5038D-i User's Manual SuperDoctor® 5 The Supermicro SuperDoctor 5 is a program that functions in a command-line or web-based interface in Windows and Linux operating systems.
Chapter 5: Advanced Motherboard Setup 5-27 5-13 Onboard Battery Please handle used batteries carefully . Do not damage the battery in any way; a damaged battery may release hazardous materials into the environment. Do not discard a used battery in the garbage or a public land fi ll.
5-28 S UPER S ERVER 5038D-i User's Manual Notes.
Chapter 6: Advanced Chassis Setup 6-1 Chapter 6 Advanced Chassis Setup This chapter covers the steps required to install components and perform simple maintenance on the SC731i-300B chassis. Following the component installation steps in the order given will eliminate most common problems.
6-2 S UPER S ERVER 5038D-i User's Manual 6-2 Front Control Panel The front control panel must be connected to the JF1 connector on the motherboard to provide you with system status and alarm indications. A ribbon cable has bundled these wires together to simplify this connection.
Chapter 6: Advanced Chassis Setup 6-3 Figure 6-2. Chassis Rear View PCI Expansion Slots I/O Backplane (see Figure 5-2) Power Supply.
6-4 S UPER S ERVER 5038D-i User's Manual 6-3 Front Bezel A bezel may be installed to cover the front of the chassis. Front Bezel Installation 1. Remove the dummy cover (A) on the peripheral drive bay . 2. Push the front bezel into place on the front of the chassis to complete the installation (see Figure 6-4).
Chapter 6: Advanced Chassis Setup 6-5 6-4 Removing the Chassis Cover The left side cover of the chassis must be removed before replacing the system fan or installing and removing hard drives. Removing the Chassis Cover: 1. Power down the server and disconnect it from the power source.
6-6 S UPER S ERVER 5038D-i User's Manual Figure 6-5. Replacing the System Fan 6-5 System Fans The SC731 includes a super quiet system fan that provides cooling for the chassis. No tools or screws are required to install the system fan. Fan Failure Under normal operation, the chassis fan and the power supply fan both run continu- ously .
Chapter 6: Advanced Chassis Setup 6-7 6-6 Drive Bay Installation The SC731 chassis must be powered-down before hard drives can be removed from the hard drive carriers, which are not hot-swappable. SA T A Drives The SA T A drive IDs are precon fi gured as 0 through 3 in order from bottom to top.
6-8 S UPER S ERVER 5038D-i User's Manual Figure 6-6. Rotating the Hard Drive Cage Release T ab (A) HDD Cage (B) Figure 6-7. Removing a Hard Drive Carrier from the Hard Drive Cage 1 3 Release T ab.
Chapter 6: Advanced Chassis Setup 6-9 Installing Drives in the Optional Drive Bays The SC731 chassis has two empty drive bays that support optional devices such as a DVD-ROM. Installing an Optional Device 1. Power down the server and disconnect it from the power source.
6-10 S UPER S ERVER 5038D-i User's Manual 6-7 Power Supply The SC731 chassis includes a 300-watt power supply . The power supply has the ca- pability to automatically sense and operate with an input voltage of 100 or 240V AC. If it becomes necessary to replace the power supply , follow the instructions below .
Chapter 7: BIOS 7-1 Chapter 7 BIOS 7-1 Introduction This chapter describes the AMI BIOS Setup Utility for the X10SLM-F/X10SLL-F/ X10SLL-SF/X10SLL-S . The ROM BIOS is stored in a Flash EEPROM and can be easily updated. This chapter describes the basic navigation of the AMI BIOS Setup Utility setup screens.
7-2 S UPER S ERVER 5038D-i User's Manual How to Start the Setup Utility Normally , the only visible Power-On Self-T est (POST) routine is the memory test. As the memory is being tested, press the <Delete> key to enter the main menu of the AMI BIOS Setup Utility .
Chapter 7: BIOS 7-3 The following Main menu items will be displayed: System Time/System Date Use this option to change the system time and date. Highlight System Time or System Date using the arrow keys. Enter new values through the keyboard. Press the <T ab> key or the arrow keys to move between fi elds.
7-4 S UPER S ERVER 5038D-i User's Manual 7-3 Advanced Setup Con fi gurations Use the arrow keys to select Boot Setup and press <Enter> to access the submenu items: W arning : T ake Caution when changing the Advanced settings.
Chapter 7: BIOS 7-5 Bootup Num-Lock Thi s feat ure s ele ct s th e Power- on st ate fo r the N uml oc k key . Th e opt ion s are O f f and On . W ait For 'F1' If Error This feature fo rc es t he syste m to wai t unti l the ' F 1' ke y i s pre ss ed if a n er ro r oc - cu rs .
7-6 S UPER S ERVER 5038D-i User's Manual CPU Con fi guration The following CPU information will be displayed: • T ype of CPU • CPU Signature • Microcode Patch • Maximum CPU Speed •.
Chapter 7: BIOS 7-7 Hyper-threading Select Enabled to support Intel Hyper-threading T echnology to enhance CPU per- formance. The options are Enabled and Disabled. Active Processor Cores This feature determines how many CPU cores will be activated for each CPU.
7-8 S UPER S ERVER 5038D-i User's Manual CPU AES Select Enable to enable Intel CPU Advanced Encryption Standard (AES) Instruc- tions for CPU to enhance data integrity .
Chapter 7: BIOS 7-9 1-Core Ratio Limit (A vailable when "T urbo Mode" is set to Enabled) This increases (multiplies) 1 clock speed in the CPU core in relation to the bus speed when one CPU core is active. Press "+" or "-" on your keyboard to change this value.
7-10 S UPER S ERVER 5038D-i User's Manual CPU C3 Report (A vailable when "CPU C-States" is set to Enabled) Select Enabled to allow the BIOS to report the CPU C3 State (ACPI C2) to the operating system. During the CPU C3 State, the CPU clock generator is turned off.
Chapter 7: BIOS 7-1 1 LakeTiny Feature Select Enabled for LakeT ing feature support. The options are Disabled and En- abled. ACPI T State Select Enabled for ACPI T state (processor throttling) feature support.
7-12 S UPER S ERVER 5038D-i User's Manual This item allows the generation con fi guration of PEG0 on the PCI-E slot. The options are Auto , Gen1, Gen2 and Gen3. PEG1 - Gen X This item allows the generation con fi guration of PEG1 on the PCI-E slot.
Chapter 7: BIOS 7-13 • CAS Latency (tCL) • Minimum Delay T ime • CAS to RAS (tRCDmin) • Row Precharge (tRPmin) • Active to Precharege (tRASmin) Memory Frequency Limiter This feature sets the limit of memory frequency for DIMM modules installed on the the motherboard.
7-14 S UPER S ERVER 5038D-i User's Manual EHCI2 Select Enabled to enable EHCI (Enhanced Host Controller Interface) Controller 2 for USB 2.0 support. One EHCI controller must always be enabled. The settings are Enabled and Disabled.. Legacy USB Support This feature enables support for legacy USB devices.
Chapter 7: BIOS 7-15 SA T A Con fi guration of the SA T A Devices and displays the following items: SA T A Controllers This item Enables or Disables the built-in SA T A controllers on the motherboard. The options are Enabled and Disabled. SA T A Mode Selection This item selects the mode for the installed SA T A drives.
7-16 S UPER S ERVER 5038D-i User's Manual Serial A T A Port 0~ Port 5 This item displays the information detected on the installed SA T A drives on the particular SA T A port.
Chapter 7: BIOS 7-17 VGA Palette Snoop Se lec t Ena ble d to su ppo r t VG A pal et te re gist er sn oo pin g whi ch w il l all ow th e PCI c a rds t hat do n ot c ont ain t he ir own VG A co lo r pal et te to exam ine t he vi de o c ard s pal et te and m imi c it fo r pr ope r c olo r dis play .
7-18 S UPER S ERVER 5038D-i User's Manual ment) to bo ot th e c omp uter u sin g a PXE devi ce i nst all ed in a L AN p or t spe ci fi ed. Se lec t D isa bl ed to p revent sys tem bo ot us ing a d evic e in sta lle d in a L AN p or t. The options are Disabled, PXE and iSCSI.
Chapter 7: BIOS 7-19 • SPS V ersion • ME FW (Firmware) Status V alue • ME FW State • ME FW Operation State • ME FW Error Code • ME NM FW Status V alue • BIOS Booting Mode • Cores Disab.
7-20 S UPER S ERVER 5038D-i User's Manual SOL Change Settings This feature speci fi es the base I/O port address and the Interrupt Request ad- dress of SOL Serial Port. Select Auto to let the BIOS automatically assign the base I/O and IRQ address.
Chapter 7: BIOS 7-21 Stop Bits A stop bit indicates the end of a serial data packet. Select 1 Stop Bit for standard serial data communication. Select 2 Stop Bits if slower devices are used.
7-22 S UPER S ERVER 5038D-i User's Manual Console Redirection (for EMS) Select Enabled to use a COM Port selected by the user for Console Redirection.
Chapter 7: BIOS 7-23 7-4 Event Logs Change SMBIOS Event Log Settings Enabling/Disabling Options SMBIOS Event Log Change this item to enable or disable all features of the SMBIOS Event Logging during system boot. The options are Enabled and Disabled.
7-24 S UPER S ERVER 5038D-i User's Manual SMBIOS Event Long Standard Settings Log System Boot Event This option toggles the System Boot Event logging to enabled or disabled.
Chapter 7: BIOS 7-25 IPMI The following IPMI information will be displayed: • IPMI Firmware Revision • IPMI Status System Event Log This feature is used to change the Sytem Event Log (SEL) con fi guration. SEL Components - Change this item to enable or disable all features of System Event Logging.
7-26 S UPER S ERVER 5038D-i User's Manual BMC Network Con fi guration LAN Channel 1 : This feature allows the user to con fi gure the settings for LAN1 Port. Update IPMI LAN Con fi guration This feature allows the BIOS to implement any IP/MAC address changes at the next system boot.
Chapter 7: BIOS 7-27 7-5 Boot Settings Use t his fe ature t o co n fi gure Boot Settings: Set Boot Priority This option prioritizes the order of bootable devices that the system to boot from. Press [ENTER] on each entry from top to bottom to select devices.
7-28 S UPER S ERVER 5038D-i User's Manual Delete Boot Option This feature allows the user to delete a previously de fi ned boot device from which the systems boots during startup.
Chapter 7: BIOS 7-29 7-6 Security Settings T h i s m e n u a l l o w s t h e u s e r t o c o n fi gure the following security settings for the syst em. • If the Administrator password is de fi ned ONL Y - this controls access to the BIOS setup ONL Y .
7-30 S UPER S ERVER 5038D-i User's Manual 7-7 Save & Exit Select the Exit tab from the BIOS Setup Utility screen to enter the Exit BIOS Setup screen. Discard Changes and Exit Select this option to quit the BIOS Setup without making any permanent changes to the system con fi guration, and reboot the computer .
Chapter 7: BIOS 7-31 Restore Optimized Defaults T o set this feature, select Restore Defaults from the Exit menu and press <Enter>. These are factory settings designed for maximum system stability , but not for maximum performance.
7-32 S UPER S ERVER 5038D-i User's Manual Notes.
Appendix A: BIOS Error Beep Codes A-1 BIOS Error Beep Codes Beep Code/LED Error Message Description 1 beep Refresh Circuits have been reset. (Ready to power up) 5 short beeps Memory error No memory de.
A-2 S UPER S ERVER 5038D-i User's Manual Notes.
B-1 Appendix B: System Speci fi cations Appendix B System Speci fi cations Processors Single Intel® Xeon® E3-1200 v3 or 4th Gen Core™ i3 processor in an LGA1 150 socket No te: Pl ea se r efe r to o ur we b si te fo r a c om pl ete l is ti ng of s up po r te d pr o ce ss o rs .
B-2 S UPER S ERVER 5038D-i User's Manual Chassis SC731i-300B (Mini-tower) Dimensions: (WxHxD) 7.25 x 14.25 x 16.75 in. (184 x 362 x 425 mm) Weight Gross (Bare Bone): 23.
B-3 Appendix B: System Speci fi cations Disclaimer (continued from front) The products sold by Supermicro are not intended for and will not be used in life support systems, medical equipment, nuclear.
B-4 S UPER S ERVER 5038D-i User's Manual Notes.
デバイスSupermicro 5038D-Iの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Supermicro 5038D-Iをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはSupermicro 5038D-Iの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Supermicro 5038D-Iの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Supermicro 5038D-Iで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Supermicro 5038D-Iを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はSupermicro 5038D-Iの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Supermicro 5038D-Iに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちSupermicro 5038D-Iデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。