ELECTRONIC AIR CLEANER LIMITED THREE-YEAR W ARRANTY This limited warranty covers T rion Residential T ype Electronic Air Cleaners, excluding ductwork, wiring and installation. T rion warrants that all new T rion Electronic Residential Air Cleaners are free from defects in material and workmanship under normal, noncommercial use and service.
Power T ray Assembly 120/50-60/1 Power T ray Assembly 240/50-60/1 High Frequency Power Supply* Electronic Air Flow Sensor* On/Off switch* Interlock Switch* Cabinet Assembly Pre-Filter (2 req.) Cell, Ionizing-Collecting (2 req.) Ionizing Wire Assembly Front Panel Assembly Contact Board Assembly (2 req.
10. If no voltage is present, remove the second cell. Install cell number one and measure voltage as described in step #7. If voltage is present, the second cell, which is now out of the cabinet, is shorted. Refer to COMMON TROUBLESHOOTING TECHNIQUES (pg.
SECONDAR Y CIRCUIT POWER SUPPL Y If the Red CELL ENERGIZED light remains out with the Ionizing-Collecting Cells removed from the cabinet, the power supply is defective. Specific problems in the Power T ray Assembly can be isolated by using a Multimeter and High V oltage Probe to check the output voltages.
SECONDAR Y CIRCUIT IONIZING-COLLECTING CELL The cells are electrically energized through a contact terminal located at the top center of each cell. The ionizing wires and alternating collector plates are electrically charged while the interleaving plates are grounded.
PRIMAR Y CIRCUIT WITH HV AC SYSTEM BLOWER OPERA TING • If there is no supply line voltage at the transformer input connections, correct the fault at the dedicated power source or HV AC system power source.
TROUBLESHOOTING W ARNING: • These procedures must be performed by a qualified HV AC technician or electrician. • Risk of personal injury or death could occur by attempting to troubleshoot or r epair this unit by untrained persons. • Exercise the usual pr ecautions when working with high voltage.
SYSTEM CHECKOUT W ARNING: The following procedur es must be conducted by a qualified HV AC contractor or repair person ONL Y . These procedur es will expose hazardous electrically energized charged components. Disconnect power between checks and proceed car efully .
ELECTRICAL INST ALLA TION CAUTION : If the Electronic Air Cleaner is wir ed directly to the integrated accessory control on the furnace, it is imperative that the ampere rating of the contr ol be sufficient to handle the curr ent requir ed by the air cleaner .
NOTE: The following is a typical installation of the air cleaner on a highboy furnace. Y ou may have to alter the installation to fit your particular application. 1. Locate the cabinet in the cold air return duct such that all of the return air flows through the unit.
INST ALLA TION CAUTION: Only a trained, experienced servicer should install this Electronic Air Cleaner . The Front Panel Assembly , Power T ray Assembly , Ionizing-Collecting Cells and Pre-filters should be r emoved befor e installation. T o remove the Power T ray Assembly , remove the two (2) screws fr om inside the top front of the cabinet.
Installation 15 EAC20002025 EAC14001625 EAC14002020 Unit Dimensions 10 For Qualified HV AC Installer Only TYPICAL MOUNTING POSITIONS (Air cleaner shown shaded in illustrations) Horizontal Furnace – Mounted vertically in return duct as close to the furnace as possible.
LOCA TION SELECTION Remember to select a location that is readily accessible for periodic inspection and cleaning of the the Pre- filters and Ionizing-Collecting Cells. Allow a minimum of 24” clearance in front and 12” clearance above the air cleaner for component removal and service space.
Atomizing Humidifiers If an atomizing humidifier is mounted upstream of the air cleaner: 1. Mount the humidifier as far upstream in the ductwork as possible. A distance of at least 10 feet is recommended to reduce the possibility of excessive arcing as water droplets pass through the Electronic Air Cleaner .
デバイスTrion HE Plus 2000の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Trion HE Plus 2000をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはTrion HE Plus 2000の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Trion HE Plus 2000の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Trion HE Plus 2000で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Trion HE Plus 2000を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はTrion HE Plus 2000の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Trion HE Plus 2000に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちTrion HE Plus 2000デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。