SUPERSER VER 6028R-WTR 6028R-WTR T ® S UPER USER’S MANUAL Revision 1.0.
The information in this User ’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccuracies that may be contained in this document, makes no commitment to update or to keep current the information in this manual, or to notify any person or organization of the updates.
iii Preface Preface About This Manual This manual is written for professional system integrators and PC technicians. It provides information for the installation and use of the SuperServer 6028R-WTR(T). Installation and maintainance should be performed by experienced technicians only .
SUPERSERVER 6028R-WTR(T) USER'S MANUAL iv Chapter 5: Advanced Serverboard Setup Chapter 5 provides detailed information on the X10DRW -i(T) serverboard, including the locations and functions of connections, headers and jumpers. Refer to this chapter when adding or removing processors or main memory and when recon fi guring the serverboard.
Notes Preface v.
vi T able of Contents Chapter 1 Introduction 1-1 Overview ......................................................................................................... 1-1 1-2 Serverboard Features ..........................................................
vii Chapter 3 System Interface 3-1 Overview ......................................................................................................... 3-1 3-2 Control Panel Buttons .......................................................................
viii SUPERSERVER 6028R-WTR(T) USER'S MANUAL 5-4 Installing the Processor and Heatsink ............................................................ 5-5 Installing an LGA 201 1 Processor .............................................................
ix T able of Contents Chapter 7 BIOS 7-1 Introduction ...................................................................................................... 7-1 Starting BIOS Setup Utility ..............................................................
SUPERSERVER 6028R-WTR(T) USER'S MANUAL x Notes.
Chapter 1 Introduction 1-1 Overview The SuperServer 6028R-WTR(T) is a high-end server comprised of two main subsystems: the SC815TS-R740WBP 2U chassis and the X10DR W-i(T) dual processor serverboard. Please refer to our web site for information on operating systems that have been certi fi ed for use with the system ( www .
1-2 SUPERSERVER 6028R-WTR(T) USER'S MANUAL 1-2 Serverboard Features The SuperServer 6028R-WTR(T) is built around the X10DRW -i(T), a dual processor serverboard based on the Intel PCH-C612 chipset and designed to provide maximum performance. Below are the main features of the X10DRW -i(T),.
1-3 Chapter 1: Introduction Rear I/O Ports Ports on the I/O backplane includes a VGA port, four USB 2.0 ports, two gigabit (6028R-WTR) or 10-gigabit (6028R-WTRT) Ethernet ports and one IPMI port. A UID (Unit Identi fi er) button and LED are also located beside the VGA port.
1-4 SUPERSERVER 6028R-WTR(T) USER'S MANUAL 1-6 Advanced Power Management Intel® Intelligent Power Node Manager (IPNM) The Intel ® Intelligent Power Node Manager (IPNM) provides your system with real-time thermal control and power management for maximum energy ef fi ciency .
1-5 Chapter 1: Introduction Figure 1-1. Intel PCH-C612 Chipset: System Block Diagram Note: This is a general block diagram. Please see Chapter 5 for details. x16 P1 P1 P0 P0 CPU FRONT CPU DMI PE1 PE2 PE3 PE3 PE1 PE2 DDR4 DIMM 4,5 port 0,1 REAR DDR4 DIMM #1 #2 DDR4 DIMM A G x16 RIGHT SLOT SXB2 PCIE 3.
1-6 SUPERSERVER 6028R-WTR(T) USER'S MANUAL 1-4 Contacting Supermicro Headquarters Address: Super Micro Computer , Inc. 980 Rock Ave. San Jose, CA 95131 U.S.A. T el: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Email: marketing@supermicro.com (General Information) support@supermicro.
Chapter 2: Server Installation 2-1 Chapter 2 Server Installation 2-1 Overview This chapter provides a quick setup checklist to get your SuperServer 6028R-WTR(T) up and running. Following these steps in the order given should enable you to have the system operational within a minimum amount of time.
2-2 SUPERSERVER 6027R-73DARF User's Manual Choosing a Setup Location • Leave enough clearance in front of the rack to enable you to open the front door completely (~25 inches) and approximately 30 inches of clearance in the back of the rack to allow for suf fi cient air fl ow and ease in servicing.
Chapter 2: Server Installation 2-3 Rack Mounting Considerations Warning! T o prevent bodily injury when mounting or servicing this unit in a rack, you must take special precautions to ensure that the system remains stable.
2-4 SUPERSERVER 6027R-73DARF User's Manual 2-4 Installing the System into a Rack This section provides information on installing the SC815 chassis into a rack unit with the quick-release rails provided. There are a variety of rack units on the market, which may mean the assembly procedure will differ slightly .
Chapter 2: Server Installation 2-5 Figure 2-1: Separating the Rack Rails Separating the Inner and Outer Rails 1. Locate the rail assembly in the chassis packaging. 2. Extend the rail assembly by pulling it outward. 3. Press the quick-release tab. 4. Separate the inner rail extension from the outer rail assembly .
2-6 SUPERSERVER 6027R-73DARF User's Manual Installing the Chassis into a Rack 1. Extend the outer rails as illustrated above. 2. Align the inner rails of the chassis with the outer rails on the rack. 3. Slide the inner rails into the outer rails, keeping the pressure even on both sides.
Chapter 3: System Interface 3-1 Chapter 3 System Interface 3-1 Overview There are several LEDs on the control panel as well as others on the drive carriers to keep you constantly informed of the overall status of the system and the activity and health of speci fi c components.
SUPERSERVER 6027R-73DARF User's Manual 3-2 1 3-3 Control Panel LEDs The control panel located on the front of the chassis has several LEDs. These LEDs provide you with critical information related to different parts of the system. This section explains what each LED indicates when illuminated and any corrective action you may need to take.
Chapter 3: System Interface 3-3 2 NIC2 Indicates network activity on the LAN2 port when fl ashing. HDD On the SuperServer 6028R-WTR(T), this LED indicates hard drive and/or DVD-ROM drive activity when fl ashing. Power Indicates power is being supplied to the system's power supply units.
SUPERSERVER 6027R-73DARF User's Manual 3-4 Notes.
4-1 Chapter 4: W arning Statements for AC Systems Chapter 4 Standardized W arning Statements for AC Systems 4-1 About Standardized W arning Statements The following statements are industry standard warnings, provided to warn the user of situations which have the potential for bodily injury .
4-2 SUPERSERVER 6028R-WTR(T) USER'S MANUAL W arnung WICHTIGE SICHERHEITSHINWEISE Dieses W arnsymbol bedeutet Gefahr . Sie be fi nden sich in einer Situation, die zu V erletzungen führen kann.
4-3 W arning Statements for AC Systems 안전을 위한 주의사항 경고! 이 경고 기호는 위험이 있음을 알려 줍니다. 작업자의 신체에 부상을 야기 할 수 있는 상태에 있게 됩니다.
4-4 SUPERSERVER 6028R-WTR(T) USER'S MANUAL Installation Instructions W arning! Read the installation instructions before connecting the system to the power source.
4-5 Chapter 4: W arning Statements for AC Systems Circuit Breaker W arning! This product relies on the building's installation for short-circuit (overcurrent) protection.
4-6 SUPERSERVER 6028R-WTR(T) USER'S MANUAL Power Disconnection W arning W arning! The system must be disconnected from all sources of power and the power cord removed from the power supply module(s) before accessing the chassis interior to install or remove system components.
4-7 Chapter 4: W arning Statements for AC Systems W arnung Das System muss von allen Quellen der Energie und vom Netzanschlusskabel getrennt sein, das von den Spg.V ersorgungsteilmodulen entfernt wird, bevor es auf den Chassisinnenraum zurückgreift, um Systemsbestandteile anzubringen oder zu entfernen.
4-8 SUPERSERVER 6028R-WTR(T) USER'S MANUAL Equipment Installation W arning! Only trained and quali fi ed personnel should be allowed to install, replace, or service this equipment.
4-9 Chapter 4: W arning Statements for AC Systems Restricted Area W arning! This unit is intended for installation in restricted access areas. A restricted access area can be accessed only through the use of a special tool, lock and key , or other means of security .
4-10 SUPERSERVER 6028R-WTR(T) USER'S MANUAL Battery Handling W arning! There is the danger of explosion if the battery is replaced incorrectly . Replace the battery only with the same or equivalent type recommended by the manufacturer .
4-1 1 Chapter 4: W arning Statements for AC Systems W arnung Bei Einsetzen einer falschen Batterie besteht Explosionsgefahr . Ersetzen Sie die Batterie nur durch den gleichen oder vom Hersteller empfohlenen Batterietyp. Entsorgen Sie die benutzten Batterien nach den Anweisungen des Herstellers.
4-12 SUPERSERVER 6028R-WTR(T) USER'S MANUAL Redundant Power Supplies W arning! This unit might have more than one power supply connection. All connections must be removed to de-energize the unit.
4-13 Chapter 4: W arning Statements for AC Systems Backplane V oltage W arning! Hazardous voltage or energy is present on the backplane when the system is operating.
4-14 SUPERSERVER 6028R-WTR(T) USER'S MANUAL Comply with Local and National Electrical Codes W arning! Installation of the equipment must comply with local and national electrical codes.
4-15 Chapter 4: W arning Statements for AC Systems Product Disposal W arning! Ultimate disposal of this product should be handled according to all national laws and regulations.
4-16 SUPERSERVER 6028R-WTR(T) USER'S MANUAL W arnung Die Entsorgung dieses Produkts sollte gemäß allen Bestimmungen und Gesetzen des Landes erfolgen. ¡Advertencia! Al deshacerse por completo de este producto debe seguir todas las leyes y reglamentos nacionales.
4-17 Chapter 4: W arning Statements for AC Systems ! הרהזא יקל ח תא םי רי סמ רשאכ שי . םידבוע ן יידע םיררווא מהו ןכתי , זראמהמ ררו ואמה ק.
4-18 SUPERSERVER 6028R-WTR(T) USER'S MANUAL Power Cable and AC Adapter W arning! When installing the product, use the provided or designated connection cables, power cables and AC adaptors. Using any other cables and adaptors could cause a malfunction or a fi re.
4-19 Chapter 4: W arning Statements for AC Systems ¡Advertencia! Al instalar el producto, utilice los cables de conexión previstos o designados, los cables y adaptadores de CA. La utilización de otros cables y adaptadores podría ocasionar un mal funcionamiento o un incendio.
4-20 SUPERSERVER 6028R-WTR(T) USER'S MANUAL W aarschuwing Bij het installeren van het product, gebruik de meegeleverde of aangewezen kabels, stroomkabels en adapters. Het gebruik van andere kabels en adapters kan leiden tot een storing of een brand.
Chapter 5: Advanced Serverboard Setup 5-1 Chapter 5 Advanced Serverboard Setup This chapter covers the steps required to connect the data and power cables and install add-on cards. All serverboard jumpers and connections are also described. A layout and quick reference chart are included in this chapter for your reference.
5-2 SUPERSERVER 6028R-WTR(T) USER'S MANUAL 5-2 Connecting Cables Now that the serverboard is installed, the next step is to connect the cables to the board. These include the data cables for the peripherals and control panel and the power cables.
Chapter 5: Advanced Serverboard Setup 5-3 Figure 5-1. Control Panel Header Pins Po we r Butto n OH/Fan Fail/ PWR Fail LED) 1 NIC1 Link LED Re s e t Butto n 2 Po we r Fail LED HDD LED FP PWRLED Rese t PWR 3.3 V UID LED Blue LED Cathode Gr ound Gr ound 19 20 3.
5-4 SUPERSERVER 6028R-WTR(T) USER'S MANUAL 5-3 Rear I/O Ports The I/O ports are in conformance with the PC 99 speci fi cation. See Figure 5-2 below for the locations of the various I/O ports. Figure 5-2. Rear I/O Ports Rear I/O Ports 1 VGA Port 2 USB 3.
Chapter 5: Advanced Serverboard Setup 5-5 1. There are two levers on the LGA201 1 socket. First press and release the load lever labeled 'Open 1st'. Installing an LGA 201 1 Processor 5-4 Installing the Processor and Heatsink Caution: When handling the processor package, avoid placing direct pressure on the label area of the fan.
5-6 SUPERSERVER 6028R-WTR(T) USER'S MANUAL 3. With the lever labeled 'Close 1 st' f u l l y r e tr a c t e d , g e n t l y p u s h d o w n on t he ' Op en 1st ' leve r to op en the load plate. Lif t the load plate t o o p e n i t co m p l e t e l y .
Chapter 5: Advanced Serverboard Setup 5-7 Caution: Y ou can only install the CPU to the socket in one direction. Make sure that the CPU is properly inserted into the socket before closing the load plate. If it doesn't close properly , do not force it as it may damage your CPU.
5-8 SUPERSERVER 6028R-WTR(T) USER'S MANUAL Installing a Passive CPU Heatsink 1. Do not apply any thermal grease to the two heatsinks or the CPU die -- the required amount has already been applied.
Chapter 5: Advanced Serverboard Setup 5-9 Removing the Heatsink W arning: We do not recommend that the CPU or the heatsink be removed. However , if you do need to uninstall the heatsink, please follow the instructions below to uninstall the heatsink to prevent damage done to the CPU or the CPU socket.
5-10 SUPERSERVER 6028R-WTR(T) USER'S MANUAL 5-5 Installing Memory Caution! Exercise extreme care when installing or removing DIMM modules to prevent any possible damage.
Chapter 5: Advanced Serverboard Setup 5-1 1 DIMM Module Population T able Follo w the t ables belo w when installing memor y . Processors and their Corresponding Memory Modules CPU# Corresponding DIMM.
5-12 SUPERSERVER 6028R-WTR(T) USER'S MANUAL Populating RDIMM/LRDIMM Memory Modules Intel E5-2600v3 Series Processor Memory Support T ype Ranks Per DIMM & Data Width DIMM Capacity (GB) Speed (MT/s), V oltage (V), Slot per Channel (SPC) and DIMM Per Channel (DPC) 1 Slot Per Channel 2 Slots Per Channel 1DPC 1DPC 2DPC 4Gb 8Gb 1.
Chapter 5: Advanced Serverboard Setup 5-13 5-6 Adding PCI Add-On Cards The 6028R-WTR(T) can accommodate up to six low-pro fi le add-on (expansion) cards. Installing an Add-on Card 1. Begin by removing the shield for the PCI slot you wish to populate.
5-14 SUPERSERVER 6028R-WTR(T) USER'S MANUAL Figure 5-5. X10DRW -i(T) Layout 5-7 Serverboard Details S-SGPIO I-SGPIO2 I-SGPIO1 JIPMB1 SAN MAC IPMI CODE JBA T1 JPWR1 S-SA T A1 S-SA T A0 S-SA T A3 S.
Chapter 5: Advanced Serverboard Setup 5-15 X10DRW -i(T) Jumpers Jumper Description Default Setting JBT1 Clear CMOS See Chapter 3 JI 2 C1/JI 2 C2 SMB to PCI-E slots Pins 2-3 (Disabled) JPB1 BMC Enable .
5-16 SUPERSERVER 6028R-WTR(T) USER'S MANUAL Connectors Description S-SGPIO Seria_Link General-Purpose (SGPIO) I/O header for S-SA T A connections 0-3 SP1 Internal speaker/buzzer SXB1A SMC-proprietary SPEC slot (Left) (See Note 2 below .) SXB1B (CPU1/CPU2) PCI-E 3.
Chapter 5: Advanced Serverboard Setup 5-17 5-8 Connector De fi nitions Power Connectors A 24-pin main power supply connector (JPWR1), and two 8-pin CPU power connectors (JPWR2/JPWR3) are located on the serverboard.
5-18 SUPERSERVER 6028R-WTR(T) USER'S MANUAL NIC1/NIC2 LED Indicators The NIC (Network Interface Controller) LED connection for LAN Port 1 is located on pins 1 1 and 12 of JF1, and for LAN Port 2 is on pins 9 and 10. Attach the NIC LED cables here to display network activity .
Chapter 5: Advanced Serverboard Setup 5-19 Power LED Th e Power LED c o nne ct io n is lo c ated on pins 1 5 and 1 6 of JF 1 . Ref er t o t he ta ble o n th e ri ght f or pi n de fi nit ions. Power LED Pin De fi nitions (JF1) Pin# De fi nition 15 3.
5-20 SUPERSERVER 6028R-WTR(T) USER'S MANUAL Universal Serial Bus (USB) Four USB 3.0 ports (USB 0/1, USB 2/3) are located on the I/O backpanel. In addition, an internal USB header , located next to S-SA T A0, also provides two USB 3.0 connections (USB 4/5) for front panel support.
Chapter 5: Advanced Serverboard Setup 5-21 Unit Identi fi er Switch/UID LED Indicator A Unit Identi fi er (UID) switch is located on the I/O backplane, and two UID LED indicators are located on the serverboard. The rear UID LED (LED1) is located next to the UID switch.
5-22 SUPERSERVER 6028R-WTR(T) USER'S MANUAL S-SGPIO and I-SGPIO 1/2 Headers Three SGPIO (Serial Link General Purpose Input/Output) headers are located on the serverboard. I-SGPIO 1 supports I-SA T A 0-3, and I-SGPIO 2 supports I-SA T A 4/5. S-SGPIO is used for S-SA T A 0-3.
Chapter 5: Advanced Serverboard Setup 5-23 5-9 Jumper Settings Explanation of Jumpers T o modify the operation of the serverboard, jumpers can be used to choose between optional settings. Jumpers create shorts between two pins to change the function of the connector .
5-24 SUPERSERVER 6028R-WTR(T) USER'S MANUAL W atch Dog Enable/Disable Jumper Settings (JWD1) Jumper Setting De fi nition Pins 1-2 Reset Pins 2-3 NMI Open Disabled VGA Enable/Disable Jumper Setti.
Chapter 5: Advanced Serverboard Setup 5-25 I 2 C to PCI-E Jumper Setting Jumper Setting De fi nition Pins 1-2 Enabled Pins 2-3 Disabled (Default) ME Mode Select Jumper Settings Jumper Setting De fi .
5-26 SUPERSERVER 6028R-WTR(T) USER'S MANUAL IPMI Dedicated LAN LEDs In addition to LAN 1/LAN 2, an IPMI- dedicated LAN is located on the I/O Backplane of the serverboard. The amb er LED o n th e ri ght in dic ate s ac tiv it y , w hil e the g re en LED o n th e lef t in dic ate s the s pee d of th e c onn ec ti on.
Chapter 5: Advanced Serverboard Setup 5-27 Onboard Power LED An Onboard Power LED is located at LED2 on the serverboard. When this LED is on, the system is on. Be sure to turn off the system and unplug the power cord before removing or installing components.
5-28 SUPERSERVER 6028R-WTR(T) USER'S MANUAL Figure 5-6. Driver/T ool Installation Display Screen 5-12 Installing Software The Supermicro ftp site contains drivers and utilities for your system at ftp://ftp. supermicro.com . Some of these must be installed, such as the chipset driver .
Chapter 5: Advanced Serverboard Setup 5-29 Note: Click the icons showing a hand writing on paper to view the readme fi les for each item. Click the computer icons to the right of these items to install each item (from top to the bottom) one at a time.
5-30 SUPERSERVER 6028R-WTR(T) USER'S MANUAL Figure 5-8. SuperDoctor 5 Interface Display Screen (Remote Control) Note: The SuperDoctor 5 program and User ’ s Manual can be downloaded from the Supermicro web site at http://www .supermicro.com/products/nfo/sms_sd5.
Chapter 5: Advanced Serverboard Setup 5-31 5-13 Serverboard Battery Caution : There is a danger of explosion if the onboard battery is installed upside down, which will reverse its polarites (see Figure 5-x). This battery must be replaced only with the same or an equivalent type recommended by the manufacturer (CR2032).
5-32 SUPERSERVER 6028R-WTR(T) USER'S MANUAL Notes.
Chapter 6: Advanced Chassis Setup 6-1 Chapter 6 Advanced Chassis Setup This chapter covers the steps required to install components and perform maintenance on the SC815TS-R740WBP chassis. For component installation, follow the steps in the order given to eliminate the most common problems encountered.
6-2 SUPERSERVER 6027R-73DARF User's Manual 6-2 Control Panel The control panel (located on the front of the chassis) must be connected to the JF1 connector on the serverboard to provide you with system status indications. A ribbon cable has bundled these wires together to simplify the connection.
Chapter 6: Advanced Chassis Setup 6-3 The fans in the system are redundant, hot-plug. Replacing System Fans Removing a Fan 1. Remove the chassis cover . 2. Press the tabs on the sides of the fan to unlock and remove the fan and its housing. The fan's power connections will automatically detach.
6-4 SUPERSERVER 6027R-73DARF User's Manual 6-4 Drive Bay Installation/Removal Accessing the Drive Bays SAS/SA T A Drives: Y ou do not need to access the inside of the chassis or remove power to replace or swap SAS/SA T A drives. Proceed to the next step for instructions.
Chapter 6: Advanced Chassis Setup 6-5 Figure 6-3. Removing a Drive Carrier Release Button Handle Caution: Regardless of how many hard drives are installed, all drive carriers must remain in the drive bays to maintain proper air fl ow . Use caution when working around the backplane.
6-6 SUPERSERVER 6027R-73DARF User's Manual DVD-ROM Installation (Optional) The top cover of the chassis must be opened to gain full access to the DVD-ROM drive bay . The SuperServer 6028R-WTR(T) accomodates only slim type DVD-ROM drives. Side mounting brackets are typically needed to mount a slim DVD-ROM drive in the server .
Chapter 6: Advanced Chassis Setup 6-7 6-5 Power Supply The SuperServer 6028R-WTR(T) has a 740 W att redundant power supply consisting of two power modules. Each power supply module has an auto-switching capability , which enables it to automatically sense and operate at a 100V - 240V input voltage.
6-8 SUPERSERVER 6027R-73DARF User's Manual Notes.
Chapter 7: BIOS 7-1 Chapter 7 BIOS 7-1 Introduction This chapter describes the AMI BIOS Setup utility for the X10DRW -i(T) It also provides the instructions on how to navigate the AMI BIOS Setup utility screens. The AMI ROM BIOS is stored in a Flash EEPROM and can be easily updated.
7-2 SUPERSERVER 6028R-WTR(T) USER'S MANUAL How T o Change the Con fi guration Data The con fi guration data that determines the system parameters may be changed by entering the AMI BIOS Setup utility . This Setup utility can be accessed by pressing <Delete> at the appropriate time during system boot.
Chapter 7: BIOS 7-3 Memory Information T otal Memory This displays the amount of memory that is available in the system. 7-3 Advanced Setup Con fi gurations Use the arrow keys to select Advanced and .
7-4 SUPERSERVER 6028R-WTR(T) USER'S MANUAL Bootup Num-Lock Use this feature to set the Power-on state for the Numlock key . The options are Off and On . W ait For 'F1' If Error If this f eature is set to Enabled , th e syste m wil l wait u ntil t he ' F 1' ke y i s pr es sed wh en an e rr or o cc ur s.
Chapter 7: BIOS 7-5 CPU Con fi guration This submenu displays the information of the CPU as detected by the BIOS. It also allows the user to con fi gure the CPU settings. Socket 1 CPU Information/Socket 2 CPU Information This submenu displays the following information regarding the CPU installed in Socket 1 or Socket 2.
7-6 SUPERSERVER 6028R-WTR(T) USER'S MANUAL RTID (Record T ypes IDs) This feature displays the total number of Record T ype IDs for local and remote pools. The options are Optimal and Alternate. Hyper-threading Select Enabled to support Intel Hyper-threading T echnology to enhance CPU performance.
Chapter 7: BIOS 7-7 DCU Streamer Prefetcher (A vailable when supported by the CPU) Select Enabled to support Data Cache Unite (DCU) prefetch to speed up data accessing and processing in the DCU to enhance CPU performance. The options are Disabled and Enabled .
7-8 SUPERSERVER 6028R-WTR(T) USER'S MANUAL C1E Support (A vailable when Power T echnology is set to Custom) Select Enabled to enable Enhanced C1 Power State to boost system performance.
Chapter 7: BIOS 7-9 Long Duration Maintained This item displays the period of time (in seconds) during which long duration power is maintained. The default setting is 0 . Recommended Short Duration Power Limit This item displays the short duration power settings (in watts) recommended by the manufacturer .
7-10 SUPERSERVER 6028R-WTR(T) USER'S MANUAL Intel ® I/OA T Select Enabled to enable Intel I/OA T (I/O Acceleration T echnology), which will significantly reduce CPU overhead by leveraging CPU architectural improvements and freeing the system resource up for other tasks.
Chapter 7: BIOS 7-1 1 QPI (Quick Path Interconnect) Link Speed Mode Use this feature to select data transfer speed for QPI Link connections. The options are Fast and Slow . QPI Link Frequency Select Use this feature to select the desired QPI frequency .
7-12 SUPERSERVER 6028R-WTR(T) USER'S MANUAL Channel Interleaving This feature selects from the different channel interleaving methods. The options are Auto , 1 Way , 2 W ay , 3, W ay , and 4 W ay . Rank Interleaving This feature allows the user to select a rank memory interleaving method.
Chapter 7: BIOS 7-13 South Bridge This feature allows the user to con fi gure the settings for the Intel PCH chip. PCH Information This feature displays the following PCH information. Name : This item displays the name of the PCH chip. Stepping : This item displays the PCH stepping.
7-14 SUPERSERVER 6028R-WTR(T) USER'S MANUAL SA T A Con fi guration When this submenu is selected, the AMI BIOS automatically detects the presence of IDE or SA T A devices and displays the following items. SA T A Port0~SA T A Port5 : The AMI BIOS displays the status of each SA T A port as detected by the BIOS.
Chapter 7: BIOS 7-15 SA T A RAID Option ROM/UEFI Driver Select Enabled to boot the system from a SA T A RAID device or a UEFI (Uni fi ed Extensible Firmware Interface) device. The options are Enabled or Disabled. Port 0~5 Hot Plug Select Enabled to enable hot-plug support for a port speci fi ed by the user .
7-16 SUPERSERVER 6028R-WTR(T) USER'S MANUAL ASPM Support This feature allows the user to set the Active State Power Management (ASPM) level for a PCI-E device. Select Auto to allow the system BIOS to automatically set the ASPM level for the system.
Chapter 7: BIOS 7-17 Super IO Con fi guration Super IO Chip Displays the Super IO chip type. COM 1 Con fi guration Serial Port Select Enabled to enable a serial port speci fi ed by the user . The options are Enabled and Disabled. Device Settings This item displays the settings of Serial Port 1.
7-18 SUPERSERVER 6028R-WTR(T) USER'S MANUAL SOL (Serial_Over_LAN) Device Mode Use this feature to select the desired mode for the SOL port. The options are Normal and High Speed. Serial Port 2 Attribute Use this feature to select the attribute for serial port 2.
Chapter 7: BIOS 7-19 Data Bits Use this feature to set the data transmission size for Console Redirection. The options are 7 and 8 (Bits). Parity A parity bit can be sent along with regular data bits to detect data transmission errors. Select Even if the parity bit is set to 0, and the number of 1's in data bits is even.
7-20 SUPERSERVER 6028R-WTR(T) USER'S MANUAL Putty Keypad Use this feature to select function key and keypad setting on Putty . The options are VT100 , LINUX, XTERMR6, SCO, ESCN, and VT400.
Chapter 7: BIOS 7-21 Flow Control This feature allows the user to set the fl ow control for Console Redirection to prevent data loss caused by buffer over fl ow . Send a "Stop" signal to stop sending data when the receiving buffer is full.
7-22 SUPERSERVER 6028R-WTR(T) USER'S MANUAL High Precision Event Timer Select Enabled to activate the High Precision Event Timer (HPET) that produces periodic interrupts at a much higher frequenc.
Chapter 7: BIOS 7-23 Intel TXT(L T -SX) Con fi guration This feature indicates if the following hardware components support the Intel TXT (T rusted Execution T echnology), which helps protect against software-based attacks and ensures protection, con fi dentiality and integrity of data stored or created on the system.
7-24 SUPERSERVER 6028R-WTR(T) USER'S MANUAL Runtime Error Logging Support Change this item to enable or disable runtime error logging. The options are Enabled and Disabled. Memory Correction Error Threshold Change this item to de fi ne the system's memory correction error threshold.
Chapter 7: BIOS 7-25 7-5 IPMI Use this menu to con fi gure Intelligent Platform Management Interface (IPMI) settings. System Event Log Enabling/Disabling Options SEL Components Select Enabled for all system event logging at bootup. The options are Enabled and Disabled.
7-26 SUPERSERVER 6028R-WTR(T) USER'S MANUAL When SEL is Full This feature allows the user to decide what the BIOS should do when the system event log is full. Select Erase Immediately to erase all events in the log when the system event log is full.
Chapter 7: BIOS 7-27 7-6 Boot Th is m enu all ows the us er to con fi gure t he fo llow in g bo ot set ti ngs f or t he syst em. Set Boot Prioriti es 1 st Boot De vic e/2nd Boot D evice/3rd Boot Devi.
7-28 SUPERSERVER 6028R-WTR(T) USER'S MANUAL USB Hard Disk Drive BBS Priorities This submenu allows the user to specify the boot priority sequence of a USB hard drive. 1st Device Network Device BBS Priorities This submenu allows the user to specify the boot priority sequence of a network device.
Chapter 7: BIOS 7-29 Pas sword Ch ec k This item allows you to decide when the system should check for a password after it has been entered. Select Setup for the system to prompt for a password before the user enters the BIOS Setup utility .
7-30 SUPERSERVER 6028R-WTR(T) USER'S MANUAL Save Changes and Reset When you have completed the system con fi guration changes, select this option to save the changes and reboot the computer so that the new system con fi guration settings can take effect.
Chapter 7: BIOS 7-31 Boot Override This feature allows the user to override the Boot Option Priorities setting in the Boot menu, and instead immediately boot the system with one of the listed devices.
7-32 SUPERSERVER 6028R-WTR(T) USER'S MANUAL Notes.
A-1 Appendix A: BIOS POST Error Codes Appendix A BIOS Error Beep Codes During the POST (Power-On Self-T est) routines, which are performed at each system boot, errors may occur . Non-fatal errors are those which, in most cases, allow the system to continue to boot.
A-2 SUPERSERVER 6028R-WTR(T) USER'S MANUAL Notes.
B-1 Appendix B: System Speci fi cations Appendix B System Speci fi cations Processors Single or dual Intel® Xeon E5-2600v3 Series processors. Note: If using a single processor only , then slots SXB1B and SXB2 (lower left) will NOT be functional Note: Please refer to our web site for a complete listing of supported processors.
B-2 S UPER S ERVER 6027R-73DARF User's Manual Weight 57 lbs. (25.9 kg.) System Cooling Three 8-cm system cooling fans Note: The system cooling fans are redundant, hot-plug. System Input Requirements AC Input V oltage: 100 - 240V AC auto-range Rated Input Current: 9 - 3.
B-3 Appendix B: System Speci fi cations Notes.
B-4 S UPER S ERVER 6027R-73DARF User's Manual (continued from front) The products sold by Supermicro are not intended for and will not be used in life support systems, medical equipment, nuclear .
デバイスSupermicro SuperServer 6028R-WTRTの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Supermicro SuperServer 6028R-WTRTをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはSupermicro SuperServer 6028R-WTRTの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Supermicro SuperServer 6028R-WTRTの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Supermicro SuperServer 6028R-WTRTで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Supermicro SuperServer 6028R-WTRTを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はSupermicro SuperServer 6028R-WTRTの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Supermicro SuperServer 6028R-WTRTに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちSupermicro SuperServer 6028R-WTRTデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。