Vermont Castingメーカー2547CEの使用説明書/サービス説明書
ページ先へ移動 of 28
Encore Multi-Fuel Heater Model 2547CE Homeowner ’ s Installation and Operating Manual SAFETY NOTICE: IF THIS APPLIANCE IS NOT PROPERL Y INST ALLED, OPERA TED AND MAIN- T AINED, A HOUSE FIRE MA Y RESUL T . TO REDUCE THE RISK OF FIRE, FOLLOW THE INST ALLA TION INSTRUCTIONS.
2 Encore Multi-Fuel Heater 2000971 Congratulations on your choice of a V ermont Castings Encore Multi-Fuel Heater . With this purchase you have made a commitment to make the hearth a place of warmth, beauty , and comfort in your home. At CFM Corporation, we share that joy and appreciation for the hearth.
3 Encore Multi-Fuel Heater 2000971 Specifications 51 mm (2") 641 mm (25 ") T op exit flue collar height 686 mm (27") 657 mm (25 ") 470 mm (18 ").
4 Encore Multi-Fuel Heater 2000971 SAFETY NOTICE: IF YOUR ENCORE IS NOT PROP- ERL Y INST ALLED, A HOUSE FIRE MA Y RESUL T . TO REDUCE THE RISK OF FIRE, FOLLOW THE INST ALLA TION INSTRUCTIONS. CONT ACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRIC- TIONS AND INST ALLA TION INSPECTION REQUIRE- MENTS IN YOUR AREA.
5 Encore Multi-Fuel Heater 2000971 ST241 chimney types 12/13/99 djt ST241 A tile-lined masonry chimney A prefabricated double- wall insulated chimney Fig.
6 Encore Multi-Fuel Heater 2000971 sheet metal screws. The pre-drilled holes in the top of each section of chimney connector serve as guides when you drill 3 mm (1/8”) holes in the bottom of the next section. • Secure the chimney connector to the chimney .
7 Encore Multi-Fuel Heater 2000971 ST492 Defiant freestanding installation 1 1/00 Chimney Elbow Slip Pipe Standard Connector Oval to Round Adapter Flue Collar Thimble Flue Liner Flue ST492 Fig. 5 An exploded view of the chimney connection in a free- standing masonry installation.
8 Encore Multi-Fuel Heater 2000971 • The fireplace damper must be sealed to prevent room air from escaping up the flue. However , it must be possible to reopen the damper to inspect or clean the chimney .
9 Encore Multi-Fuel Heater 2000971 ST247 Rear exit floor dgrm 12/14/99 djt Wood framing requires pro- tection from radiant heat ST247e Fig. 1 1 Combustible supporting timbers may lie beneath fireplace hearths, reqireimg additional floor protection.
10 Encore Multi-Fuel Heater 2000971 in section 2 of Document J, all installations must comply with these requirements or with the relevant National or local building standards. Clearances to timber framed (studded) walls are in- cluded below . There are no specific minimum clearanc- es to solid noncombustible surfaces (e.
1 1 Encore Multi-Fuel Heater 2000971 Set Up Y our Stove Cast iron stoves are heavy , and it will take two to four people to move your Encore MF into position. W ash the protective coating of oil from the griddle with soap and water . Dry the griddle thoroughly and apply a light coating of vegetable oil to season the surface and help prevent rust.
12 Encore Multi-Fuel Heater 2000971 ST638 Encore damper control 2/01 Damper Positions Open (Updraft Mode) Closed (Bypass Mode) ST638 Fig. 20 The damper is either open or closed.
13 Encore Multi-Fuel Heater 2000971 T wo W ays to Add Fuel The Encore’s griddle lifts for convenient top-loading of fuel, and is the easiest way to regularly add fuel. In addition, however , the front doors open for adding an occasional log to a fire.
14 Encore Multi-Fuel Heater 2000971 on Page 17 to see how the size, type, and location of your chimney will affect your stove operation. When thermometer readings drop below 175° C (350° F) it’s time to adjust the air control for a higher burn rate or to reload the stove.
15 Encore Multi-Fuel Heater 2000971 up” a fire. Keep all such liquids well away from the Encore while it is in use. 3. Light the newspaper and close the door .
16 Encore Multi-Fuel Heater 2000971 recommended only to add briquettes to the level of the front grate. 4. Close the damper . 5. When the surface temperature reaches 230° C (450° F), adjust the air control for the amount of heat you desire.
17 Encore Multi-Fuel Heater 2000971 A stove is part of a system, which includes the chimney , the operator , the fuel, and the home. The other parts of the system will affect how well the stove works. When there is a good match between all the parts, the system works well.
18 Encore Multi-Fuel Heater 2000971 Creosote Creosote is a by-product of slow wood-burning. It’s an organic tar that can condense in the flue if it’s dense in the smoke, and slow-moving, and cools off to less than 143° C (290° F). Condensed creosote is volatile, and can generate chimney fires if it gets hot enough.
19 Encore Multi-Fuel Heater 2000971 Maintenance Below you will find important information on general care, inspection and maintenance of your V ermont Castings stove.
20 Encore Multi-Fuel Heater 2000971 ST642 Encore damper adjust 3/01 Damper Lock Nut Pressure Adjust - ing Screw ST642 Fig. 31 Adjusting the damper . ST641 Encore air shutter 3/01 Primary Air Shutter ST641 Fig. 30 The primary air shutter must move freely .
21 Encore Multi-Fuel Heater 2000971 ST531 Door Pawl 1 1/00 Pawl Small Locking Nut Large Lock- ing Nut Set Screw Handle Stub Striker Screw ST531 Fig. 32 T urn the door latch striker screw in or out to tighten or loosen the door latch.
22 Encore Multi-Fuel Heater 2000971 Clean the chimney connector by disconnecting the sec- tions, taking them outside, and removing any deposits with a stiff wire brush. Reinstall the connector sections after cleaning, being sure to secure the joints between individual sections with sheet metal screws.
23 Encore Multi-Fuel Heater 2000971 1 3 2 4 5 6 7 8 9 12 9 19 14 15 16 17 18 20 21 22 24 25 27 28 29 31 32 33 34 35 46 47 48 49 36 37 38 39 40 41 42 43 44 45 50 53 54 58 56 55 61 60 33 13 13 57 59 57 .
24 Encore Multi-Fuel Heater 2000971 Encore Multi-Fuel Heater Model 2547CE (continued) Item Description Part Number Item Description Part Number 7. Griddle Handle Assembly 5004022 8. T op See Chart Pg. 28 9. Wedge (2) 1301810 10. Upper Fireback 1 1308639 1 1.
25 Encore Multi-Fuel Heater 2000971 Shell Enamel Parts - Encore Multi-Fuel Model 2547CE Part Name Classic Green Moonlight Sand Red Blue T op 1308618 2318618 2378618 1328618 2328618 1338618 Left Side 1.
26 Encore Multi-Fuel Heater 2000971.
27 Encore Multi-Fuel Heater 2000971 W arranty Limited 3 Y ear W arranty CFM Corporation warrants that this woodburning stove will be free of defects in material and workmanship for a period of three y.
410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 800-668-5323 • www .cfmcorp.com CFM Corporation.
デバイスVermont Casting 2547CEの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Vermont Casting 2547CEをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはVermont Casting 2547CEの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Vermont Casting 2547CEの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Vermont Casting 2547CEで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Vermont Casting 2547CEを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はVermont Casting 2547CEの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Vermont Casting 2547CEに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちVermont Casting 2547CEデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。