ToaメーカーDA-250DH CUの使用説明書/サービス説明書
ページ先へ移動 of 20
DUAL POWER AMPLIFIERS DA-250D CU DA-250DH CU Thank you for purchasing TOA's Dual Power Amplifier. Please carefully follow the instructions in this manual to ensure long, trouble-free use of your equipment.
2 T ABLE OF CONTENTS 1. IMPORT ANT SAFETY INSTRUCTIONS .................................................... 3 2. SAFETY PRECAUTIONS ............................................................................... 4 3. GENERAL DESCRIPTION ..............
3 1. IMPORT ANT SAFETY INSTRUCTIONS • Read these instructions. • Keep these instructions. • Heed all warnings. • Follow all instructions. • Do not use this apparatus near water. • Clean only with dry cloth. • Do not block any ventilation openings.
4 When Installing the Unit • Do not expose the unit to rain or an environment where it may be splashed by water or other liquids, as doing so may result in fire or electric shock. • Use the unit only with the voltage specified on the unit. Using a voltage higher than that which is specified may result in fire or electric shock.
5 • When moving the unit, be sure to remove its power supply cord from the wall outlet. Moving the unit with the power cord connected to the outlet may cause damage to the power cord, resulting in fire or electric shock. When removing the power cord, be sure to hold its plug to pull.
6 3. GENERAL DESCRIPTION TOA's DA-250D and DA-250DH Dual Power Amplifiers feature high power handling capabilities and durability. The DA-250D is configured with 250 W x 2 channels (4 Ω output) and 170 W x 2 channels (8 Ω output), and the DA-250DH features a 250 W x 2 channels (19.
Rack mounting screws are not supplied with the unit. Be sure to use the screws with a diameter of over 5 mm (0.2") and length of over 12 mm (0.47") to mount the unit. Failure to do so may cause personal injury. CAUTION 6. INST ALLA TION PRECAUTIONS 7 • The supplied power supply cord is designed for exclusive use with this unit.
8 1. Power switch [ ON / OFF] Power is switched on and off with each depression of this switch. 2. Power indicator [POWER] Lights blue when the power is switched on. 3. Input level controls [CH 1/BRIDGE, CH 2] Adjust the input level of each channel. 4.
9 [Rear] 6 7 9 10 11 DA-250D DA-250DH 8 6 7 9 10 11 8 6. AC inlet Connect the supplied power cord to this inlet. 7. Functional ground terminal [SIGNAL GND] Hum noise may be generated when external equipment is connected to the unit. Connecting this terminal to the functional ground terminal of the external equipment may reduce the hum noise.
10 Step 1. Switch off the unit's power. Step 2. Set the BRIDGE ON/OFF switch and CH 1 mode ON/OFF switch. Step 3. Connect the sound source equipment to the Input terminals. Note: Refer to p. 12 for the removable terminal plug connection. Step 4. Connect speakers to the Speaker output terminals.
11 CH2 CH1 Speaker output terminals Switch BRIDGE CH 1 mode OFF OFF Setting 4 – 8 Ω 4 – 8 Ω 19.6 Ω 19.6 Ω CH1 CH1 CH2 CH2 DA-250D DA-250DH [2 inputs - 2 outputs] (factory-preset) Speaker output terminals Switch BRIDGE CH 1 mode ON OFF Setting 8 Ω 39.
Cable end treatment 12 Connector connections Step 1. Loosen the terminal screw, then insert the cable. Step 2. Retighten the terminal screw. (Pull on the cable to ensure it is securely connected.) Tip Recommended slotted screwdriver type: Screwdriver with blade that is 3 mm (0.
13 The Input sensitivity can be set to +4 dB (factory-preset) or -10 dB for each channel. Besides, only the DA-250DH employs the High-pass filter on each channel, which can be set to "ON" or "OFF." Step 1. Unscrew 7 screws securing the top cover of the unit, then detach it.
14 1 1. PROTECTION OPERA TION LIST Failure Protection Operation Indicator Remedy Recovery Overcurrent due to overload Current limiter activated when impedance drops below the specified value. Peak indicator lights. Remove overload. Connecting a correct load automatically restores normal operation.
15 13. CLEANING THE FIL TER Step 1. Switch off the unit's power. Step 2. Remove the ventilation panel as shown in the figure. Step 3. Detach the filter inside the ventilation panel. Step 4. Clear the filter of dust. Step 5. Replace the filter and ventilation panel.
16 H C CH 1 INPUT E H C CH 2 INPUT E Current Limiter Short Detector Protection Circuit OUTPUT 1 relay CH 1 OUTPUT CH 2 OUTPUT +4 dB - 10 dB CH 1 sensitivity selection jumper (+4 dB/ - 10 dB) CH 1 inpu.
17 15. DIMENSIONAL DIAGRAM Unit: mm (inches) 401.8 (15.82) 371 (14.61) 22.5 (0.89) 482 (18.98) 465 (18.31) 442 (17.4) 31.8 (1.25) 44 (1.73).
18 * 0 dB = 0.775 V Note: The design and specifications are subject to change without notice for improvement. Power cord (2 m) ................................................................. 1 Removable terminal plug (3 pins) .......................
19 * 0 dB = 0.775 V Note: The design and specifications are subject to change without notice for improvement. Power cord (2 m) ................................................................. 1 Removable terminal plug (3 pins) .......................
133-22-125-50 URL: http://www.toa.jp/.
デバイスToa DA-250DH CUの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Toa DA-250DH CUをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはToa DA-250DH CUの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Toa DA-250DH CUの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Toa DA-250DH CUで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Toa DA-250DH CUを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はToa DA-250DH CUの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Toa DA-250DH CUに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちToa DA-250DH CUデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。