VantecメーカーUGT-IS602Rの使用説明書/サービス説明書
ページ先へ移動 of 36
2+1 SA T A 6G & P A T A PCI-E COMBO HOST CARD WITH RAID User Manual Model: UGT -IS602R All brand n ames and t rademarks are propert ies of thei r r espectiv e owners.
UGT ‐IS602R P a g e 2 Features and Benefit s z PCI-Express 2.0 x 1 (Compatible with PCI-Expres s 1.0) z Supports communication speeds of 6.
UGT ‐IS602R P a g e 3 Specifications Model: UGT -IS602R Bus interface: PCI-Express 2.0 x 1 Ports: 2 x Internal SA T A 6G ports (Backward compatible with SA T A 3.
z 2 x SA T A Data Cable Layout Before Installing the V antec 2+1 SA T A 6G & P A T A PCI-E COMBO HOST CARD WITH RAID, please se e the ph oto below highlighting the available SA T A6G , IDE/P A T A ports of the card.
UGT ‐IS602R P a g e 5 Hardware Inst allation 1. T urn off the power to your computer . 2. Unplug the power cord and remove your computer’ s cover .
the virtual disk. Figure 1 Configuration W izard 2. Press Space to select/unselect a disk, as shown in Figure 2. Use the arrow keys to scroll the list of free disks.
Note: The 2+1 SA T A 6G & P A T A PCI-E COMBO HOST CARD WITH RAID supports the creation of RAID 0 and RAID 1 virtual disks comprising of exactly two SA T A physical disks. P A T A physical disks cannot be used to create RAID virtual d isks. 3. After selecting the requir ed disks, press Enter to continue, as shown in Figure 3.
4. Create V irtual Disk by configuring its setting in the Informatio n pane, as shown in Figure 4. The controls for making s election are listed i n the Help pane when an available setting is highlighted.
Note: Max size (MB) and Disk ID are properties of the virtual disk that cannot be edited. Max size (MB) in th e size of the RAID virtual disk as d etermined by the s elected RAID Level. Dis k ID lists the IDs of the physic al disks comprising the virtual disk.
Note: The def ault Level is RAID 0. 7. Scroll to S tripe Size and press Enter to select. A menu pops-up, as shown in Figure 6, and lists available stripe sizes for the sel ected RAID level.
Note: The defau lt size is 64 KB. 9. Scroll to Gigabyte Rounding and press Enter to select. A menu pops-up, as shown in Figure 7, and lists available stripe sizes for the sel ected RAID level.
Note: The defau lt setting for Gigabyte Rounding is 1G . 11. Scroll to Quick Init and press Enter to enable to disable quick initialization of the virtual disk. A menu pops-up, as shown in Figure 8, and lists available options for quick initialization of the vir tual disk.
Note: The def ault setting for Quick Init is Y es. 13. Scroll to VD Name and the Default nam e is cleared for a new name, as shown in Figure 9. T ype a new name and press Enter to confirm the selection.
14. After configuring the virtu al disk, scroll to Next , as shown in Figure 10. Press Enter to create the v irtual disk. Figure 10 Cr eate V irtual Disk UGT ‐IS602R .
15. Please Y to select Ye s , as shown in Figure 1 1, to confirm the creation of the virtual disk. Th e virtual disk is now listed in the T opology pane, as shown in Figure 12.
Figure 12 Virtual Disk in T opology Pane UGT ‐IS602R P a g e 1 6 .
UGT ‐IS602R P a g e 1 7 Managing V irtual Disks This section cont.
Erasing RAID Configurati on Data Note : The RAID controller stores RA ID configuration data on all physical disks that are part of a vi rtual disk. RAID configuration data must be erased on the physical disk before it can be used with another virtual disk.
Figure 14 Erase RAID Configuration Data Rebuilding V irtual Disk Note : The 2+1 SA T A 6G & P A T A PCI-E COMBO HOST CARD WITH RAID BIOS supports manual rebuilding of RAID 1 virtual disks. The rebuild process is both initiated and complete in the BIOS.
changed from Functional to Degrade , as shown in Figure 15 . Figure 15 Virtual Disk Pr operties: Degrade VD 2. Replace the faulty physical disk with an identical physical disk.
3. In the T opology pane , scroll to V irtual Disks (VD 0: New_VD in Figure 17), and press Enter to select. A menu pops-up, as shown in Figure 17 Scroll to Rebuild and press Enter to configure the rebuild process.
4. Scroll through the list of free di sk, as shown Figure 18, and pres s Space to select or unsele ct a replacement ph ysical disk. Press Enter to continue.
UGT ‐IS602R P a g e 2 3 5. Press Y to select Ye s , as shown in Figure 19, when prompted to confirm the rebuild process.
6. The status of the Rebuild process is reflected in the properties of the virtual disk, as shown in Figure 20. Figure 20 Rebuild S tatus T o pause the rebuild process 1. In the T opology pane, scroll to the par tially rebuil d Vi r t u a l D i s k . 2.
UGT ‐IS602R P a g e 2 5 T o pause the rebuild process 1. In the T opology pane, scroll to the par tially rebuil d Vi r t u a l D i s k .
Driver Inst allation Note: Driver can also be found and downloaded from our website at www .vantecusa.com For W indows® XP/Server 2003 UGT ‐IS602R .
UGT ‐IS602R P a g e 2 7 below . 1. Follow Microsoft’ s W indows installation procedure. 2. At the W indows Setup screen, press F6 to install the driver .
UGT ‐IS602R P a g e 2 8 OK . (Change D: to match your CD-ROM drive letter) 14. Follow the on-screen instructions to com plete the installation.
UGT ‐IS602R P a g e 2 9 below . 1. Follow Microsoft’ s W indows installation procedure. 2. At the W indows Setup screen, press F6 to install the driver .
UGT ‐IS602R P a g e 3 0 OK . (Change D: to match your CD-ROM drive letter) 14. Follow the on-screen instructions to com plete the installation.
UGT ‐IS602R P a g e 3 1 3.
UGT ‐IS602R P a g e 3 2 For An Existing Installation 1. Please insert the CD driver bound with 2+1 SA T A 6G & P A T A PCI-E COMBO HOST CARD WITH RAID into your CD-ROM Drive.
UGT ‐IS602R P a g e 3 3 F letter) 4. Continue with W indows OS installation. 5. And there is an additional d evice Marvell 91xx Config S CSI Processo r Device is detected w hen W indows starts for the first time.
UGT ‐IS602R P a g e 3 4 3. T ype D:UGT -IS602RXP_2003_V ista_2008_7Setup.exe , click OK . (Change D: to match your CD-ROM drive letter) 4.
UGT ‐IS602R P a g e 3 5 .
UGT ‐IS602R P a g e 3 6 W arranty The 2+1 SA T A 6G & P A T A PCI-E COMBO HOST CARD WITH RAID comes with a 1 year limited warranty(90 day parts).
デバイスVantec UGT-IS602Rの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Vantec UGT-IS602Rをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはVantec UGT-IS602Rの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Vantec UGT-IS602Rの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Vantec UGT-IS602Rで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Vantec UGT-IS602Rを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はVantec UGT-IS602Rの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Vantec UGT-IS602Rに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちVantec UGT-IS602Rデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。