i TELEDYNE ELECTRONIC TECHNOLOGIES Analytical Instruments TED ' P ORT ABLE O XYGEN M ONIT OR I NSTRUCTION M ANUAL TYPE B EQUIPMENT: Equipment providing a particular degree of protec- tion against electric shock, particularly regarding— • allowable LEAKAGE CURRENT • Reliability of the protective earth connection (if present).
2 TELEDYNE ELECTRONIC TECH NOLOGIES Analytical Instruments C OPYRIGHT © 1996 T ELEDYNE E LECTRONIC TECHNOLOGIES – A NAL YTICA L I NSTRUM ENTS A ll Rights Reserved No par t of this m anual may be re.
3 TELEDYNE ELECTRONIC TECH NOLOGIES Analytical Instruments T AB L E O F C ONTENTS S ECTION T OPIC P AG E N UMBER I NTRODUCTION 4 A PPLICA TION S 5 D ESCRI PTIONS O F F UNCTIONAL Z ONES : F RONT P ANEL 6 R EAR P AN EL 7 1. O PER ATION S : 1.1 S ET - UP 8 1.
4 TELEDYNE ELECTRONIC TECH NOLOGIES Analytical Instruments I NTRODUCTION The T ED 191 Portab le Ox ygen Monitor is a n eas y-to-use , port able instrum ent that pro vides f ast and accurate ox ygen m onitoring and aud io-vis ual alarm capabi lity.
5 TELEDYNE ELECTRONIC TECH NOLOGIES Analytical Instruments A PPLICA TIONS The ins trum ent is desi gned f or the m easur em ent of ox ygen conc entra tions in a variet y of m edical gas m ixtures .
6 TELEDYNE ELECTRONIC TECH NOLOGIES Analytical Instruments 21 30 40 50 60 70 80 90 102 21 30 40 50 60 70 80 90 102 LO HI X 21 TELEDYNE % OXYGEN OXYGEN M ONIT OR I O D ES CRIPT ION OF F UNCTIONAL Z ONES F RONT P AN E L On / Of f Sw itch Allows th e operat or to t urn the i nstrum ent on a nd of f.
7 TELEDYNE ELECTRONIC TECH NOLOGIES Analytical Instruments D ES CRIPT ION OF F UNCTIONAL Z ONES R EA R P ANE L Battery Drawer The Batter y Drawer cont ains 4 x AA (P enlight) batteri es required to power the ins trum ent. Sensor Cable Connector Plug The Oxygen Sensor Con nector C able is plugg ed into this “one way” sock et.
8 TELEDYNE ELECTRONIC TECH NOLOGIES Analytical Instruments S ECT ION O NE O PERATIONS Note : Upon receip t, inspect the entir e unit and ac com panying acc essor ies for dam age or brok en or loose parts. If dam aged, do not use. Notif y t he Shippe r, a nd c onsult Tele dyne Electro nic T echno logies Anal ytical Inst ruments 1.
9 TELEDYNE ELECTRONIC TECH NOLOGIES Analytical Instruments O PERATIONS 1.2 I NSTA LL ING TH E BA TTERIE S W ithdraw the battery drawer fr om the monitor casing, by grasp ing the s ide lugs loca ted on either s ide of the batter y dra wer, and , firm ly pinch ing them inwards , s im ultaneousl y pu ll th e drawer o utwards.
10 TELEDYNE ELECTRONIC TECH NOLOGIES Analytical Instruments O PERATIONS 1.3 I NSTALLING THE O XYGEN SENSOR The T- 7 Ox ygen Sensor m ust be insta lled bef ore the instrum ent c an be use d. Ensure t hat the m onit or is s witched off . Remove the s ens or fr om its pr otective bag.
11 TELEDYNE ELECTRONIC TECH NOLOGIES Analytical Instruments O PERATIONS 1.4 C AL IBRA TE THE I NSTRUMENT Calibration shou ld be ef fec ted at le ast once per sh ift, and alwa ys prior t o the use of the instrum ent. Note: Never expos e the se nsor to v aryi ng temp eratures w hile c alibr ating ( i.
12 TELEDYNE ELECTRONIC TECH NOLOGIES Analytical Instruments O PERATIONS 1.5 N ORM AL O PERATION Switch the instrum ent o n usi ng the On –Of f Switch . Validate the ca librat ion of the instrum ent by ex posing t he ox ygen sensor to room air , and verif ying that the displa y on the instrum ent reads 100% (± 2 %).
13 TELEDYNE ELECTRONIC TECH NOLOGIES Analytical Instruments O PERATIONS 1.6 S ET THE A LA RMS The lines in dicating the 100% gradua tions ar ound t he Hig h and L ow Al arm Settings Knobs are onl y intended as gu ides, an d not as prec ise sett ings.
14 TELEDYNE ELECTRONIC TECH NOLOGIES Analytical Instruments S ECT ION T WO A NAESTHETIC A GENTS 2. A N AESTHETIC A GENTS The anaes thetic agents listed in the f ollow ing ta ble (Halo thane, Enf lur ane, Is oflur ane Sev ofl urane, and Desflur ane) were vap orised int o a stream of 30%ox ygen / 70% n itrous oxide.
15 TELEDYNE ELECTRONIC TECH NOLOGIES Analytical Instruments S ECT ION T HREE C LEA NING A ND S TERI L IS ATION 3.1 C LEANING T HE TED 191 P ORTABLE O XYGEN M ONIT OR The instrum ent itself shou ld be cl eaned using a d am p cloth.
16 TELEDYNE ELECTRONIC TECH NOLOGIES Analytical Instruments S ECT ION F OU R D O ’ S A ND D ON ’ TS D O ’ S ; Read the O perator s Manual thor oughl y before us ing the instr um ent. ; Calibrate onc e per s hif t, and prior to e ach and e ver y use.
17 TELEDYNE ELECTRONIC TECH NOLOGIES Analytical Instruments S ECT ION F IV E R OU TIN E M A INTE NA NCE 5.1 R OUTIN E V ISU AL I NSPECTION Always ins pect t he instr um ent prior to us e f or obvio us dam age or f or parts or com ponents miss ing.
18 TELEDYNE ELECTRONIC TECH NOLOGIES Analytical Instruments S ECT ION S IX T RO UBLESHOOTING S YMP TOM C URE / R EM ARK No numer ic disp la y on the LCD when powered on 1) Check batter y drawer is proper ly locate d.
19 TELEDYNE ELECTRONIC TECH NOLOGIES Analytical Instruments T ROUBLESHOOTING S YMP TOM C URE / R EM ARK The dis played rea dings are unsta ble 1) Rem ove the sens or tip f rom the T-adaptor , unsc rew th e “flo w diverter” and g entl y swab an y exces s m oisture of f the s ensor c ell mem brane, then f low dr y gas over th e m embrane.
20 TELEDYNE ELECTRONIC TECH NOLOGIES Analytical Instruments S ECT ION S EVEN T ECHNICAL S PE CIFICA TIONS SA FE TY CLASSI FICATION Complies to IEC 601 – Safety of Medical Eq uipm ent Internall y pow.
21 TELEDYNE ELECTRONIC TECH NOLOGIES Analytical Instruments T ECHNIC AL S PE CIFIC ATION S SENSO R RES PON SE TI ME Less than 6 secon ds to 90% of f inal m easured v alue in r espons e to a step ch ange in th e actu al ox ygen co ncentrat ion be ing m easured.
22 TELEDYNE ELECTRONIC TECH NOLOGIES Analytical Instruments S ECT ION E IGHT E FFECT OF P RESSURE Virtual ly all gas sens ors and anal ysers m eas ure the part ial pr essure, no t the per cent age, of the gas that they sens e.
23 TELEDYNE ELECTRONIC TECH NOLOGIES Analytical Instruments S ECT ION N IN E E FFECT OF H UMID ITY Humidit y does not directl y affect the accurac y of the sensor's m eas urement. Ho wever, whe n a nebuliser or oth er de vice is used t o inc rease m ois ture le vels i n gas m ixtur es, the m oistur e actua ll y dilutes t he m ixture.
24 TELEDYNE ELECTRONIC TECH NOLOGIES Analytical Instruments S ECT ION T E N E FFECT OF T EMPERATURE The T eledyne E lectron ic T echnolog ies Anal ytical Int ruments sens ors adjus t for ambient tem per ature changes in the ra nge of 0 - 40 ºC (32 - 10 6ºF).
25 TELEDYNE ELECTRONIC TECH NOLOGIES Analytical Instruments S ECT ION E LEVEN D ISCREPANCY IN R EADINGS The T ED 191 is intend ed to be used as a secondary oxygen monitor , meani ng that it is int ended to verif y the accur acy of and chec k the oxygen co ncentrat ion l eaving a nother ox ygen m ixing device or prim ar y life support s ystem (i.
26 TELEDYNE ELECTRONIC TECH NOLOGIES Analytical Instruments S ECT ION T WELVE R EPAIR S ERVICE In the even t that your TED 1 91 Porta ble O xygen Monitor re quir es servic e, th e followi ng s teps wi.
27 TELEDYNE ELECTRONIC TECH NOLOGIES Analytical Instruments S ENSOR C ELL R EPLACEMENT L OG D AT E W AR R AN T Y ?S ERIAL N UMBER R EM ARKS N/A MANUFACT URED.
28 TELEDYNE ELECTRONIC TECH NOLOGIES Analytical Instruments T ECHNIC AL S ERVICE L OG D AT E W AR R AN T Y ?D ETA ILS R EM ARKS.
29 TELEDYNE ELECTRONIC TECH NOLOGIES Analytical Instruments G ENERAL N OTES.
30 TELEDYNE ELECTRONIC TECH NOLOGIES Analytical Instruments S PA RE P AR T S L IST S PA RE P ARTS P AR T N UM BER D ESCRIPT ION A51327 Micro-F uel Cell T-7 with f low diverter P/N A5 0057 C885 Cable a.
デバイスTeledyne TED 191の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Teledyne TED 191をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはTeledyne TED 191の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Teledyne TED 191の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Teledyne TED 191で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Teledyne TED 191を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はTeledyne TED 191の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Teledyne TED 191に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちTeledyne TED 191デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。